<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">OJSST</journal-id><journal-title-group><journal-title>Open Journal of Safety Science and Technology</journal-title></journal-title-group><issn pub-type="epub">2162-5999</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ojsst.2017.71001</article-id><article-id pub-id-type="publisher-id">OJSST-74184</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject><subject> Earth&amp;Environmental Sciences</subject><subject> Engineering</subject><subject> Physics&amp;Mathematics</subject><subject> Social Sciences&amp;Humanities</subject></subj-group></article-categories><title-group><article-title>
 
 
  The Measurement and Prediction of Flash Point for Binary Mixtures {C&lt;sub&gt;1&lt;/sub&gt; ~ C&lt;sub&gt;3&lt;/sub&gt; Alcohols + &lt;i&gt;p&lt;/i&gt;-Xylene} at 101.3 kPa
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Kyu</surname><given-names>Jin Han</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Se</surname><given-names>Jin In</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Department of Ammunitions, Daeduk College, Daejeon, Republic of Korea</addr-line></aff><aff id="aff2"><addr-line>Department of Fire and Disaster Protection Engineering, Woosong University, Daejeon, Republic of Korea</addr-line></aff><pub-date pub-type="epub"><day>16</day><month>02</month><year>2017</year></pub-date><volume>07</volume><issue>01</issue><fpage>1</fpage><lpage>10</lpage><history><date date-type="received"><day>December</day>	<month>20,</month>	<year>2016</year></date><date date-type="rev-recd"><day>Accepted:</day>	<month>February</month>	<year>13,</year>	</date><date date-type="accepted"><day>February</day>	<month>16,</month>	<year>2017</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  The flash point of flammable liquid mixture is very important parameter to characterize the ignition and explosion hazards. Flash points at 101.3 kPa were measured for several binary systems containing 
  <em>p</em>-xylene, including {methanol + 
  <em>p</em>-xylene}, {ethanol + 
  <em>p</em>-xylene}, and {2-propanol and 
  <em>p</em>-xylene}. Experimental measurements were performed using a SETA closed cup flash point tester. The measured flash points were compared with the predicted values calculated using the following activity coefficient models: Wilson, Non-Random Two Liquid (NRTL), and UNIversal QUAsi-Chemical (UNIQUAC). The results from the NRTL model provided the best comparison to the experimentally determined values.
 
</p></abstract><kwd-group><kwd>Flash Point</kwd><kwd> SETA Closed Cup Flash Point Tester</kwd><kwd> Binary Mixtures</kwd><kwd> Activity Coefficient Models</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Flammable substances, such as organic solvents, are commonly used in laboratories and industrial processes. The flash point (FP) is one of the most important parameters used to characterize the ignition and explosion hazards of these liquids [<xref ref-type="bibr" rid="scirp.74184-ref1">1</xref>] . The lower flammable limit (LFL) provides information on the fundamental physical and chemical processes of combustion. The FP of a given liquid can be experimentally determined, and the resulting temperature may then be adjusted to the standard sea level atmospheric pressure of 101.3 kPa, the pressure at which a substance emits sufficient vapor to form a combustible mixture with air [<xref ref-type="bibr" rid="scirp.74184-ref2">2</xref>] .</p><p>As the temperature increases, there is a concomitant increase in both the vapor pressure and the amount of evaporated, flammable liquid in equilibrium with the air. When the temperature is reached at FP, a simple ignition source is able to combust the vapor mixture [<xref ref-type="bibr" rid="scirp.74184-ref3">3</xref>] . Experimental FP data for the multi- component mixtures have become important in ensuring safe storage of flammable materials and, for this reason, studies for predicting the FP of pure substances and mixtures are increasingly important.</p><p>Benzene, toluene and xylene are the most used solvents in the rubber products such as tire manufacturing, rubber bands, rubber gloves and appliance moldings. The several alcohols and their mixtures are very useful in the rubber industry [<xref ref-type="bibr" rid="scirp.74184-ref4">4</xref>] [<xref ref-type="bibr" rid="scirp.74184-ref5">5</xref>] . The most common of these solvents is xylene which is used as a solvent in the manufacturing of chemicals, tires, agricultural sprays, adhesives and coatings, as an ingredient in aviation fuel and gasoline, and as a feedstock in manufacturing various polymers, including phthalic anhydride, isophthalic acid, terephthalic acid and dimethyl terephthalate [<xref ref-type="bibr" rid="scirp.74184-ref6">6</xref>] . The purpose of this study is to determine the FPs for flammable binary mixtures commonly used as industrial solvents such as alcohols and xylene.</p><p>In the present work, the FPs at 101.3 kPa were determined using a SETA closed cup flash point tester on the following solvent mixtures: {methanol (1) + p-xylene (2)}, {ethanol (1) + p-xylene (2)} and {2-propanol (1) + p-xylene (2)}. The measured FP data for these binary systems were compared with predicted values from a variety of local composition activity coefficient models, including the Wilson, Non-Random Two-Liquid (NRTL) and UNIversalQUAsiChemical (UNIQUAC)models [<xref ref-type="bibr" rid="scirp.74184-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.74184-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.74184-ref9">9</xref>] .</p></sec><sec id="s2"><title>2. Material and Methods</title><sec id="s2_1"><title>2.1. Materials</title><p>Commercial, analytical-grade chemicals were used in this investigation. p-Xylene (C<sub>8</sub>H<sub>10</sub>, M = 106.17 g·mol<sup>−1</sup>, CAS-RN 106-42-3, 99.9 %) was obtained from Fluka Co. Methanol (CH<sub>4</sub>O, M = 32.04 gmol<sup>−1</sup>, CAS-RN 67-56-1, 99.9%), Ethanol (C<sub>2</sub>H<sub>6</sub>O, M = 46.07 gmol<sup>−1</sup>, CAS-RN 64-17-5, 99.9%) and 2-propanol (C<sub>3</sub>H<sub>8</sub>O, M = 60.10 g·mol<sup>−1</sup>, CAS-RN 67-63-0, 99.9%) were supplied by J. T. Baker Chemical Co. All of the chemicals were dried using molecular sieves with a pore diameter of 0.4 nm. The water contents of the chemicals were determined by Karl-Fischer titration (using a Metrohm 684 KF-Coulometer) and were found to be less than 6 &#180; 10<sup>−5</sup> g/g. The purities of the chemicals were assessed by gas chromatography. The reported values for the purities, FPs and UNIQUAC parameters [<xref ref-type="bibr" rid="scirp.74184-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.74184-ref11">11</xref>] are listed in <xref ref-type="table" rid="table1">Table 1</xref>.</p></sec><sec id="s2_2"><title>2.2. Procedure</title><p>A SETA closed cup flash point tester (Series 8 SETAFLASH, model 82000-0, Surrey, UK) was used to measure the FPs for the miscible mixture samples. The SETA closed cup flash point tester was operated according to the standard test method, ASTM D 3278 [<xref ref-type="bibr" rid="scirp.74184-ref12">12</xref>] . Detailed descriptions for the measuring system and</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> The purities and UNIQUAC parameters of chemicals used in this work</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Chemicals</th><th align="center" valign="middle"  rowspan="2"  >G.C. analysis (wt %)</th><th align="center" valign="middle"  colspan="2"  >Flash Point (K) at 101.3 kPa</th><th align="center" valign="middle"  colspan="2"  >UNIQUAC</th></tr></thead><tr><td align="center" valign="middle" >This work</td><td align="center" valign="middle" >Reference<sup>a</sup></td><td align="center" valign="middle" >r-value<sup>b</sup></td><td align="center" valign="middle" >q-value<sup>b</sup></td></tr><tr><td align="center" valign="middle" >Methanol</td><td align="center" valign="middle" >&gt;99.9</td><td align="center" valign="middle" >283.45</td><td align="center" valign="middle" >284.15</td><td align="center" valign="middle" >1.4311</td><td align="center" valign="middle" >1.4320</td></tr><tr><td align="center" valign="middle" >Ethanol</td><td align="center" valign="middle" >&gt;99.9</td><td align="center" valign="middle" >286.65</td><td align="center" valign="middle" >286.15</td><td align="center" valign="middle" >2.1055</td><td align="center" valign="middle" >1.9720</td></tr><tr><td align="center" valign="middle" >2-propanol</td><td align="center" valign="middle" >&gt;99.9</td><td align="center" valign="middle" >286.85</td><td align="center" valign="middle" >285.15</td><td align="center" valign="middle" >2.7791</td><td align="center" valign="middle" >2.5080</td></tr><tr><td align="center" valign="middle" >p-xylene</td><td align="center" valign="middle" >&gt;99.9</td><td align="center" valign="middle" >298.45</td><td align="center" valign="middle" >300.15</td><td align="center" valign="middle" >4.6578</td><td align="center" valign="middle" >3.5360</td></tr></tbody></table></table-wrap><p><sup>a</sup>Ref [<xref ref-type="bibr" rid="scirp.74184-ref10">10</xref>] ; <sup>b</sup>Ref [<xref ref-type="bibr" rid="scirp.74184-ref11">11</xref>] .</p><p>procedure can be found in the previous work [<xref ref-type="bibr" rid="scirp.74184-ref13">13</xref>] [<xref ref-type="bibr" rid="scirp.74184-ref14">14</xref>] . Mixture samples for the experiments were weighed using a microbalance (Ohaus DV215CD) with a precision of 1 &#180; 10<sup>−5</sup> g. Further details are also appeared in elsewhere [<xref ref-type="bibr" rid="scirp.74184-ref13">13</xref>] [<xref ref-type="bibr" rid="scirp.74184-ref14">14</xref>] .</p></sec></sec><sec id="s3"><title>3. Results and Discussion</title><p>Le Chatelier’s rule [<xref ref-type="bibr" rid="scirp.74184-ref15">15</xref>] for a mixture of flammable vapor and air may be expressed as follows:</p><disp-formula id="scirp.74184-formula1"><label>(1)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-1480172x2.png"  xlink:type="simple"/></disp-formula><p>where y<sub>i</sub> is the vapor phase composition of a flammable substance i and LFL<sub>i</sub> is the lower flammable limit of the pure component i. The LFL<sub>i</sub> is expressed in relation to the pure component i vapor pressure at its FP, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-1480172x3.png" xlink:type="simple"/></inline-formula>, as</p><disp-formula id="scirp.74184-formula2"><label>(2)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-1480172x4.png"  xlink:type="simple"/></disp-formula><p>where P represents the ambient pressure. The FP of a pure substance is typically measured at standard atmospheric pressure. Under this condition, the vapor phase can be assumed with behaving ideally. With the non-ideal liquid phase containing flammable substances in the presence of the non-condensable components of air, the vapor?liquid equilibrium of component i is described by the modified Raoult’s law:</p><disp-formula id="scirp.74184-formula3"><label>(3)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-1480172x5.png"  xlink:type="simple"/></disp-formula><p>where γ<sub>i</sub> is activity coefficient for the liquid phase.</p><p>As proposed by Liaw et al. [<xref ref-type="bibr" rid="scirp.74184-ref16">16</xref>] , one can substitute Equation (2) and Equation (3) into Equation (1), resulting in Equation (4), which allows evaluation of FPs for flammable liquid mixtures:</p><disp-formula id="scirp.74184-formula4"><label>(4)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-1480172x6.png"  xlink:type="simple"/></disp-formula><p>The saturated vapor pressure for a pure substance i can be obtained by the Antoine Equation [<xref ref-type="bibr" rid="scirp.74184-ref17">17</xref>] :</p><disp-formula id="scirp.74184-formula5"><label>(5)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-1480172x7.png"  xlink:type="simple"/></disp-formula><p>Antoine constants (A, B and C in Equation (5)) were adapted from the literature [<xref ref-type="bibr" rid="scirp.74184-ref11">11</xref>] and are given in <xref ref-type="table" rid="table2">Table 2</xref>.</p><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> The Antoine constants of the pure components</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Components</th><th align="center" valign="middle"  colspan="3"  >Antoine coefficients<sup>a</sup></th></tr></thead><tr><td align="center" valign="middle" >A</td><td align="center" valign="middle" >B</td><td align="center" valign="middle" >C</td></tr><tr><td align="center" valign="middle" >Methanol</td><td align="center" valign="middle" >8.08097</td><td align="center" valign="middle" >1582.27</td><td align="center" valign="middle" >239.726</td></tr><tr><td align="center" valign="middle" >Ethanol</td><td align="center" valign="middle" >8.11220</td><td align="center" valign="middle" >1592.86</td><td align="center" valign="middle" >226.184</td></tr><tr><td align="center" valign="middle" >2-propanol</td><td align="center" valign="middle" >8.00308</td><td align="center" valign="middle" >1505.52</td><td align="center" valign="middle" >211.600</td></tr><tr><td align="center" valign="middle" >p-xylene</td><td align="center" valign="middle" >6.99053</td><td align="center" valign="middle" >1453.43</td><td align="center" valign="middle" >215.300</td></tr></tbody></table></table-wrap><p><sup>a</sup>Ref [<xref ref-type="bibr" rid="scirp.74184-ref11">11</xref>] .</p><p>Assuming the solution behave ideally, the activity coefficients of the liquid phase are equal to unity. Therefore, Equation (4) was reduced according to Raoult’s law and expressed as [<xref ref-type="bibr" rid="scirp.74184-ref14">14</xref>] :</p><disp-formula id="scirp.74184-formula6"><label>(6)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-1480172x8.png"  xlink:type="simple"/></disp-formula><p>The temperature that satisfies Equation (6) is obtained to be the flash point of the ideal solution.</p><p>For non-ideal liquid mixtures, activity coefficients (γ<sub>i</sub>) were estimated with the optimum binary interaction parameters of the Wilson, NRTL and UNIQUAC equations, described below [<xref ref-type="bibr" rid="scirp.74184-ref6">6</xref>] [<xref ref-type="bibr" rid="scirp.74184-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.74184-ref8">8</xref>] .</p><p>Wilson Equation:</p><disp-formula id="scirp.74184-formula7"><label>(7)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-1480172x9.png"  xlink:type="simple"/></disp-formula><p>with</p><disp-formula id="scirp.74184-formula8"><graphic  xlink:href="http://html.scirp.org/file/1-1480172x10.png"  xlink:type="simple"/></disp-formula><p>NRTL Equation:</p><disp-formula id="scirp.74184-formula9"><label>(8)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-1480172x11.png"  xlink:type="simple"/></disp-formula><p>with</p><disp-formula id="scirp.74184-formula10"><graphic  xlink:href="http://html.scirp.org/file/1-1480172x12.png"  xlink:type="simple"/></disp-formula><p>UNIQUAC Equation:</p><disp-formula id="scirp.74184-formula11"><label>(9)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-1480172x13.png"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.74184-formula12"><graphic  xlink:href="http://html.scirp.org/file/1-1480172x14.png"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.74184-formula13"><graphic  xlink:href="http://html.scirp.org/file/1-1480172x15.png"  xlink:type="simple"/></disp-formula><p>with</p><disp-formula id="scirp.74184-formula14"><graphic  xlink:href="http://html.scirp.org/file/1-1480172x16.png"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.74184-formula15"><graphic  xlink:href="http://html.scirp.org/file/1-1480172x17.png"  xlink:type="simple"/></disp-formula><p>The binary parameters used to calculate the activity coefficients were taken from the references and are provided in <xref ref-type="table" rid="table3">Table 3</xref> [<xref ref-type="bibr" rid="scirp.74184-ref18">18</xref>] [<xref ref-type="bibr" rid="scirp.74184-ref19">19</xref>] .</p><p>The experimental binary FP data for the three systems tested as part of this work, {methanol + p-xylene}, {ethanol + p-xylene} and {2-propanol + p-xylene}, are given in <xref ref-type="table" rid="table4">Table 4</xref>. The experimentally determined binary data were compared with the predicted values from the Wilson, NRTL and UNIQUAC models. The binary parameters of each model equation were used to calculate the activity coefficients of liquid mixture under the same conditions employed in the experiments, and the initial temperature for calculation was assigned the numerical average FP of the pure components. Then, the FP was obtained from adjustment of initial temperature by satisfying the Le Chatelier’s rule (Equation 4). The objective function (OF) used was</p><disp-formula id="scirp.74184-formula16"><label>(10)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-1480172x18.png"  xlink:type="simple"/></disp-formula><p>The average absolute deviations (A.A.D) between the measured and calculated values are included in <xref ref-type="table" rid="table4">Table 4</xref>.</p><p>A.A.D is defined as:</p><disp-formula id="scirp.74184-formula17"><label>(11)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-1480172x19.png"  xlink:type="simple"/></disp-formula><p>where <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-1480172x20.png" xlink:type="simple"/></inline-formula> is the experimentally determined FP of component i, and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-1480172x20.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-1480172x21.png" xlink:type="simple"/></inline-formula> is the predicted FP of component i.</p><p>The data of each binary system at 101.3 kPa pressure are plotted in Figures 1- 3. The parameters for the activity coefficient models are given in <xref ref-type="table" rid="table3">Table 3</xref>, along with the A.A.D between the experimental and predicted values. All FP data agreed very well, as illustrated in the figures. Minimum flash point behavior was</p><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> The optimized binary parameters of the Wilson, NRTL and UNIQUAC equa- tions for each binary system</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Systems</th><th align="center" valign="middle"  colspan="3"  >Wilson</th><th align="center" valign="middle"  colspan="3"  >NRTL</th><th align="center" valign="middle"  colspan="3"  >UNIQUAC</th></tr></thead><tr><td align="center" valign="middle" >A<sub>12</sub>/<sub> </sub> J・mol<sup>−1</sup></td><td align="center" valign="middle" >A<sub>21</sub>/<sub> </sub> J・mol<sup>−1</sup></td><td align="center" valign="middle"  colspan="2"  >A<sub>12</sub><sub>/ </sub> J・mol<sup>−1</sup></td><td align="center" valign="middle" >A<sub>21</sub>/<sub> </sub> J・mol<sup>−1</sup></td><td align="center" valign="middle"  colspan="2"  >α</td><td align="center" valign="middle" >A<sub>12</sub>/<sub> </sub> J・mol<sup>−1</sup></td><td align="center" valign="middle" >A<sub>21</sub>/<sub> </sub> J・mol<sup>−1</sup></td></tr><tr><td align="center" valign="middle" >{Methanol (1) + p-xylene (2)}<sup>a</sup></td><td align="center" valign="middle" >8528.95</td><td align="center" valign="middle" >1351.52</td><td align="center" valign="middle"  colspan="2"  >4919.00</td><td align="center" valign="middle" >5586.05</td><td align="center" valign="middle"  colspan="2"  >0.4910</td><td align="center" valign="middle" >−571.78</td><td align="center" valign="middle" >6100.37</td></tr><tr><td align="center" valign="middle" >{Ethanol (1) + p-xylene (2)}<sup>a</sup></td><td align="center" valign="middle" >7331.13</td><td align="center" valign="middle" >857.87</td><td align="center" valign="middle"  colspan="2"  >3585.84</td><td align="center" valign="middle" >5226.78</td><td align="center" valign="middle"  colspan="2"  >0.5257</td><td align="center" valign="middle" >−898.74</td><td align="center" valign="middle" >4480.60</td></tr><tr><td align="center" valign="middle" >{2-propanol (1) + p-xylene (2)}<sup>b</sup></td><td align="center" valign="middle" >6014.68</td><td align="center" valign="middle" >1322.93</td><td align="center" valign="middle"  colspan="2"  >2963.21</td><td align="center" valign="middle" >4543.33</td><td align="center" valign="middle"  colspan="2"  >0.5095</td><td align="center" valign="middle" >−582.39</td><td align="center" valign="middle" >2798.40</td></tr><tr><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr></tbody></table></table-wrap><p><sup>a</sup>Ref [<xref ref-type="bibr" rid="scirp.74184-ref18">18</xref>] ; <sup>b</sup>Ref [<xref ref-type="bibr" rid="scirp.74184-ref19">19</xref>] .</p><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> The experimental and predicted FPs for each binary system at 101.3 kPa</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Mole factions</th><th align="center" valign="middle"  colspan="5"  >Flash points (K)</th></tr></thead><tr><td align="center" valign="middle"  rowspan="2"  >x<sub>1</sub></td><td align="center" valign="middle"  rowspan="2"  >Experimental value</td><td align="center" valign="middle"  colspan="4"  >Predicted value</td></tr><tr><td align="center" valign="middle" >Raoult’s law</td><td align="center" valign="middle" >Wilson</td><td align="center" valign="middle" >NRTL</td><td align="center" valign="middle" >UNIQUAC</td></tr><tr><td align="center" valign="middle"  colspan="6"  >{Methanol (1) + p-xylene (2)}</td></tr><tr><td align="center" valign="middle" >0.0000 0.0501 0.1059 0.2443 0.2983 0.4012 0.5102 0.6122 0.7010 0.8002 0.8996 0.9499 1.0000</td><td align="center" valign="middle" >298.45 285.75 283.25 281.35 281.05 280.65 280.55 280.45 280.35 280.45 280.85 281.65 283.45</td><td align="center" valign="middle" >- 297.37 296.22 293.62 292.69 291.02 289.40 287.99 286.85 285.65 284.52 283.98 -</td><td align="center" valign="middle" >- 283.72 281.54 280.56 280.45 280.32 280.23 280.16 280.12 280.16 280.57 281.31 -</td><td align="center" valign="middle" >- 284.02 281.72 281.00 280.87 280.57 280.29 280.11 280.04 280.05 280.30 280.94 -</td><td align="center" valign="middle" >- 284.57 281.51 280.51 280.57 280.72 280.77 280.73 280.70 280.79 281.36 282.08 -</td></tr><tr><td align="center" valign="middle" >A.A.D</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >8.45</td><td align="center" valign="middle" >0.66</td><td align="center" valign="middle" >0.59</td><td align="center" valign="middle" >0.60</td></tr><tr><td align="center" valign="middle"  colspan="6"  >{Ethanol (1) + p-xylene (2)}</td></tr><tr><td align="center" valign="middle" >0.0000 0.0506 0.0980 0.1972 0.3005 0.3985 0.5000 0.5967 0.6992 0.7995 0.8998 0.9497 1.0000</td><td align="center" valign="middle" >298.45 288.15 286.15 285.05 284.65 284.25 283.95 283.65 283.45 283.55 284.05 284.75 286.65</td><td align="center" valign="middle" >- 297.56 296.77 295.24 293.80 292.56 291.37 290.33 289.30 288.36 287.48 287.06 -</td><td align="center" valign="middle" >- 287.33 285.44 284.39 284.04 283.86 283.72 283.62 283.59 283.75 284.39 285.16 -</td><td align="center" valign="middle" >- 287.43 285.49 284.60 284.26 283.98 283.75 283.59 283.54 283.64 284.16 284.91 -</td><td align="center" valign="middle" >- 287.82 285.35 284.17 284.10 284.12 284.08 284.01 284.01 284.24 284.95 285.62 -</td></tr><tr><td align="center" valign="middle" >A.A.D</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >7.11</td><td align="center" valign="middle" >0.41</td><td align="center" valign="middle" >0.29</td><td align="center" valign="middle" >0.56</td></tr><tr><td align="center" valign="middle"  colspan="6"  >{2-propanol (1) + p-xylene (2)}</td></tr><tr><td align="center" valign="middle" >0.0000 0.0491 0.1016 0.2018 0.2993 0.4006 0.4982 0.5996 0.7003 0.8065 0.8958 0.9461 1.0000</td><td align="center" valign="middle" >298.45 289.25 288.05 286.45 285.55 285.35 284.95 284.75 284.45 284.35 284.95 285.55 286.85</td><td align="center" valign="middle" >- 297.53 296.62 295.04 293.69 292.42 291.32 290.27 289.31 288.38 287.65 287.26 -</td><td align="center" valign="middle" >- 288.75 286.40 285.11 284.69 284.45 284.30 284.19 284.16 284.33 284.86 285.53 -</td><td align="center" valign="middle" >- 288.82 286.51 285.17 284.75 284.51 284.31 284.19 284.15 284.28 284.83 285.51 -</td><td align="center" valign="middle" >- 289.92 287.15 285.19 284.72 284.59 284.51 284.44 284.42 284.60 285.24 285.86 -</td></tr><tr><td align="center" valign="middle" >A.A.D</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >5.98</td><td align="center" valign="middle" >0.63</td><td align="center" valign="middle" >0.52</td><td align="center" valign="middle" >0.85</td></tr></tbody></table></table-wrap><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> The comparison of the flash point prediction curves with the experimental data for the binary system {methanol (1) + p-xylene (2)} at 101.3 kPa</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1480172x22.png"/></fig><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> The comparison of the flash point prediction curves with the experimental data for the binary system {ethanol (1) + p-xylene (2)} at 101.3 kPa</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1480172x23.png"/></fig><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> The comparison of the flash point prediction curves with the experimental data for the binary system {2-propanol (1) + p-xylene (2)} at 101.3 kPa</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1480172x24.png"/></fig><p>observed in all the binaries. Minimum flash point is caused from minimum boiling azeotrope in vapor-liquid equilibrium of the mixture. Moreover, the minimum flash point behavior values of each binary system were estimated using the best fitted model, NRTL. They are x<sub>1</sub> = 0.745, T = 280.03 K for the system {methanol + p-xylene}, x<sub>1</sub> = 0.693, T = 283.54 K for the system {ethanol + p-xylene} and x<sub>1</sub> = 0.683, T = 284.14 K for the system {2-propanol + p-xylene}.</p><p>For the investigated systems, the A.A.D between the predicted and measured FP values were less than 0.85 K, except when calculated by Raoult’s law. Among the models, the NRTL model yielded results closest to the experimentally determined values. The minimum values of A.A.D by NRTL are 0.59, 0.29 and 0.52 K for {methanol + p-xylene}, {ethanol + p-xylene} and {2-propanol + p-xylene}, respectively.</p></sec><sec id="s4"><title>4. Conclusion</title><p>Flash point data for {methanol + p-xylene}, {ethanol + p-xylene} and {2-pro- panol + p-xylene} binary systems were determined at atmospheric pressure. Minimum flash point behavior was observed in all three binaries. Moreover, the minimum flash point behavior values of each binary system were estimated using the best fitted model. The measured FP data agreed well with the predicted values derived from the Wilson, NRTL and UNIQUAC models, with the NRTL model providing the most comparable results. The average absolute deviations between the measured and predicted FPs were less than 0.85K.</p></sec><sec id="s5"><title>Cite this paper</title><p>Han, K.J. and In, S.J. (2017) The Measurement and Prediction of Flash Point for Binary Mixtures {C<sub>1</sub> ~ C<sub>3</sub> Alcohols + p-Xylene} at 101.3 kPa. Open Journal of Safety Science and Technology, 7, 1-10. https://doi.org/10.4236/ojsst.2017.71001</p></sec></body><back><ref-list><title>References</title><ref id="scirp.74184-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Crowl, D.A. and Louvar, J.F. (1990) Chemical Process Safety: Fundamentals with Applications. Prentice Hall, Englewood Cliffs, NY.</mixed-citation></ref><ref id="scirp.74184-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">CCPS/AIChE (1993) Guidelines for Safe Automation of Chemical Processes. American Institute of Chemical Engineering, New York.</mixed-citation></ref><ref id="scirp.74184-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Lees, F.P. (1996) Loss Prevention in the Process Industries. 2nd Edition, Butterworth-Heinemann, Oxford, UK.</mixed-citation></ref><ref id="scirp.74184-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Lawrence, F. (1990) Chemicals Used in the Rubber Industry. Springer, Berlin Heidelberg, 45-95.</mixed-citation></ref><ref id="scirp.74184-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Manuel, H.J. and Dierkes, W. (1997) Recycling of Rubber. Rapra Review Reports, 9, Report 99.</mixed-citation></ref><ref id="scirp.74184-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">US Environmental Protection Agency (1994) Locating and Estimating Air Emissions from Sources of Xylene. EPA-454-R-93-048.</mixed-citation></ref><ref id="scirp.74184-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Wilson, G.M. and Deal, C.H. (1962) Activity Coefficients and Molecular Structure. Activity Coefficients in Changing Environments-Solutions of Groups. Industrial &amp; Engineering Chemistry Fundamentals, 1, 20-23.  
https://doi.org/10.1021/i160001a003</mixed-citation></ref><ref id="scirp.74184-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Renon, H. and Prausnitz, J.M. (1968) Local Compositions in Thermodynamic Excess Functions for Liquid Mixtures. AIChE Journal, 14, 135-144.  
https://doi.org/10.1002/aic.690140124</mixed-citation></ref><ref id="scirp.74184-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Abrams, D.S. and Prausnitz, J.M. (1975) Statistical Thermodynamics of Liquid Mixtures: A New Expression for the Excess Gibbs Energy of Partly or Completely Miscible Systems. AIChE Journal, 21, 116-128.  
https://doi.org/10.1002/aic.690210115</mixed-citation></ref><ref id="scirp.74184-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">National Fire Protection Association (1985) Fire Investigations. Batterymarch Park, Quincy, MA., National Fire Codes, 7.</mixed-citation></ref><ref id="scirp.74184-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Dortmund Data Bank Software Package (DDBSP) Version 2006 Professional, Software and Separation Technology GmbH. http://www.ddbst.de</mixed-citation></ref><ref id="scirp.74184-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">American Society for Testing Materials (1999) Annual Book of ASTM Standards. 6.</mixed-citation></ref><ref id="scirp.74184-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">In, S.J. (2015) Flash Point for Binary MIXTURES of methylcyclohexane, n-Heptane and p-Xylene. Journal of Industrial and Engineering Chemistry, 32, 327-331.  
https://doi.org/10.1016/j.jiec.2015.09.013</mixed-citation></ref><ref id="scirp.74184-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Oh, I.S. and In, S.J. (2015) The Measurement and Prediction of Flash Point for Binary Mixtures of Methanol, Ethanol, 2-Propanol and 1-Butanol at 101.3 kPa. Fire Science and Engineering, 29, 1-6. https://doi.org/10.7731/KIFSE.2015.29.5.001</mixed-citation></ref><ref id="scirp.74184-ref15"><label>15</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Le Chatelier</surname><given-names> H. </given-names></name>,<etal>et al</etal>. (<year>1891</year>)<article-title>Estimation of Firedamp by Flammability Limits</article-title><source> Annales des Mines</source><volume> 19</volume>,<fpage> 388</fpage>-<lpage>395</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.74184-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Liaw, H.J., Tang, C.L. and Lai, J.S. (2004) A Model for Predicting the Flash Point of Ternary Flammable Solution of Liquid. Combust Flame, 138, 308-319.  
https://doi.org/10.1016/j.combustflame.2004.06.002</mixed-citation></ref><ref id="scirp.74184-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Poling, B.E., Prausnitz, J.M. and O’connell, J.P. (2001) The Properties of Gases and Liquids. 5th Edition, McGraw-Hill, New York.</mixed-citation></ref><ref id="scirp.74184-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Oracz, P. and Kolasinska, G. (1987) Vapour-Liquid Equilibria-III. Total Vapour Pressure Measurements for Binary Mixtures of Methanol, Ethanol, 1-Propanol and 1-Butanol with Benzene, Toluene and p-Xylene at 313.15 K. Fluid Phase Equilibria, 35, 253-278. https://doi.org/10.1016/0378-3812(87)80016-X</mixed-citation></ref><ref id="scirp.74184-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Gupta, V., Maken, S., Kalra, K.C. and Singh K.C. (1996) Molar Excdess Gibbs Free Energy of 1-Propanol or 2-Propanol + Aromatic Hydrocarbons at 298.15 K in terms of an Association Model with a Flory Contribution Term. Thermochimica Acta, 277, 187-198. https://doi.org/10.1016/0040-6031(95)02745-9</mixed-citation></ref></ref-list></back></article>