<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">ENG</journal-id><journal-title-group><journal-title>Engineering</journal-title></journal-title-group><issn pub-type="epub">1947-3931</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/eng.2015.77032</article-id><article-id pub-id-type="publisher-id">ENG-57570</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Connection between Concrete Layers with Different Strengths
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>ae</surname><given-names>Yoon Kang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jong</surname><given-names>Sup Park</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Woo</surname><given-names>Tai Jung</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Moon</surname><given-names>Seoung Keum</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Structural Engineering Research Institute, Korea Institute of Civil Engineering and Building Technology, 
Goyang, Republic of Korea</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>jykang@kict.re.kr(AYK)</email>;<email>jspark1@kict.re.kr(JSP)</email>;<email>woody@kict.re.kr(WTJ)</email>;<email>moonseoung@kict.re.kr(MSK)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>30</day><month>06</month><year>2015</year></pub-date><volume>07</volume><issue>07</issue><fpage>365</fpage><lpage>372</lpage><history><date date-type="received"><day>8</day>	<month>June</month>	<year>2015</year></date><date date-type="rev-recd"><day>accepted</day>	<month>15</month>	<year>June</year>	</date><date date-type="accepted"><day>30</day>	<month>June</month>	<year>2015</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  As part of a research intending to develop steel-concrete hybrid girder using ultra high performance concrete with compressive strength of 80 MPa, this study conducts loading test on this girder to investigate the methods for its composition with a slab using 30 MPa-concrete and the corresponding interfacial behavior. Prior to the loading test, the design formula of the Eurocode for the shear resistance developed in concrete-to-concrete interface is examined for the interface between concrete layers of different strengths. The effect of the surface roughness on the shear resistance is examined using this formula and finite element analysis to verify the applicability of the formula. Based upon the results, loading test is conducted on girder specimens to evaluate the actual behavior with respect to the interfacial surface condition. The test results reveal that the specimen with rough interface could not develop perfectly composite behavior and experienced adhesive failure. In case of simultaneous action of flexure and shear, it appears that conservative design should be applied without consideration of the interfacial condition when determining the arrangement of shear reinforcement.
 
</p></abstract><kwd-group><kwd>Shear Resistance</kwd><kwd> Interface between Concrete Layers</kwd><kwd> Surface Roughness</kwd><kwd> Steel-Concrete Hybrid Girder</kwd><kwd> Ultra High Performance Concrete (UHPC)</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>The transfer mechanism of the shear stress developed in a member combining concrete layers with different strengths is very complicated. This mechanism is subordinate to the effect of various parameters like the amount of reinforcing steel traversing the interface, the compressive resistance of the lower strength concrete, the degree of roughness of the interface, and the stress provoked by the vertical load. Research on this mechanism started in 1960s like the works of Hanson [<xref ref-type="bibr" rid="scirp.57570-ref1">1</xref>] , Birkeland and Birkeland [<xref ref-type="bibr" rid="scirp.57570-ref2">2</xref>] , Mattock and Hawkins [<xref ref-type="bibr" rid="scirp.57570-ref3">3</xref>] , Walraven and Reinhardt [<xref ref-type="bibr" rid="scirp.57570-ref4">4</xref>] and, Loov and Patrnaik [<xref ref-type="bibr" rid="scirp.57570-ref5">5</xref>] who conducted diverse research on the shear frictional behavior. Recently, J&#250;lio and Santos [<xref ref-type="bibr" rid="scirp.57570-ref6">6</xref>] [<xref ref-type="bibr" rid="scirp.57570-ref7">7</xref>] established an acknowledged theory explaining the transfer mechanism of the shear stress occurring at the interface between concrete layers. These authors explained that the shear resistance at the concrete-to-concrete interface is developed through the combination of the adhesive bond caused by the separated placing of the layers, the dowel action of the reinforcing steel, and the friction occurring after the initiation of cracks at the interface [<xref ref-type="bibr" rid="scirp.57570-ref1">1</xref>] . The design specification of Eurocode [<xref ref-type="bibr" rid="scirp.57570-ref8">8</xref>] refers to this theory.</p><p>This study proposes the hybrid girder shown in <xref ref-type="fig" rid="fig1">Figure 1</xref> composing a casing made of 80 MPa-ultra high performance concrete (UHPC) with the upper flange made of 30 MPa-concrete in order to reduce the depth of the steel composite girder.</p><p>The design formula for the shear resistance suggested in Eurocode is applied to determine the amount of shear reinforcement for the composition between the casing and the slab. However, this formula does not consider the strength difference between the concrete layers. Therefore, its applicability is verified by comparing the shear resistance provided by the formula and that obtained through finite element analysis performed considering the interface between concretes of different strengths. Moreover, the amount of steel reinforcement for shear composition is determined using the design formula of Eurocode and adopted to fabricate the girder specimens of which behaviors are compared with respect to the surface roughness of the interface.</p></sec><sec id="s2"><title>2. Verification of Applicability of Eurocode Design Formula by Finite Element Analysis</title><sec id="s2_1"><title>2.1. Eurocode Design Formula for Shear Resistance</title><p>The design formula for the shear resistance at the interface of concretes placed at different times suggested by Eurocode [<xref ref-type="bibr" rid="scirp.57570-ref8">8</xref>] is expressed in Equation (1) using 3 resistance terms.</p><disp-formula id="scirp.57570-formula111"><label>(1)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-8102406x6.png"  xlink:type="simple"/></disp-formula><p>where cf<sub>ctd</sub> = adhesion resistance between materials at interface that is determined with respect to the design tensile strength of concrete (f<sub>ctd</sub>); μσ<sub>n</sub> = shear friction resistance caused by the normal stress (σ<sub>n</sub>) due to external load and that is determined with respect to the surface roughness (μ); and, ρf<sub>syd</sub> (μsinα + cosα) = shear resistance by shear reinforcement that is determined with respect to the reinforcement ratio (ρ), the yield strength of reinforcement (f<sub>syd</sub>), and the surface roughness (μ). Here, the values of the factors c and μ related to the interfacial roughness are given in <xref ref-type="table" rid="table1">Table 1</xref>.</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Concept of hybrid girder bridge with steel girder and UHPC casing</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102406x7.png"/></fig><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Factors related to interfacial roughness [<xref ref-type="bibr" rid="scirp.57570-ref8">8</xref>] </title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Surface condition</th><th align="center" valign="middle" >c</th><th align="center" valign="middle" >μ</th><th align="center" valign="middle" >Remarks</th></tr></thead><tr><td align="center" valign="middle" >Very smooth</td><td align="center" valign="middle" >0.25</td><td align="center" valign="middle" >0.5</td><td align="center" valign="middle" >a surface cast against steel, plastic or specially prepared wooden moulds</td></tr><tr><td align="center" valign="middle" >Smooth</td><td align="center" valign="middle" >0.35</td><td align="center" valign="middle" >0.6</td><td align="center" valign="middle" >a free surface left without further treatment after vibration</td></tr><tr><td align="center" valign="middle" >Rough</td><td align="center" valign="middle" >0.45</td><td align="center" valign="middle" >0.7</td><td align="center" valign="middle" >a surface with at least 3 mm roughness at about 40 mm spacing, achieved by raking, exposing of aggregate</td></tr><tr><td align="center" valign="middle" >Indented</td><td align="center" valign="middle" >0.50</td><td align="center" valign="middle" >0.9</td><td align="center" valign="middle" >a surface with indentations complying with <xref ref-type="fig" rid="fig2">Figure 2</xref></td></tr></tbody></table></table-wrap><p>Equation (1) calculates the shear strength at the interface between members of same strength but placed at different times. It is thus necessary to verify its applicability to the case of members with different strengths. Therefore, the results provided by the design formula and finite element analysis are compared.</p></sec><sec id="s2_2"><title>2.2. Evaluation of Interface Shear Resistance Formula by Finite Element Analysis</title><p><xref ref-type="fig" rid="fig2">Figure 2</xref> presents the model describing the surface roughness by means of indented construction joint. <xref ref-type="fig" rid="fig3">Figure 3</xref> illustrates the finite element model simulating the surface condition at the interface between concrete layers.</p><p>Two heights (d) of 6 mm and 10 mm are chosen for the indent, and analysis is also performed for the smooth surface without irregularities (d = 0 mm). Two models are considered: model SC80-NC30 in which the strength of the lower concrete layer is 80 MPa and that of the upper concrete layer is 30 MPa, and model NC30-NC30 applying the same strength of 30 MPa for both upper and lower concrete layers. The vertical load is applied in the form of an uniformly distributed load of 2.5 kN/m. The analysis is conducted through displacement control in which the upper layer moves horizontally and the lower layer is fixed.</p><p>Equation (2) expresses the stress-strain relation of concrete adopted in the analysis and is the one proposed by fib Model Code [<xref ref-type="bibr" rid="scirp.57570-ref9">9</xref>] . The characteristics values arranged in <xref ref-type="table" rid="table2">Table 2</xref> are applied in Equation (2) to assume the curves plotted in <xref ref-type="fig" rid="fig4">Figure 4</xref>.</p><disp-formula id="scirp.57570-formula112"><label>(2)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-8102406x8.png"  xlink:type="simple"/></disp-formula><p>where <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102406x9.png" xlink:type="simple"/></inline-formula> with ε<sub>cl</sub> = strain at maximum compressive stress; and, k = plasticity number = <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102406x10.png" xlink:type="simple"/></inline-formula> with E<sub>cl</sub> = secant modulus from the origin to the peak compressive stress.</p><p><xref ref-type="fig" rid="fig5">Figure 5</xref> compares the shear resistance obtained by the analysis and the design formula in Equation (1). In <xref ref-type="fig" rid="fig5">Figure 5</xref>(a) comparing the results for smooth surface interface, the analytic result for model NC30-NC30 is seen to be approximately 1.3 times larger than that given by the design formula and, to be about 1.4 times larger for model SC80-NC30. Here, the design value for model SC80-NC30 was calculated assuming concrete strength of 80 MPa for both layers. For the indented surface in <xref ref-type="fig" rid="fig5">Figure 5</xref>(b), the variation in the shear resistance obtained analytically remains below 5% according to the indent depth d. If the depth is larger than 5 mm as shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>, the shear strength obtained by means of the shape of the indent converges to a definite level. With regard to the model with indented surface, the analytical results are seen to be approximately 1.3 times larger than those calculated by the design formula.</p><p>In view of these observations, in case of concrete layers with different strengths, a conservative design value with safety factor of about 1.6 is computed when the shear resistance is calculated by adopting the physical properties of the material with lower strength in the design formula for shear resistance.</p></sec></sec><sec id="s3"><title>3. Loading Test of Girder for Shear Resistance Evaluation with Respect to Interface Condition</title><p>Loading test is performed on girder specimens fabricated considering the inter-layer surface condition as variable in order to evaluate the ultimate load and behavior of the composite section with respect to the design method applied for the shear resistance at the interface between concrete layers. As shown in <xref ref-type="fig" rid="fig6">Figure 6</xref>, the compressive strength of the concrete casing is 80 MPa and that of the concrete slab is 30 MPa. The composition of the steel girder and concrete casing is realized by means of headed studs, and the composition of the concrete</p><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Indented construction joint [<xref ref-type="bibr" rid="scirp.57570-ref8">8</xref>] </title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102406x11.png"/></fig><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> Analysis model for evaluation of shear resistance between concrete layers with different strengths</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102406x12.png"/></fig><fig-group id="fig4"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> Compressive stress-strain curves of concrete. (a) NC30; (b) CS80.</title></caption><fig id ="fig4_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102406x13.png"/></fig><fig id ="fig4_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102406x14.png"/></fig></fig-group><fig-group id="fig5"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> Comparison of shear strength according to concrete-to-concrete interface condition. (a) Smooth surface; (b) Indented surface.</title></caption><fig id ="fig5_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102406x15.png"/></fig><fig id ="fig5_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102406x16.png"/></fig></fig-group><fig id="fig6"  position="float"><label><xref ref-type="fig" rid="fig6">Figure 6</xref></label><caption><title> Cross-section of girder specimen</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102406x17.png"/></fig><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Characteristic values for normal weight concrete [<xref ref-type="bibr" rid="scirp.57570-ref9">9</xref>] </title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Concrete grade</th><th align="center" valign="middle" >C30</th><th align="center" valign="middle" >C80</th></tr></thead><tr><td align="center" valign="middle" >E<sub>ci</sub> (GPa)</td><td align="center" valign="middle" >33.6</td><td align="center" valign="middle" >44.4</td></tr><tr><td align="center" valign="middle" >E<sub>cl</sub> (secant modulus, GPa)</td><td align="center" valign="middle" >16.5</td><td align="center" valign="middle" >31.4</td></tr><tr><td align="center" valign="middle" >ε<sub>cl</sub> (‰)</td><td align="center" valign="middle" >−2.3</td><td align="center" valign="middle" >−2.8</td></tr><tr><td align="center" valign="middle" >ε<sub>c,</sub><sub>lim</sub> (‰)</td><td align="center" valign="middle" >−3.5</td><td align="center" valign="middle" >−3.1</td></tr><tr><td align="center" valign="middle" >k (plasticity number)</td><td align="center" valign="middle" >2.04</td><td align="center" valign="middle" >1.41</td></tr></tbody></table></table-wrap><p>casing and slab is designed using shear reinforcement. The length of the girder is 8 m and loading is applied at the center of the girder.</p><p>Three types of girder specimens are considered according to the design condition between the concrete casing and slab. <xref ref-type="table" rid="table3">Table 3</xref> arranges the interface design results per type of specimen. Here, SC1 designates the specimens without surface treatment and for which the arrangement of shear reinforcement has been designed, SC2 stands for the specimens in which the spacing of shear reinforcement is enlarged considering the shear resistance brought by the interlocking effect of the indents with depth of 6 mm, width of 40 mm, and spacing of 40 mm. SC3 indicates the specimens with surface treatment corresponding to the rough condition in <xref ref-type="table" rid="table1">Table 1</xref> and in which spacing of shear reinforcement is enlarged considering the interlocking effect. The ultimate load by plastic design is 2273 kN for all the specimens.</p><p><xref ref-type="fig" rid="fig7">Figure 7</xref> plots the load-displacement curves per type of specimen obtained by loading test, and <xref ref-type="table" rid="table4">Table 4</xref> lists the measured peak load. In case of SC2 specimen, after the tensile stress in bottom flange of steel girder reached to the yield stress, the specimen abruptly failed by the shear failure in the layer interface. SC3 specimen also failed by the shear failure in the layer interface while it didn’t show the abrupt failure.</p><p>For the failure mode, SC1 failed through compression of the slab of its deck, and SC2 and SC3 underwent</p><fig-group id="fig7"><label><xref ref-type="fig" rid="fig7">Figure 7</xref></label><caption><title> Load-displacement curves. (a) SC1; (b) SC2; (c) SC3.</title></caption><fig id ="fig7_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102406x18.png"/></fig><fig id ="fig7_2"><label> (c)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102406x19.png"/></fig><fig id ="fig7_3"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102406x20.png"/></fig></fig-group><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Design variables according to surface condition per type of specimen</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Specimen</th><th align="center" valign="middle" >Headed stud spacing (mm)<sup>a</sup></th><th align="center" valign="middle" >Shear rebar spacing (mm)<sup>b</sup></th><th align="center" valign="middle"  colspan="2"  >Roughness condition at concrete interface</th></tr></thead><tr><td align="center" valign="middle" >SC1</td><td align="center" valign="middle"  rowspan="3"  >205</td><td align="center" valign="middle" >115</td><td align="center" valign="middle" >Smooth</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102406x21.png" xlink:type="simple"/></inline-formula></td></tr><tr><td align="center" valign="middle" >SC2</td><td align="center" valign="middle" >600</td><td align="center" valign="middle" >Indented (d = 6 mm, spacing 40 mm)</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102406x22.png" xlink:type="simple"/></inline-formula></td></tr><tr><td align="center" valign="middle" >SC3</td><td align="center" valign="middle" >300</td><td align="center" valign="middle" >Rough</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102406x23.png" xlink:type="simple"/></inline-formula></td></tr></tbody></table></table-wrap><p><sup>a</sup>Composition of steel girder and concrete casing; <sup>b</sup>Composition of concrete casing and slab.</p><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> Comparison of loading test results</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Specimen type</th><th align="center" valign="middle" >Interface conditon</th><th align="center" valign="middle" >Spacing of shear reinforcement (mm)</th><th align="center" valign="middle" >Surface roughness, μ</th><th align="center" valign="middle" >Interface failure design load, F<sub>D</sub> (kN)</th><th align="center" valign="middle" >Peak load, F<sub>t</sub> (kN)</th><th align="center" valign="middle" >F<sub>t</sub>/F<sub>D</sub></th><th align="center" valign="middle" >Failure mode</th></tr></thead><tr><td align="center" valign="middle" >SC1</td><td align="center" valign="middle" >Smooth</td><td align="center" valign="middle" >115</td><td align="center" valign="middle" >0.35</td><td align="center" valign="middle" >2273</td><td align="center" valign="middle" >2412</td><td align="center" valign="middle" >1.06</td><td align="center" valign="middle" >Flexural failure</td></tr><tr><td align="center" valign="middle" >SC2</td><td align="center" valign="middle" >Indented</td><td align="center" valign="middle" >600</td><td align="center" valign="middle" >0.5</td><td align="center" valign="middle" >2273</td><td align="center" valign="middle" >2138</td><td align="center" valign="middle" >0.94</td><td align="center" valign="middle" >Shear failure</td></tr><tr><td align="center" valign="middle" >SC3</td><td align="center" valign="middle" >Rough</td><td align="center" valign="middle" >300</td><td align="center" valign="middle" >0.45</td><td align="center" valign="middle" >2273</td><td align="center" valign="middle" >2152</td><td align="center" valign="middle" >0.92</td><td align="center" valign="middle" >Shear failure</td></tr></tbody></table></table-wrap><p>shear failure of the interface between the concrete casing and slab. Particularly, specimen SC2 with surface treatment by means of 6 mm-deep indents experienced sudden failure of the interfacial indents during the loading process.</p><p>For the peak load, only specimen SC1 showed a peak load increased by 6% compared to the design load whereas specimens SC2 and SC3 failed at loads lower by 6% to 8% than the design load due to shear failure at the inter-concrete interface.</p><p><xref ref-type="fig" rid="fig8">Figure 8</xref> plots the strain distribution at yield load and peak load inside the central cross-section. For SC1, the strain distribution is linear until the peak load, which indicates that the specimen develops perfectly composite behavior. Whereas, for SC2 and SC3, the strain distribution shows the discontinuity and snapping point at the location of concrete casing and slab (at height of 275 mm), and it means the shear bond failure in the layer interface.</p><fig-group id="fig8"><label><xref ref-type="fig" rid="fig8">Figure 8</xref></label><caption><title> Strain distribution in central cross-section of girder. (a) SC1; (b) SC2; (c) SC3.</title></caption><fig id ="fig8_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102406x24.png"/></fig><fig id ="fig8_2"><label> (c)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102406x25.png"/></fig><fig id ="fig8_3"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102406x26.png"/></fig></fig-group></sec><sec id="s4"><title>4. Conclusions</title><p>This study investigated the applicability of the design formula for shear resistance in concrete-to-concrete interface suggested in Eurocode to the case composing concrete layers with two different compressive strengths of 80 MPa and 30 MPa. To that goal, finite element analysis was performed to examine the effect of the surface condition of concrete on the shear strength. The results showed that, in case of concrete layers with different strengths, a conservative design value with safety factor of about 1.6 compared to the analytical value can be obtained when the shear resistance is calculated by adopting the lower strength in the design formula for shear resistance.</p><p>Based on such observation, the interfacial behavior and ultimate load were evaluated on hybrid girder specimens composing members of different strengths and fabricated considering the interface condition as variable. Referring to the specimen with smooth interface, the shear reinforcement for the composition of the specimens was designed so as to reduce the amount of reinforcement through the enlargement of the reinforcement spacing considering the shear resistance provided by the interlocking effect of the rough surface condition and indent condition at the interface. However, the loading test revealed that the actual ultimate load occurred at values lower by approximately 2% to 8% than the interface failure design load and that perfectly composite behavior could not be achieved. This could be explained by the fact that the design formula for shear resistance suggested in the design code is effective under the action of pure shear but fails to provide appropriate value for the interfacial shear resistance under the combined action of flexure and shear. It appears that conservative design shall be conducted by applying partial safety factor.</p></sec><sec id="s5"><title>Acknowledgements</title><p>This study was supported financially through the project “Development of SUPER Concrete with compressive strength of 80 - 180 MPa and its application (2nd year)”. The authors express their gratitude for the support.</p></sec><sec id="s6"><title>Cite this paper</title><p>Jae YoonKang,Jong SupPark,Woo TaiJung,Moon SeoungKeum, (2015) Connection between Concrete Layers with Different Strengths. Engineering,07,365-372. doi: 10.4236/eng.2015.77032</p></sec><sec id="s7"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.57570-ref1"><label>1</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Hanson</surname><given-names> N.W. </given-names></name>,<etal>et al</etal>. (<year>1960</year>)<article-title>Precast-Prestressed Concrete Bridges 2. Horizontal Shear Connections</article-title><source> Journal of the PCA Research and Development Laboratories</source><volume> 2</volume>,<fpage> 38</fpage>-<lpage>58</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.57570-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Birkeland, H.W. and Birkeland, P.W. (1996) Connections in Precast Concrete Construction. Journal of the ACI, 63, 345-368.</mixed-citation></ref><ref id="scirp.57570-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Mattock, A.H. and Hawkins, N.M. (1972) Shear Transfer in Reinforced Concrete—Recent Research. PCI Journal, 17, 55-75. http://dx.doi.org/10.15554/pcij.03011972.55.75</mixed-citation></ref><ref id="scirp.57570-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Walraven, J.C. and Reinhardt, H.W. (1981) Theory and Experiments on the Mechanical Behaviour of Cracks in Plain and Reinforced Concrete Subjected to Shear Loading. Heron, 26.</mixed-citation></ref><ref id="scirp.57570-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Loov, R.E. and Patnaik, A.K. (1994) Horizontal Shear Strength of Composite Concrete Beams with Rough Interface. PCI Journal, 39, 48-69. http://dx.doi.org/10.15554/pcij.01011994.48.69</mixed-citation></ref><ref id="scirp.57570-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">J&amp;uacute;lio, E., Branco, F. and Silva, V. (2004) Concrete-to-Concrete Bond Strength. Influence of the Roughness of the Substrate Surface. Construction and Building Materials, 18, 675-681. http://dx.doi.org/10.1016/j.conbuildmat.2004.04.023</mixed-citation></ref><ref id="scirp.57570-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">J&amp;uacute;lio, E. and Santos, P. (2010) Comparison of Methods for Texture Assessment of Concrete Surfaces. ACI Materials Journal, 107, 433-440.</mixed-citation></ref><ref id="scirp.57570-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">European Committee for Standardization (2002) EN 1992-1-1 Eurocode 2: Design of Concrete Structures—Part I: General Rules and Rules for Buildings.</mixed-citation></ref><ref id="scirp.57570-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">CEB-FIP (2010) Fib Model Code for Concrete Structures.</mixed-citation></ref></ref-list></back></article>