<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">ENG</journal-id><journal-title-group><journal-title>Engineering</journal-title></journal-title-group><issn pub-type="epub">1947-3931</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/eng.2015.73009</article-id><article-id pub-id-type="publisher-id">ENG-54784</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Torsional Behavior Design of UHPC Box Beams Based on Thin-Walled Tube Theory
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>mjong</surname><given-names>Kwahk</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Changbin</surname><given-names>Joh</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jung</surname><given-names>Woo Lee</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Korea Institute of Civil Engineering and Building Technology, Goyang, South Korea</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>kwakim@kict.re.kr(MK)</email>;<email>cjoh@kict.re.kr(CJ)</email>;<email>duckhawk@kict.re.kr(JWL)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>18</day><month>03</month><year>2015</year></pub-date><volume>07</volume><issue>03</issue><fpage>101</fpage><lpage>114</lpage><history><date date-type="received"><day>28</day>	<month>February</month>	<year>2015</year></date><date date-type="rev-recd"><day>accepted</day>	<month>15</month>	<year>March</year>	</date><date date-type="accepted"><day>18</day>	<month>March</month>	<year>2015</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  This study proposed a prediction formula for the torsional strength enabling to reflect the tensile strength of ultra high performance concrete (UHPC) beams based upon the thin-walled tube theory. The remarkable ductile behavior of UHPC can also be attributed to the steel fiber reinforcement. This feature must be considered to provide rational explanation of the torsional behavior of UHPC structures. In this study, the proposed torsional design adopts a modified thin-walled tube theory so as to consider the tensile behavior of UHPC. And torsion test was conducted on thin-walled UHPC box beams to validate the proposed formula through comparison of the predicted torsional strength with the experimental results. The comparison of the predicted values of the cracking torque and torsional moment resistance with those observed in the torsional test of UHPC verified the validity of the design method. The contribution of the steel fibers to the torsional strength and cracking load was larger than that of the stirrups, but the stirrups appeared to contribute additionally to the torsional ductility. Accordingly, it is recommended that design should exploit effectively the contribution of the steel fiber rather than arrange a larger number of stirrups in UHPC structures subjected to torsion.
 
</p></abstract><kwd-group><kwd>Torsion Behavior</kwd><kwd> Ultra High Performance Concrete (UHPC)</kwd><kwd> Thin-Walled Tube</kwd><kwd> Torsional  Strength</kwd><kwd> Diagonal Crack</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Ultra high performance concrete (UHPC) is an advanced cementitious composite exhibiting low permeability in which the matrix with high density and strength is reinforced by steel fibers [<xref ref-type="bibr" rid="scirp.54784-ref1">1</xref>] -[<xref ref-type="bibr" rid="scirp.54784-ref4">4</xref>] . This composite develops significantly higher tensile strength than ordinary concrete [<xref ref-type="bibr" rid="scirp.54784-ref5">5</xref>] and continues to show outstanding behavior after cracking [<xref ref-type="bibr" rid="scirp.54784-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.54784-ref6">6</xref>] . However, despite of its remarkable strength and performances compared with normal strength concrete (NSC), this material is still costly. Accordingly, the structures applying UHPC present often more complicated shapes and reduced cross sectional dimensions than when applying NSC. This situation stresses the importance of the torsional design of UHPC structures.</p><p>Studies reported that the design of torsional reinforcement focused essentially on stirrups by disregarding the tensile behavior of concrete in the case of NSC structures [<xref ref-type="bibr" rid="scirp.54784-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.54784-ref8">8</xref>] . Other studies were also dedicated to the tor- sional behavior of prestressed NSC structures [<xref ref-type="bibr" rid="scirp.54784-ref9">9</xref>] . Several studies also considered the torsional behavior of structures made of high strength concrete (HSC) without steel fiber reinforcement [<xref ref-type="bibr" rid="scirp.54784-ref10">10</xref>] -[<xref ref-type="bibr" rid="scirp.54784-ref15">15</xref>] . However, HSC shows poor torsional ductility, and offers very narrow reinforcement ratio enabling to preserve the ductility [<xref ref-type="bibr" rid="scirp.54784-ref15">15</xref>] ; and the torsional cracks are more brittle than in NSC [<xref ref-type="bibr" rid="scirp.54784-ref13">13</xref>] .</p><p>Many researchers led investigation on the improvement of the tensile strength and ductility of NSC by steel fiber reinforcement and found out that the adoption of steel fiber achieved improved flexural ductility and ten- sile strength [<xref ref-type="bibr" rid="scirp.54784-ref16">16</xref>] -[<xref ref-type="bibr" rid="scirp.54784-ref18">18</xref>] as well as significant amelioration of the shear strength [<xref ref-type="bibr" rid="scirp.54784-ref19">19</xref>] [<xref ref-type="bibr" rid="scirp.54784-ref20">20</xref>] . Further studies also re- ported the effectiveness of steel fiber in improving the torsional behavior [<xref ref-type="bibr" rid="scirp.54784-ref21">21</xref>] -[<xref ref-type="bibr" rid="scirp.54784-ref26">26</xref>] .</p><p>The remarkable ductile behavior of UHPC can also be attributed to the steel fiber reinforcement. This feature must be considered to provide rational explanation of the torsional behavior of UHPC structures. The current design specification of ACI 318-11 describes the torsional design of structures based upon the thin-walled tube theory [<xref ref-type="bibr" rid="scirp.54784-ref27">27</xref>] , but its straightforward application to UHPC cannot consider properly the effect resulting from the improvement of the ductile behavior of UHPC identified experimentally. Accordingly, the torsional design me- thod of the UHPC beam shall be based on a modified theory enabling to account for the tensile behavior of UHPC rather than the traditional theory.</p><p>In this study, the proposed torsional design adopts a modified thin-walled tube theory so as to consider the tensile behavior of UHPC and the validity of the method is verified through comparison with experimental data. Most of the recent studies on UHPC focused only on the difference in the constitutive materials as compared with normal concrete. Despite of the insufficiency of experimental research utilizable for the analysis of the tor- sional behavior of UHPC beams, Yang, Joh, Lee and Kim conducted the experimental analysis of the pure tor- sional behavior of UHPC beams with rectangular cross-section [<xref ref-type="bibr" rid="scirp.54784-ref28">28</xref>] .</p><p>Accordingly, this experimental study intends to propose a torsional design method based on the thin-walled tube theory and considering the tensile strength of UHPC. UHPC beams with thin-walled box cross-section were fabricated and subjected to pure torsion test for comparison with the theoretical data and to verify the validity of the proposed design method.</p></sec><sec id="s2"><title>2. Torsional Design Based on Thin-Walled Theory</title><p>In order to obtain the ultimate strength of the UHPC beam considering the tensile behavior of UHPC, the beam undergoing cracking due to the torsional moment T is idealized as a thin-walled tube (<xref ref-type="fig" rid="fig1">Figure 1</xref>).</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Thin-wall tube model UHPC beam</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x6.png"/></fig><p>The total shear forces <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x7.png" xlink:type="simple"/></inline-formula> and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x8.png" xlink:type="simple"/></inline-formula> at the top and bottom flanges of the box beam caused by the torsional moment <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x9.png" xlink:type="simple"/></inline-formula> shown in <xref ref-type="fig" rid="fig1">Figure 1</xref> can be expressed as follows,</p><disp-formula id="scirp.54784-formula59"><label>(1)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-8102326x10.png"  xlink:type="simple"/></disp-formula><p>and, the total shear forces <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x11.png" xlink:type="simple"/></inline-formula> and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x12.png" xlink:type="simple"/></inline-formula> in both webs can be expressed as follows in a similar manner,</p><disp-formula id="scirp.54784-formula60"><label>(2)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-8102326x13.png"  xlink:type="simple"/></disp-formula><p>where <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x14.png" xlink:type="simple"/></inline-formula> area delimited by the centerline of the shear flow; <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x15.png" xlink:type="simple"/></inline-formula>width of<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x16.png" xlink:type="simple"/></inline-formula>; and, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x17.png" xlink:type="simple"/></inline-formula>height of<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x18.png" xlink:type="simple"/></inline-formula>.</p><p>The number of stirrups including the inclined crack surface at the leftward face of the UHPC beam (<xref ref-type="fig" rid="fig2">Figure 2</xref>) in which torsion-induced cracks occurred is obtained by Equation (3).</p><disp-formula id="scirp.54784-formula61"><label>(3)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-8102326x19.png"  xlink:type="simple"/></disp-formula><p>where <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x20.png" xlink:type="simple"/></inline-formula> number of stirrups including the inclined crack surface; <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x21.png" xlink:type="simple"/></inline-formula>inclination angle of compression strut; and, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x21.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x22.png" xlink:type="simple"/></inline-formula>spacing of closed stirrup.</p><p><xref ref-type="fig" rid="fig2">Figure 2</xref> shows vertical forces resulting from tensile strength of UHPC <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x23.png" xlink:type="simple"/></inline-formula> acting on a crack surface with inclination angle <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x23.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x24.png" xlink:type="simple"/></inline-formula> and tensile strength of stirrups. <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x23.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x24.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x25.png" xlink:type="simple"/></inline-formula>stands for the cross-sectional area of one closed stirrup resisting to torsion within spacing s.</p><p>Accordingly, assuming that all the stirrups yield at ultimatetorsion limit state and that UHPC reaches its ten- sile strength<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x26.png" xlink:type="simple"/></inline-formula>, the contribution <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x26.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x27.png" xlink:type="simple"/></inline-formula> to the shear force <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x26.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x27.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x28.png" xlink:type="simple"/></inline-formula> of the stirrup can be calculated as follows,</p><disp-formula id="scirp.54784-formula62"><label>(4)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-8102326x29.png"  xlink:type="simple"/></disp-formula><p>where <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x30.png" xlink:type="simple"/></inline-formula> yield strength of transverse reinforcement.</p><p>Moreover, Equation (5) expresses the tensile force of UHPC acting vertically to the inclined crack surface of <xref ref-type="fig" rid="fig2">Figure 2</xref>.</p><disp-formula id="scirp.54784-formula63"><label>(5)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-8102326x31.png"  xlink:type="simple"/></disp-formula><p>where <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x32.png" xlink:type="simple"/></inline-formula> tensile strength of UHPC; and, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x32.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x33.png" xlink:type="simple"/></inline-formula>thickness of thin wall when assuming the UHPC beam as equivalent thin-walled tube for torsional strength.</p><p>Therefore, the vertical component in Equation (5) that is the contribution <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x34.png" xlink:type="simple"/></inline-formula> to the shear force <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x34.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x35.png" xlink:type="simple"/></inline-formula> of UHPC can be expressed as follows</p><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Vertical forces in leftward face of UHPC thin-walled tube models</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x36.png"/></fig><disp-formula id="scirp.54784-formula64"><label>(6)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-8102326x37.png"  xlink:type="simple"/></disp-formula><p>Consequently, the total shear force <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x38.png" xlink:type="simple"/></inline-formula> acting on the leftward face of the beam can be obtained by Equation (7).</p><disp-formula id="scirp.54784-formula65"><label>(7)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-8102326x39.png"  xlink:type="simple"/></disp-formula><p>In addition, the corresponding torsional moment <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x40.png" xlink:type="simple"/></inline-formula> is the ultimate torsional moment <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x40.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x41.png" xlink:type="simple"/></inline-formula> that can be sus- tained by the section, and can be obtained as follows based on Equations (7) and (2).</p><disp-formula id="scirp.54784-formula66"><label>(8)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-8102326x42.png"  xlink:type="simple"/></disp-formula><p>By distinguishing the contributions of the steel reinforcement and UHPC, Equation (8) becomes</p><disp-formula id="scirp.54784-formula67"><label>(9)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-8102326x43.png"  xlink:type="simple"/></disp-formula><p>The cracking torque <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x44.png" xlink:type="simple"/></inline-formula> can also be obtained consistently by applying the thin-walled beam theory. In other words, the shear stress <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x44.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x45.png" xlink:type="simple"/></inline-formula> at which inclined cracks initiate at one side of the UHPC beam under the action of the cracking torque <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x44.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x45.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x46.png" xlink:type="simple"/></inline-formula> can be calculated as follows.</p><disp-formula id="scirp.54784-formula68"><label>(10)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-8102326x47.png"  xlink:type="simple"/></disp-formula><p>where <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x48.png" xlink:type="simple"/></inline-formula> thickness of UHPC beam assumed as equivalent thin-walled tube.</p><p>Moreover, if the member transverse compressive stress <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x49.png" xlink:type="simple"/></inline-formula> induced by prestress applies, the principal stress <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x49.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x50.png" xlink:type="simple"/></inline-formula> can be obtained using the Mohr’s circle shown in <xref ref-type="fig" rid="fig3">Figure 3</xref> [<xref ref-type="bibr" rid="scirp.54784-ref29">29</xref>] . Here, the compressive stress <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x49.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x50.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x51.png" xlink:type="simple"/></inline-formula> must be positive considering the sign convention.</p><disp-formula id="scirp.54784-formula69"><label>(11)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-8102326x52.png"  xlink:type="simple"/></disp-formula><p>If this principal stress <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x53.png" xlink:type="simple"/></inline-formula> becomes equal to the crack strength <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x53.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x54.png" xlink:type="simple"/></inline-formula> of UHPC, the shear stress <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x53.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x54.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x55.png" xlink:type="simple"/></inline-formula> developed in one side of the UHPC beam becomes <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x53.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x54.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x55.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x56.png" xlink:type="simple"/></inline-formula> inducing inclined cracks. Therefore, Equation (11) can be rewrit- ten as follows for<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x53.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x54.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x55.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x56.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x57.png" xlink:type="simple"/></inline-formula>.</p><disp-formula id="scirp.54784-formula70"><label>(12)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-8102326x58.png"  xlink:type="simple"/></disp-formula><p>Hence, the cracking torque <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x59.png" xlink:type="simple"/></inline-formula> can be obtained as follows from Equations (10) and (12).</p><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> Principal stress of prestressed torsional member [<xref ref-type="bibr" rid="scirp.54784-ref29">29</xref>] </title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x60.png"/></fig><disp-formula id="scirp.54784-formula71"><label>(13)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-8102326x61.png"  xlink:type="simple"/></disp-formula><p>In addition, the inclination angle <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x62.png" xlink:type="simple"/></inline-formula> of the inclined crack can be expressed as follow using the Mohr’s circle.</p><disp-formula id="scirp.54784-formula72"><label>(14)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-8102326x63.png"  xlink:type="simple"/></disp-formula></sec><sec id="s3"><title>3. Test Schedule</title><sec id="s3_1"><title>3.1. Material Characteristics</title><p>Ordinary Portland cement is used in the mix of steel fiber reinforced UHPC, and reactive powder and silica fume are also introduced. A water-to-binder of 0.2% is applied. Sand with grain size of 0.5 mm is used as fine aggregate, and coarse aggregate is not used. The filler is made of materials with average grain size of 10 μm, SiO<sub>2</sub> content larger than 98% and density of 7500 kg/m<sup>3</sup>. Straight steel fiber is adopted with density of 7500 kg/m<sup>3</sup>, yield strength of 2500 MPa and diameter of 0.2 mm. Two fiber lengths of 16.5 mm and 19.5 mm are used concurrently at volume fractions of 1% and 1.5%.</p><p>Series of 6 specimens for tensile strength test were fabricated at each batch during the manufacture of the beam member using the placed UHPC. Direct tensile test was conducted to evaluate the tensile strength of each specimen. The dogbone type tensile specimens shown in <xref ref-type="fig" rid="fig4">Figure 4</xref> were notched on both side of their center to a depth 12.5 mm. Crack gages were used to measure the crack mouth opening displacement (CMOD) of the notch according to the increase of the tensile load so as to compute the crack initiation strength and tensile strength of each specimen. <xref ref-type="table" rid="table1">Table 1</xref> arranges the average values calculated for the specimens of each batch.</p></sec><sec id="s3_2"><title>3.2. Test Members</title><p>The test members were fabricated with rectangular box cross-section and dimensions of 350 mm &#180; 350 mm &#180; 3000 mm. For the tested part of the member, the central part (section B-B) was designed to have a wall thick- ness of 50 mm to induce torsional failure. To that goal, both ends of the member (section A-A) were designed with wall thickness of 120 mm, dense arrangement of D10 stirrups at spacing of 50 mm along a length of 650 mm, and the installation of 3 longitudinal reinforcements in each side of the rectangular cross-section. Moreover, apart from the ends of the member, D10 stirrups were disposed in section B-B along the member at spacing of 170 mm or 340 mm.</p><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> Dogbone UHPC specimen for direct tensile test</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x64.png"/></fig><p>For the members with prestress, nineteen 7-wire tendons with nominal diameter of 15.2 mm (SWPC7, yield strength of 1860 MPa) were installed at the center of the empty box of the member.</p><p>A total of 14 test members corresponding to 2 specimens for each of 7 types were fabricated considering the test variables that are the volume fraction of steel fiber (1.0%, 1.5%), the amount of stirrups and reinforcing steel, and the introduction of prestress. <xref ref-type="table" rid="table2">Table 2</xref> arranges the characteristics of the specimens. <xref ref-type="fig" rid="fig5">Figure 5</xref> and <xref ref-type="fig" rid="fig6">Figure 6</xref> illustrate the cross-sections and side view of the UHPC box beam members. As shown <xref ref-type="fig" rid="fig5">Figure 5</xref> and <xref ref-type="fig" rid="fig6">Figure 6</xref>, section A-A in both side of box beams was heavily reinforced with large number of stirrups and thick UHPC wall so as to protect occurrence of diagonal cracks in those region.</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Tensile strength of UHPC torsion specimens (MPa)</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Specimen designation</th><th align="center" valign="middle" >Crack initiation strength</th><th align="center" valign="middle" >Tensile strength</th></tr></thead><tr><td align="center" valign="middle" >SH-P0-F1.5-L1-S1(D13)</td><td align="center" valign="middle" >8.23</td><td align="center" valign="middle" >11.48</td></tr><tr><td align="center" valign="middle" >SH-P2-F1.5-L1-S1</td><td align="center" valign="middle" >7.81</td><td align="center" valign="middle" >11.30</td></tr><tr><td align="center" valign="middle" >SH-P4-F1.5-L1-S1</td><td align="center" valign="middle" >8.25</td><td align="center" valign="middle" >11.44</td></tr><tr><td align="center" valign="middle" >SH-P0-F1-L1-S1</td><td align="center" valign="middle" >6.96</td><td align="center" valign="middle" >8.39</td></tr><tr><td align="center" valign="middle" >SH-P4-F1-L1-S1</td><td align="center" valign="middle" >5.90</td><td align="center" valign="middle" >7.09</td></tr><tr><td align="center" valign="middle" >SH-P0-F1.5-L1-S2</td><td align="center" valign="middle" >7.77</td><td align="center" valign="middle" >11.18</td></tr><tr><td align="center" valign="middle" >SH-P0-F1.5-L1-S1(D10)</td><td align="center" valign="middle" >8.23</td><td align="center" valign="middle" >11.48</td></tr></tbody></table></table-wrap><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Dimensions of UHPC beam specimens for torsion test (mm)</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Specimen designation</th><th align="center" valign="middle"  colspan="2"  >Steel fiber (%)</th><th align="center" valign="middle"  colspan="2"  >Steel reinforcement</th><th align="center" valign="middle"  rowspan="2"  >Stirrup spacing</th></tr></thead><tr><td align="center" valign="middle" >16.5 mm</td><td align="center" valign="middle" >19.2 mm</td><td align="center" valign="middle" >Stirrup</td><td align="center" valign="middle" >Longitudinal</td></tr><tr><td align="center" valign="middle" >SH-P0-F1.5-L1-S1(D13)</td><td align="center" valign="middle" >0.5</td><td align="center" valign="middle" >1</td><td align="center" valign="middle" >D10</td><td align="center" valign="middle" >D13@4</td><td align="center" valign="middle" >5@340</td></tr><tr><td align="center" valign="middle" >SH-P2-F1.5-L1-S1</td><td align="center" valign="middle" >0.5</td><td align="center" valign="middle" >1</td><td align="center" valign="middle" >D10</td><td align="center" valign="middle" >D22@4</td><td align="center" valign="middle" >5@340</td></tr><tr><td align="center" valign="middle" >SH-P4-F1.5-L1-S1</td><td align="center" valign="middle" >0.5</td><td align="center" valign="middle" >1</td><td align="center" valign="middle" >D10</td><td align="center" valign="middle" >D22@4</td><td align="center" valign="middle" >5@340</td></tr><tr><td align="center" valign="middle" >SH-P0-F1-L1-S1</td><td align="center" valign="middle" >0.5</td><td align="center" valign="middle" >0.5</td><td align="center" valign="middle" >D10</td><td align="center" valign="middle" >D13@4</td><td align="center" valign="middle" >5@340</td></tr><tr><td align="center" valign="middle" >SH-P4-F1-L1-S1</td><td align="center" valign="middle" >0.5</td><td align="center" valign="middle" >0.5</td><td align="center" valign="middle" >D10</td><td align="center" valign="middle" >D22@4</td><td align="center" valign="middle" >5@340</td></tr><tr><td align="center" valign="middle" >SH-P0-F1.5-L1-S2</td><td align="center" valign="middle" >0.5</td><td align="center" valign="middle" >1</td><td align="center" valign="middle" >D10</td><td align="center" valign="middle" >D10@4</td><td align="center" valign="middle" >10@170</td></tr><tr><td align="center" valign="middle" >SH-P0-F1.5-L1-S1(D10)</td><td align="center" valign="middle" >0.5</td><td align="center" valign="middle" >1</td><td align="center" valign="middle" >D10</td><td align="center" valign="middle" >D10@4</td><td align="center" valign="middle" >5@340</td></tr></tbody></table></table-wrap><fig id="fig5"  position="float"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> Cross-section of UHPC box beam specimen</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x65.png"/></fig></sec><sec id="s3_3"><title>3.3. Test Method</title><p>The torque was applied as shown in <xref ref-type="fig" rid="fig7">Figure 7</xref> using an actuator with capacity of 1000 kN. The torsional moment lever arm was 0.9 m and the torsional load was applied at the 2.3 m spot of the 3 m long box beam specimens. One support of the member was fixed to restrain rotation while the other support was installed with an arc bear- ing to allow free rotation in the transverse direction.</p><p>For the prestressed member, a hydraulic jack for the introduction of the prestress force in the tendon and a load cell for the measurement of the prestress force were installed in series at the fixed end of the member as shown in <xref ref-type="fig" rid="fig8">Figure 8</xref>(a) and <xref ref-type="fig" rid="fig8">Figure 8</xref>(c). Moreover, at the hinged end, a spherical roller trust bearing with vertical capacity of 600 ton was installed in series between the anchor plate for the tendon and the end of the member as shown in <xref ref-type="fig" rid="fig8">Figure 8</xref>(b). This roller was installed to prevent the risk of damage of the tensioned tendons inside the member box due to twisting or change in the axial load under the rotation of the beam. Different amounts of prestress were applied as 0.0 MPa, 12.5 MPa, 25.0 MPa, and 50.0 MPa according to the test member, and the corresponding behavioral change was observed through the crack inclination and torsional strength.</p><p>A loading beam was installed at the rotating support. The load was applied at the position of the loading lo- cated at a distance of 0.9 m from the centerline of the member, which corresponds to the lever arm. Loading was applied through displacement control at speed of 0.03 mm/s. The rotating end was fabricated considering the ro- tation radius with respect to the centerline of the member.</p><p>The observation of the torsional angle or angle of twist of the beam was done by measuring the deflection at each loading stage using steel frames and LVDTs installed at sections located at 800 mm and 200 mm far from the center of the span as shown in <xref ref-type="fig" rid="fig9">Figure 9</xref>.</p><fig id="fig6"  position="float"><label><xref ref-type="fig" rid="fig6">Figure 6</xref></label><caption><title> Side elevation view of UHPC box beam specimen</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x66.png"/></fig><fig-group id="fig7"><label><xref ref-type="fig" rid="fig7">Figure 7</xref></label><caption><title> Schematic drawing of test configuration and view of test setup.</title></caption><fig id ="fig7_1"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x67.png"/></fig><fig id ="fig7_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x68.png"/></fig></fig-group><fig-group id="fig8"><label><xref ref-type="fig" rid="fig8">Figure 8</xref></label><caption><title> Jacking of tendon for prestressing and installation of bearing.</title></caption><fig id ="fig8_1"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x69.png"/></fig><fig id ="fig8_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x71.png"/></fig><fig id ="fig8_3"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x70.png"/></fig><fig id ="fig8_4"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x72.png"/></fig></fig-group><fig id="fig9"  position="float"><label><xref ref-type="fig" rid="fig9">Figure 9</xref></label><caption><title> Layout of displacement gauges</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x73.png"/></fig></sec></sec><sec id="s4"><title>4. Test Results and Discussion</title><sec id="s4_1"><title>4.1. Crack Characteristics</title><p>The propagation of the cracks was observed at each loading stage until failure, and the relation between the tor- sional moment-angle of twist was measured. <xref ref-type="table" rid="table3">Table 3</xref> arranges the inclination angle of the cracks measured with reference to the centerline of the member at the initiation of crack.</p><p>Initial cracking occurred in the form of inclined cracks with inclination angles ranging between 46.7˚ and 51.3˚ with reference to the centerline of the beam in the specimens without prestress, which gives an average angle of 49.7˚. For the prestressed members, the crack angles diminished gradually with larger longitudinal prestress to range between 14˚ and 15˚ in the case of the peak prestress of 50 MPa as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>0(a).</p><p>After the initiation of the torsional cracks, the cracks exhibited spiral shape along the 4 sides of the members according to the increase of the torsional moment together with the occurrence of numerous torsional cracks. These additional cracks seem to enhance the load bearing capacity of the member owing to the redistribution of stress. Just prior to the peak torsional moment, some specific cracks among the inclined cracks showed increase of their crack width and developed into principal inclined cracks. After the peak load, the torsional moment re- duced with the acceleration of the pullout of the steel fibers and failure occurred as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>0(b) with the sudden widening of the crack width of the principal inclined cracks. This process can be explained by the in- creased resistance to torsional moment provided by the bridging effect of the steel fibers from the initiation of cracks to the ultimate loading stage and, the loss of this resistance after the ultimate load due to the reduction of</p><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Crack inclination of UHPC beam specimens</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Specimen designation</th><th align="center" valign="middle"  colspan="2"  >Crack inclination (degree)</th><th align="center" valign="middle"  rowspan="2"  >Prestress (MPa)</th></tr></thead><tr><td align="center" valign="middle" >Test</td><td align="center" valign="middle" >Theory</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >SH-P0-F1.5-L1-S1(D13)</td><td align="center" valign="middle" >46.7</td><td align="center" valign="middle" >45.0</td><td align="center" valign="middle" >0</td></tr><tr><td align="center" valign="middle" >50.4</td><td align="center" valign="middle" >45.0</td><td align="center" valign="middle" >0</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >SH-P2-F1.5-L1-S1</td><td align="center" valign="middle" >19.8</td><td align="center" valign="middle" >26.4</td><td align="center" valign="middle" >25.0</td></tr><tr><td align="center" valign="middle" >23.4</td><td align="center" valign="middle" >26.4</td><td align="center" valign="middle" >25.0</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >SH-P4-F1.5-L1-S1</td><td align="center" valign="middle" >30.9</td><td align="center" valign="middle" >32.1</td><td align="center" valign="middle" >12.5</td></tr><tr><td align="center" valign="middle" >27.3</td><td align="center" valign="middle" >26.4</td><td align="center" valign="middle" >25.0</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >SH-P0-F1-L1-S1</td><td align="center" valign="middle" >48.5</td><td align="center" valign="middle" >45.0</td><td align="center" valign="middle" >0</td></tr><tr><td align="center" valign="middle" >50.3</td><td align="center" valign="middle" >45.0</td><td align="center" valign="middle" >0</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >SH-P4-F1-L1-S1</td><td align="center" valign="middle" >14.0</td><td align="center" valign="middle" >18.1</td><td align="center" valign="middle" >50.0</td></tr><tr><td align="center" valign="middle" >15.1</td><td align="center" valign="middle" >18.1</td><td align="center" valign="middle" >50.0</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >SH-P0-F1.5-L1-S2</td><td align="center" valign="middle" >51.3</td><td align="center" valign="middle" >45.0</td><td align="center" valign="middle" >0</td></tr><tr><td align="center" valign="middle" >50.8</td><td align="center" valign="middle" >45.0</td><td align="center" valign="middle" >0</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >SH-P0-F1.5-L1-S1(D10)</td><td align="center" valign="middle" >49.2</td><td align="center" valign="middle" >45.0</td><td align="center" valign="middle" >0</td></tr><tr><td align="center" valign="middle" >50.6</td><td align="center" valign="middle" >45.0</td><td align="center" valign="middle" >0</td></tr></tbody></table></table-wrap><fig-group id="fig10"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>0</label><caption><title> Representative cracking patterns of torsional member.</title></caption><fig id ="fig10_1"><label> Crack growth stage (SH-P4-F1-L1-S1)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x74.png"/></fig><fig id ="fig10_2"><label> (50 MPa prestress)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x75.png"/></fig></fig-group><p>the bridging effect of the steel fibers at the principal inclined cracks. Similar crack propagation and failure pattern were observed in previous experimental studies on rectangular plain UHPC beams [<xref ref-type="bibr" rid="scirp.54784-ref28">28</xref>] .</p></sec><sec id="s4_2"><title>4.2. Torsional Strength Characteristics according to the Change of Reinforcement</title><p><xref ref-type="fig" rid="fig1">Figure 1</xref>1 plots the relation between the torsional moment and the angle of twist measured in the non-prestressed members. At early loading, the relation is nearly linear. With the increase of the volume fraction of steel fiber from 1.0% to 1.5%, the maximum torsional moment undergoes clear increase from 76.4 kN-m and 84.9 kN-m for member SH-P0-f1.0-L1-S1(D13) to 96.6 kN-m and 100.7 kN-m for member SH-P0-f1.5-L1-S1(D13).</p><p>In the case where the longitudinal reinforcement is increased from 4 D-10 bars to 4 D-13 bars, the peak tor- sional moment is seen to vary from 104.6 kN-m and 87.2 kN-m for member SH-P0-f1.5-L1-S1(D10) to 96.6 kN-m and 100.7 kN-m for member SH-P0-f1.5-L1-S1(D13). This means that the increase of the longitudinal reinforcement has no effect on the increase of the torsional resistance.</p><p>For the transverse reinforcement, when the number of stirrups is doubled, the peak torsional moment is seen to change from 104.6 kN-m and 87.2 kN-m for member SH-P0-f1.5-L1-S1(D10) to 97.5 kN-m and 104.7 kN-m for member SH-P0-f1.5-L1-S2(D10). This indicates that, for the members considered in this study, the increment in the torsional resistance resulting from the increase of the stirrups is smaller than that resulting from the increase of the steel fiber content. Besides, the increase of the stirrups is seen to augment the ductility in the torsional mo- ment-angle of twist relation owing to the generation of a larger number of inclined cracks favoring the redistribu- tion of stress.</p><p>The change in the peak torsional moment according to the increase of the amount of steel fiber, increase of transverse reinforcement, and increase of longitudinal reinforcement is similar to that observed by Yang, Joh, Lee and Kim in their experimental study on UHPC beams with plain rectangular cross-section [<xref ref-type="bibr" rid="scirp.54784-ref28">28</xref>] .</p><p><xref ref-type="fig" rid="fig1">Figure 1</xref>2 plots the relation between the torsional moment and the angle of twist measured in the prestressed members. The torsional resistance is seen to increase significantly according to the amount of prestress. The peak torsional moment of member SH-P4-f1.5-L1-S1-1 with prestress of 12.5 MPa is 145.8 kN-m and becomes 190.6 kN-m and 187.9 kN-m for the two SH-P4-f1.5-L1-S1 members and 192.0 kN-m for member SH-P4-f1.5-L1-S1-2 with prestress of 25.0 MPa. However, brittle failure occurred after the peak value as compared to the cases with- out prestress.</p><fig id="fig11"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>1</label><caption><title> Torsional moment-angle of twist curve (torsional members without prestress)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x76.png"/></fig><fig id="fig12"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>2</label><caption><title> Torsional moment-angle of twist curve (torsional members with prestress)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x77.png"/></fig><p>Moreover, the peak torsional moment of member SH-P4-f1.0-L1-S1-2 with prestress of 50.0 MPa is 212.8 kN-m. This indicates the larger increase of the peak torsional moment even with a small steel fiber volume frac- tion of 1.0% compared to the case with small prestress and steel fiber volume fraction of 1.5%. For example, the identical member SH-P4-f1.0-L1-S1-1, which underwent reduction of its prestress force due to the dysfunction of the hydraulic jack during the jacking of the prestressing tendon, resisted only up to a peak torsional moment of 167.5 kN-m.</p></sec><sec id="s4_3"><title>4.3. Comparative Analysis with the Results Predicted by Design Formula</title><p><xref ref-type="table" rid="table4">Table 4</xref> compares the values of the cracking torque <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x78.png" xlink:type="simple"/></inline-formula> and ultimate torsional moment <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x78.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x79.png" xlink:type="simple"/></inline-formula> obtained experi- mentally and predicted analytically using Equations (13) and (9). The ultimate torsional moments computed using the calibrated <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x78.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x79.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x80.png" xlink:type="simple"/></inline-formula> of the inclination angle and using the non-calibrated value of <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x78.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x79.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x80.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x81.png" xlink:type="simple"/></inline-formula> are both used for the com- parison.</p><p>For the cases without prestress, the inclined cracks should theoretically form an angle of 45˚ with the centerline of the member. However, slight deviation was reported in the observation of the shear test of beam members. Therefore, the value of the inclination angle <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x82.png" xlink:type="simple"/></inline-formula> is calibrated to correct this deviation. The Japanese provisional design guidelines for UHPC adopt a deviation of 5˚ for <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x82.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x83.png" xlink:type="simple"/></inline-formula> based on previous experimental data [<xref ref-type="bibr" rid="scirp.54784-ref30">30</xref>] . In the present study, an average deviation of 4.7˚ from the line inclined by 45˚ to the centerline of the beam was observed for the inclined cracks identified in the 8 members without prestress (<xref ref-type="table" rid="table3">Table 3</xref>).</p><p>Figures 13 compares the analytic and experimental values of the cracking torque<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x84.png" xlink:type="simple"/></inline-formula>. And <xref ref-type="fig" rid="fig1">Figure 1</xref>4 and <xref ref-type="fig" rid="fig1">Figure 1</xref>5 compare the analytic and experimental values of the ultimate torsional moment <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x84.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x85.png" xlink:type="simple"/></inline-formula> of the UHPC beam members tested in this study. <xref ref-type="fig" rid="fig1">Figure 1</xref>4 does not account the calibrated value <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x84.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x85.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x86.png" xlink:type="simple"/></inline-formula> of the inclination angle whereas <xref ref-type="fig" rid="fig1">Figure 1</xref>5 considers <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x84.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x85.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x86.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x87.png" xlink:type="simple"/></inline-formula> for<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x84.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x85.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x86.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x87.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/1-8102326x88.png" xlink:type="simple"/></inline-formula>.</p></sec></sec><sec id="s5"><title>5. Conclusions</title><p>This study proposed a prediction formula for the torsional strength enabling to reflect the tensile strength of ultra high performance concrete (UHPC) beams based upon the thin-walled tube theory. Torsion test was conducted on thin-walled UHPC box beams to validate the proposed formula through comparison of the predicted torsional</p><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> Comparison of experimental and predicted cracking torque (T<sub>cr</sub>) and ultimate torsional moment (T<sub>n</sub>)</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Specimen designation</th><th align="center" valign="middle"  colspan="2"  >T<sub>cr</sub> (kN-m)</th><th align="center" valign="middle"  colspan="3"  >T<sub>n</sub> (kN-m)</th></tr></thead><tr><td align="center" valign="middle" >Analysis</td><td align="center" valign="middle" >Test (photograph)</td><td align="center" valign="middle" >Analysis (q<sub>0</sub> accounted)</td><td align="center" valign="middle" >Analysis (q<sub>0</sub> not accounted)</td><td align="center" valign="middle" >Test (graph)</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >SH-P0-F1.5-L1-S1(D13)</td><td align="center" valign="middle" >73.2</td><td align="center" valign="middle" >68.4</td><td align="center" valign="middle" >100.1</td><td align="center" valign="middle" >118.2</td><td align="center" valign="middle" >96.6</td></tr><tr><td align="center" valign="middle" >73.2</td><td align="center" valign="middle" >79.1</td><td align="center" valign="middle" >100.1</td><td align="center" valign="middle" >118.2</td><td align="center" valign="middle" >100.7</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >SH-P2-F1.5-L1-S1</td><td align="center" valign="middle" >147.7</td><td align="center" valign="middle" >147.6</td><td align="center" valign="middle" >196.0</td><td align="center" valign="middle" >238.5</td><td align="center" valign="middle" >190.6</td></tr><tr><td align="center" valign="middle" >147.7</td><td align="center" valign="middle" >148.5</td><td align="center" valign="middle" >196.0</td><td align="center" valign="middle" >238.5</td><td align="center" valign="middle" >187.9</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >SH-P4-F1.5-L1-S1</td><td align="center" valign="middle" >116.6</td><td align="center" valign="middle" >115.2</td><td align="center" valign="middle" >157.7</td><td align="center" valign="middle" >188.2</td><td align="center" valign="middle" >145.8</td></tr><tr><td align="center" valign="middle" >147.7</td><td align="center" valign="middle" >157.5</td><td align="center" valign="middle" >196.0</td><td align="center" valign="middle" >238.5</td><td align="center" valign="middle" >192.0</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >SH-P0-F1-L1-S1</td><td align="center" valign="middle" >62.6</td><td align="center" valign="middle" >66.7</td><td align="center" valign="middle" >76.8</td><td align="center" valign="middle" >90.6</td><td align="center" valign="middle" >76.4</td></tr><tr><td align="center" valign="middle" >62.6</td><td align="center" valign="middle" >68.3</td><td align="center" valign="middle" >76.8</td><td align="center" valign="middle" >90.6</td><td align="center" valign="middle" >84.9</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >SH-P4-F1-L1-S1</td><td align="center" valign="middle" >165.1</td><td align="center" valign="middle" >165.6</td><td align="center" valign="middle" >190.4</td><td align="center" valign="middle" >245.0</td><td align="center" valign="middle" >167.5</td></tr><tr><td align="center" valign="middle" >165.1</td><td align="center" valign="middle" >144</td><td align="center" valign="middle" >190.4</td><td align="center" valign="middle" >245.0</td><td align="center" valign="middle" >212.8</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >SH-P0-F1.5-L1-S2</td><td align="center" valign="middle" >73.2</td><td align="center" valign="middle" >65.6</td><td align="center" valign="middle" >112.9</td><td align="center" valign="middle" >133.3</td><td align="center" valign="middle" >97.5</td></tr><tr><td align="center" valign="middle" >73.2</td><td align="center" valign="middle" >70.3</td><td align="center" valign="middle" >112.9</td><td align="center" valign="middle" >133.3</td><td align="center" valign="middle" >104.7</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >SH-P0-F1.5-L1-S1(D10)</td><td align="center" valign="middle" >73.2</td><td align="center" valign="middle" >64.7</td><td align="center" valign="middle" >100.1</td><td align="center" valign="middle" >118.2</td><td align="center" valign="middle" >104.6</td></tr><tr><td align="center" valign="middle" >73.2</td><td align="center" valign="middle" >64.0</td><td align="center" valign="middle" >100.1</td><td align="center" valign="middle" >118.2</td><td align="center" valign="middle" >87.2</td></tr></tbody></table></table-wrap><fig id="fig13"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>3</label><caption><title> Comparison of analytic and experimental crack- ing torque T<sub>cr</sub></title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x89.png"/></fig><fig id="fig14"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>4</label><caption><title> Comparison of analytic and experimental ultimate torsional moment T<sub>n</sub> (θ<sub>0</sub> not accounted)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x90.png"/></fig><fig id="fig15"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>5</label><caption><title> Comparison of analytic and experimental ultimate torsional moment T<sub>n</sub> (θ<sub>0</sub> accounted)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-8102326x91.png"/></fig><p>strength with the experimental results. The following conclusions can be drawn.</p><p>1) The thin-walled tube theory was adopted to derive the prediction formula of the torsional strength so as to reflect the contribution of the tensile strength of UHPC provided by the steel fibers to the torsional strength of the beam. The comparison of the predicted values of the cracking torque and torsional moment resistance with those observed in the torsional test of UHPC verified the validity of the design method.</p><p>2) The observation of the cracking and failure patterns revealed the occurrence of several additional inclined cracks after the initial cracks according to the increase of the load. The members exhibited post-cracking behavior with continuous increase of the load until the ultimate limit state. This indicated that the torsional behavior of the UHPC beams developed clear ductility owing to the steel fibers even after the initiation of cracks. However, the prestressed members showed brittle failure after the peak load.</p><p>3) The contribution of the steel fibers to the torsional strength and cracking load was larger than that of the stirrups, but the stirrups appeared to contribute additionally to the torsional ductility. Accordingly, it is recom- mended that design should exploit effectively the contribution of the steel fiber rather than arrange a larger num- ber of stirrups in UHPC structures subjected to torsion.</p><p>4) An average deviation of 4.7˚ from the theoretical angle of 45˚ predicted for the inclined cracks in the case of beam members without prestress. The consideration of this deviation enabled the prediction to approach more accurately the experimental data. The inclination angle of the inclined cracks reduced and the ultimate torsional strength increased with larger amount of prestress. Since the torsional resistance varied more sensitively to the change in the angle of the torsional cracks with larger prestress, attention should be paid on the computation of the crack angle in the design.</p></sec><sec id="s6"><title>Acknowledgements</title><p>This research was supported by a grant (14 AUDP-B069364-02) from Urban Architectural Research Program funded by Ministry of Land, Infrastructure and Transport of Korean Government.</p></sec><sec id="s7"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.54784-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">FHWA (US Federal Highway Administration) (2006) Material Property Characterization of Ultra High Performance Concrete. US Department of Transportation, Federal Highway Administration.</mixed-citation></ref><ref id="scirp.54784-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">AFGC (Association Franaise du Génie Civil) (2002) BétonsFibrés à Ultra-Hautes Performances. AFGC-SETRA.</mixed-citation></ref><ref id="scirp.54784-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Yang, I.H., Joh, C. and Kim, B.S. (2010) Structural Behavior of Ultrahigh Performance Concrete Beams Subjected to Bending. Engineering Structures, 32, 3478-3487.  
http://dx.doi.org/10.1016/j.engstruct.2010.07.017</mixed-citation></ref><ref id="scirp.54784-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Schydt, J., Herold, G. and Müller, H.S. (2008) Long Term Behavior of Ultra High Performance Concrete under the Attack of Chlorides and Aggressive Waters. Proceedings of the 2nd International Symposium on Ultra High Performance Concrete, 231-238.</mixed-citation></ref><ref id="scirp.54784-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Yang, I.H., Joh, C. and Kim, B.S. (2012) Flexural Response Predictions for Ultra High Performance Fiber-Reinforced Concrete Beams. Magazine of Concrete Research, 64, 113-127.  
http://dx.doi.org/10.1680/macr.10.00115</mixed-citation></ref><ref id="scirp.54784-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Yang, I.H., Joh, C. and Kim, B.S. (2011) Flexural Strength of Large Scale Ultra High Performance Concrete Prestressed T-beams. Canadian Journal of Civil Engineers, 38, 1185-1195.  
http://dx.doi.org/10.1139/l11-078</mixed-citation></ref><ref id="scirp.54784-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Ali, M.A. and White, R.N. (1999) Toward a Rational Approach for Design of Minimum Torsion Reinforcement. ACI Structural Journal, 96, 40-45.</mixed-citation></ref><ref id="scirp.54784-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Chiu, H.J., Fang, I.K., Young, W.T. and Shiau, J.K. (2007) Behavior of Reinforced Concrete Beams with Minimum Torsional Reinforcement. Engineering Structures, 29, 2193-2205. http://dx.doi.org/10.1016/j.engstruct.2006.11.004</mixed-citation></ref><ref id="scirp.54784-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Algorafi, M.A., Ali, A.A.A., Othman, I., Jaafar, M.S. and Anwar, M.P. (2010) Experimental Study of Externally Prestressed Segmental Beam under Torsion. Engineering Structures, 32, 3528-3538.  
http://dx.doi.org/10.1016/j.engstruct.2010.07.021</mixed-citation></ref><ref id="scirp.54784-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Lopes, S.M.R. and Bernardo, L.F.A. (2009) Twist Behavior of High-Strength Hollow Beams—Formation of Plastic Hinges along the Length. Engineering Structures, 31, 138-149.  
http://dx.doi.org/10.1016/j.engstruct.2008.08.003</mixed-citation></ref><ref id="scirp.54784-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Fang, I.K. and Shiau, J.K. (2004) Torsional Behavior of Normal- and High-Strength Concrete Beams. ACI Structural Journal, 101, 304-313.</mixed-citation></ref><ref id="scirp.54784-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Koutchoukali, N.E. and Belarbi, A. (2001) Torsion of High-Strength Reinforced Concrete Beams and Minimum Reinforcement Requirement. ACI Structural Journal, 98, 462-469.</mixed-citation></ref><ref id="scirp.54784-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Rasmussen, L.J. and Baker, G. (1995) Torsion in Reinforced Normal and High-Strength Concrete Beams. Part 1: Experimental Test Series. ACI Structural Journal, 92, 56-62.</mixed-citation></ref><ref id="scirp.54784-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Rasmussen, L.J. and Baker, G. (1995) Torsion in Reinforced Normal and High-Strength Concrete Beams. Part 2: Theory and Design. ACI Structural Journal, 92, 149-156.</mixed-citation></ref><ref id="scirp.54784-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Bernardo, L.F.A. and Lopes, S.M.R. (2009) Torsion in High-Strength Concrete Hollow Beams: Strength and Ductility Analysis. ACI Structural Journal, 106, 39-48.</mixed-citation></ref><ref id="scirp.54784-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Oh, B.H. (1992) Flexural Analysis of Reinforced Concrete Beams Containing Steel Fibers. Journal of Structural Engineering, 118, 2821-2836.  
http://dx.doi.org/10.1061/(ASCE)0733-9445(1992)118:10(2821)</mixed-citation></ref><ref id="scirp.54784-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Issa, M.S., Metwally, I.M. and Elzeiny, S.M. (2011) Influence of Fibers on Flexural Behavior and Ductility of Concrete Beams Reinforced with GFRP Rebars. Engineering Structures, 33, 1753-1763.  
http://dx.doi.org/10.1016/j.engstruct.2011.02.014</mixed-citation></ref><ref id="scirp.54784-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Campione, G. and Mangiavillano, M.L. (2008) Fibrous Reinforced Concrete Beams in Flexure: Experimental Investigation, Analytical Modeling and Design Considerations. Engineering Structures, 30, 2970-2980.  
http://dx.doi.org/10.1016/j.engstruct.2008.04.019</mixed-citation></ref><ref id="scirp.54784-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Mansur, M.A., Ong, K.C.G. and Paramasivam, P. (1986) Shear Strength of Fibrous Concrete Beams without Stirrups. Journal of Structural Engineering, 112, 2066-2079. http://dx.doi.org/10.1061/(ASCE)0733-9445(1986)112:9(2066)</mixed-citation></ref><ref id="scirp.54784-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Meda, A., Minelli, F., Plizzari, G.A. and Riva, P. (2005) Shear Behavior of Steel Fibre Reinforced Concrete Beams. Materials and Structures, 38, 343-351.</mixed-citation></ref><ref id="scirp.54784-ref21"><label>21</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Nanni</surname><given-names> A. </given-names></name>,<etal>et al</etal>. (<year>1990</year>)<article-title>Design for Torsion Using Steel Fiber Reinforced Concrete</article-title><source> ACI Structural Journal</source><volume> 87</volume>,<fpage> 556</fpage>-<lpage>564</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.54784-ref22"><label>22</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>EI-Niema</surname><given-names> E.I. </given-names></name>,<etal>et al</etal>. (<year>1993</year>)<article-title>Fiber Reinforced Concrete Beams under Torsion</article-title><source> ACI Structural Journal</source><volume> 90</volume>,<fpage> 489</fpage>-<lpage>495</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.54784-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Gunneswara, T.D. and Seshu, R.R. (2003) Torsion of Steel Fiber Reinforced Concrete Members. Cement and Concrete Research, 33, 1783-1788.  
http://dx.doi.org/10.1016/S0008-8846(03)00174-1</mixed-citation></ref><ref id="scirp.54784-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Narayanan, R. and Kareem-Palanjian, A.S. (1985) Torsion in Beams Reinforced with Bars and Fibers. Journal of Structural Engineering, 112, 53-66.  
http://dx.doi.org/10.1061/(ASCE)0733-9445(1986)112:1(53)</mixed-citation></ref><ref id="scirp.54784-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Mansur, M.A. (1982) Bending-Torsion Interaction for Concrete Beams Reinforced with Steel Fibres. Magazine of Concrete Research, 34, 182-190.  
http://dx.doi.org/10.1680/macr.1982.34.121.182</mixed-citation></ref><ref id="scirp.54784-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">Chalioris, C.E. and Karayannis, C.G. (2009) Effectiveness of the Use of Steel Fibres on the Torsional Behaviour of Flanged Concrete Beams. Cement &amp; Concrete Composites, 31, 331-341.  
http://dx.doi.org/10.1016/j.cemconcomp.2009.02.007</mixed-citation></ref><ref id="scirp.54784-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">ACI Committee 318-11 (2011) Building Code Requirements for Structural Concrete and Commentary. American Concrete Institute.</mixed-citation></ref><ref id="scirp.54784-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">Yang, I.H., Joh, C., Lee, J.W. and Kim, B.S. (2013) Torsional Behavior of Ultra-High Performance Concrete Squared Beams. Engineering Structures, 56, 372-383.  
http://dx.doi.org/10.1016/j.engstruct.2013.05.027</mixed-citation></ref><ref id="scirp.54784-ref29"><label>29</label><mixed-citation publication-type="other" xlink:type="simple">Collins, M.P. and Mitchell, D. (1990) Prestressed Concrete Structures. Prentice Hall, Englewood Cliffs.</mixed-citation></ref><ref id="scirp.54784-ref30"><label>30</label><mixed-citation publication-type="other" xlink:type="simple">JSCE (2004) Recommendations for Design and Construction of Ultra High-Strength Fiber-Reinforced Concrete Structures-Draft.</mixed-citation></ref></ref-list></back></article>