<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">ENG</journal-id><journal-title-group><journal-title>Engineering</journal-title></journal-title-group><issn pub-type="epub">1947-3931</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/eng.2014.613089</article-id><article-id pub-id-type="publisher-id">ENG-52684</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Evaluation of the Shear Strength of Perfobond Rib Connectors in Ultra High Performance Concrete
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>ae</surname><given-names>Yoon Kang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jong</surname><given-names>Sup Park</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Woo</surname><given-names>Tai Jung</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Moon</surname><given-names>Seoung Keum</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Structural Engineering Research Division, Korea Institute of Civil Engineering and Building Technology, 
Goyang, Korea</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>jykang@kict.re.kr(AYK)</email>;<email>jspark1@kict.re.kr(JSP)</email>;<email>woody@kict.re.kr(WTJ)</email>;<email>moonseoung@kict.re.kr(MSK)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>08</day><month>12</month><year>2014</year></pub-date><volume>06</volume><issue>13</issue><fpage>989</fpage><lpage>999</lpage><history><date date-type="received"><day>26</day>	<month>September</month>	<year>2014</year></date><date date-type="rev-recd"><day>24</day>	<month>October</month>	<year>2014</year>	</date><date date-type="accepted"><day>15</day>	<month>November</month>	<year>2014</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Since the previous strength prediction models for the perfobond rib connector were proposed based upon the results of push-out tests conducted on concretes with compressive strength below 50 MPa, push-out test is performed on perfobond shear connectors applying ultra high performance concretes with compressive strength higher than 80 MPa to evaluate their shear resistance. The test variables are chosen to be the diameter and number of dowel holes and, the change in the shear strength of the perfobond rib connector is examined with respect to the strength of two types of UHPC: steel fiber-reinforced concrete with compressive strength of 180 MPa and concrete without steel fiber with compressive strength of 80 MPa. The test results reveal that higher concrete strength and larger number of holes increased the shear strength, and that higher increase rate in the shear strength was achieved by the dowel action. The comparison with the predictions obtained by the previous models shows that the experimental results are close to the values given by the model proposed by Oguejiofor and Hosain [1].
 
</p></abstract><kwd-group><kwd>Perfobond Rib Connector</kwd><kwd> Ultra High Performance Concrete</kwd><kwd> Push-Out Test</kwd><kwd> Shear Strength</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>The most popular shear connector used in composite structures is the headed stud. However, this connector is vulnerable to fatigue and is prone to sudden failure through breakage in the weld of the stud. Accordingly, preference has been recently shifted to stiffer shear connectors like the perfobond rib. The perfobond rib is fabricated by boring a number of holes in a steel plate so as realize a structure with improved shear performance by exploiting the dowel action generated by concrete placed in the holes.</p><p><xref ref-type="fig" rid="fig1">Figure 1</xref> illustrates the mechanical elements resisting shear in the perfobond rib connector involving the shear resistance in the concrete dowel, the shear resistance of the transverse steel reinforcement and, the concrete bearing pressure over the whole steel plate.</p></sec><sec id="s2"><title>2. Review of Strength Prediction Models for Perfobond Rib Connector</title><p>Oguejiofor and Hosain [<xref ref-type="bibr" rid="scirp.52684-ref1">1</xref>] , Medberry and Shahrooz [<xref ref-type="bibr" rid="scirp.52684-ref2">2</xref>] , Verissimo et al. [<xref ref-type="bibr" rid="scirp.52684-ref3">3</xref>] , Al-Darzi et al. [<xref ref-type="bibr" rid="scirp.52684-ref4">4</xref>] and, Ahn et al. [<xref ref-type="bibr" rid="scirp.52684-ref5">5</xref>] conducted push-out test to propose different empirical models evaluating the strength of the perfobond rib connector. Ushijima et al. [<xref ref-type="bibr" rid="scirp.52684-ref6">6</xref>] and Cho et al. [<xref ref-type="bibr" rid="scirp.52684-ref7">7</xref>] suggested evaluation formulae accounting for the contribution of the concrete dowel action to the shear resistance in the perfobond rib connector. In <xref ref-type="table" rid="table1">Table 1</xref> arranging these models, it can be seen that the shear is predicted by summing up distinctive terms relating separately the shear resistance contributed by the end bearing pressure, by the concrete dowel and, by the transverse steel reinforcement.</p><p><xref ref-type="fig" rid="fig2">Figure 2</xref> compares the shear strength predictions of each model assuming a perfobond rib with plate thickness t = 15 mm, plate height h = 100 mm and, hole diameter D = 30 mm. The comparison shows that the model of Oguejiofor and Hosain [<xref ref-type="bibr" rid="scirp.52684-ref1">1</xref>] predicts relatively larger strength whereas Verissimo et al. [<xref ref-type="bibr" rid="scirp.52684-ref3">3</xref>] provides a lower bound and, the formula of Ahn et al. [<xref ref-type="bibr" rid="scirp.52684-ref5">5</xref>] gives median prediction.</p><p>Moreover, <xref ref-type="fig" rid="fig3">Figure 3</xref> compares the shear strength calculated for concrete with compressive strength of 80 MPa. It can be seen that the shear strength computed for the perfobond rib connector is approximately 1.6 to 3.7 times larger than that of the stud defined in Eurocode.</p><p>It is noteworthy that most of the prediction models were established based upon push-out test for concrete with compressive strength running around 27 MPa. Since only Ahn et al. [<xref ref-type="bibr" rid="scirp.52684-ref5">5</xref>] considered concretes with com-</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Shear-resisting mechanism of perfobond rib</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x6.png"/></fig><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Strength prediction models for perfobond rib</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Authors</th><th align="center" valign="middle" >Strength prediction models</th></tr></thead><tr><td align="center" valign="middle" >Oguejiofor and Hosain [<xref ref-type="bibr" rid="scirp.52684-ref1">1</xref>]</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/11-8102259x7.png" xlink:type="simple"/></inline-formula></td></tr><tr><td align="center" valign="middle" >Medberry and Shahrooz [<xref ref-type="bibr" rid="scirp.52684-ref2">2</xref>]</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/11-8102259x8.png" xlink:type="simple"/></inline-formula></td></tr><tr><td align="center" valign="middle" >Verissimo et al. [<xref ref-type="bibr" rid="scirp.52684-ref3">3</xref>]</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/11-8102259x9.png" xlink:type="simple"/></inline-formula></td></tr><tr><td align="center" valign="middle" >Al-Darzi et al. [<xref ref-type="bibr" rid="scirp.52684-ref4">4</xref>]</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/11-8102259x10.png" xlink:type="simple"/></inline-formula></td></tr><tr><td align="center" valign="middle" >Ahn et al. [<xref ref-type="bibr" rid="scirp.52684-ref5">5</xref>]</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/11-8102259x11.png" xlink:type="simple"/></inline-formula></td></tr></tbody></table></table-wrap><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Comparison of shear strength of perfobond rib connector predicted by previous models</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x12.png"/></fig><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> Comparison of shear strength computed for concrete with compressive strength of 80 MPa</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x13.png"/></fig><p>pressive strength up to 50 MPa in their experiments, the applicability of these shear connector strength prediction models for high strength concrete and, particularly steel fiber-reinforced ultra high strength concrete, should be examined experimentally.</p><p>On the behavior of stud connector in high strength concrete, An and Cederwall [<xref ref-type="bibr" rid="scirp.52684-ref8">8</xref>] conducted push-out tests to understand the strength of a stud depends on the concrete property with compressive strength of 100 MPa. They concluded that the stud in the high strength concrete tends to be sheared-off from the steel beam at the maximum load, while it shows very ductile behavior of stud in the normal strength concrete. As headed studs don’t have enough shear capacity in high strength concrete, a continuous shear connectors such as puzzle strip has been suggested. Hegger et al. [<xref ref-type="bibr" rid="scirp.52684-ref9">9</xref>] investigated load-carrying behavior of puzzle strip connectors in ultra high performance concrete with compressive strength of 180 MPa, and they reported that the continuous type of shear connectors like the puzzle strip are appropriate for the high strength concrete as it is capable of carrying high shear loads with an appropriate ductility.</p></sec><sec id="s3"><title>3. Push-Out Test of Perfobond Rib Connector Using Ultra High Performance Concrete</title><sec id="s3_1"><title>3.1. Objectives of Test</title><p>The previous strength prediction models proposed for the perfobond rib connector were established based on experiments conducted on concretes with compressive strength lower than 50 MPa. Therefore, the establishment of a strength prediction model for the perfobond rib connector using ultra high performance concrete (UHPC) with compressive strength higher than 80 MPa needs to rely on the results of push-out test using such concrete. Accordingly, this study performs push-out test on mixes with compressive strengths of 80 MPa and 180 MPa, and compares the experimental results with the predictions of the previous models.</p></sec><sec id="s3_2"><title>3.2. Test Variables and Material Properties</title><p>The basic dimensions of the perfobond rib are a thickness (t) of 12 mm, a height (h) of 100 mm, and a length (L) of 310 mm. The considered test variables arranged in <xref ref-type="table" rid="table2">Table 2</xref> are the number of holes and their diameter. For each test variable, two series of specimens were fabricated using two types of concrete with respective block compressive strength of 80 MPa and 180 MPa. The 180-MPa perfobond specimens were fabricated using UHPC reinforced with steel fiber at a ratio of 1.5% and exhibited a mean compressive strength of about 176.9 MPa in the cylinder test. The 80-MPa perfobond specimens were fabricated using high strength concrete mixed with 20- mm coarse aggregate and blast furnace slag and without steel fiber reinforcement. These specimens developed a mean compressive strength of approximately 80.1 MPa in the cylinder test.</p></sec><sec id="s3_3"><title>3.3. Test Method</title><p>Loading was applied stepwise by displacement control under initial application of a load of 5 kN for stabilization. The loading range and speed at each loading stage are listed in <xref ref-type="table" rid="table3">Table 3</xref>.</p><p>The measurands of the tests are the relative slip between the steel girder and the concrete block measured at 2 spots in the front face and 2 spots in the rear face, the horizontal displacement of the concrete blocks measured at each center of the two blocks, and the vertical displacement of the steel girder measured at 1 spot at the center of the girder. <xref ref-type="fig" rid="fig4">Figure 4</xref> shows the layout of the 7 displacement sensors installed on the specimen. <xref ref-type="fig" rid="fig5">Figure 5</xref> pre- sents scenes of the test setup.</p></sec><sec id="s3_4"><title>3.4. Test Results</title><p><xref ref-type="fig" rid="fig6">Figure 6</xref> and <xref ref-type="fig" rid="fig7">Figure 7</xref> plot the load-relative slip curves for each specimen. For the comparison of the shear strengths obtained experimentally and from the prediction models, the characteristic load (P<sub>rk</sub>) is calculated as</p><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Test variables of perfobond rib specimens</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Specimen designation</th><th align="center" valign="middle" >No. of holes</th><th align="center" valign="middle" >Diameter of hole (mm)</th><th align="center" valign="middle" >Plate thickness (mm)</th><th align="center" valign="middle" >Shape of shear connector</th></tr></thead><tr><td align="center" valign="middle" >P12</td><td align="center" valign="middle" >?</td><td align="center" valign="middle" >?</td><td align="center" valign="middle" >12</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/11-8102259x14.png" xlink:type="simple"/></inline-formula></td></tr><tr><td align="center" valign="middle" >P12-D30x1</td><td align="center" valign="middle" >1</td><td align="center" valign="middle" >30</td><td align="center" valign="middle" >12</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/11-8102259x15.png" xlink:type="simple"/></inline-formula></td></tr><tr><td align="center" valign="middle" >P12-D30x2</td><td align="center" valign="middle" >2</td><td align="center" valign="middle" >30</td><td align="center" valign="middle" >12</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/11-8102259x16.png" xlink:type="simple"/></inline-formula></td></tr><tr><td align="center" valign="middle" >P12-D30x3</td><td align="center" valign="middle" >3</td><td align="center" valign="middle" >30</td><td align="center" valign="middle" >12</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/11-8102259x17.png" xlink:type="simple"/></inline-formula></td></tr><tr><td align="center" valign="middle" >P12-D50x1</td><td align="center" valign="middle" >1</td><td align="center" valign="middle" >50</td><td align="center" valign="middle" >12</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/11-8102259x18.png" xlink:type="simple"/></inline-formula></td></tr><tr><td align="center" valign="middle" >P12-D50x2</td><td align="center" valign="middle" >2</td><td align="center" valign="middle" >50</td><td align="center" valign="middle" >12</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/11-8102259x19.png" xlink:type="simple"/></inline-formula></td></tr><tr><td align="center" valign="middle" >P12-D50x3</td><td align="center" valign="middle" >3</td><td align="center" valign="middle" >50</td><td align="center" valign="middle" >12</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/11-8102259x20.png" xlink:type="simple"/></inline-formula></td></tr></tbody></table></table-wrap><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Loading range and speed per loading stage of push-out test</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Loading stage</th><th align="center" valign="middle" >Loading range</th><th align="center" valign="middle" >Loading speed (mm/s)</th><th align="center" valign="middle" >Remarks</th></tr></thead><tr><td align="center" valign="middle" >Stage 1 Stage 2 Stage 3 Stage 4 Stage 5 Stage 6</td><td align="center" valign="middle" >5 kN 3 mm 6 mm 10 mm 20 mm &gt;20 mm</td><td align="center" valign="middle" >? 0.004 0.006 0.01 0.04 0.06</td><td align="center" valign="middle" >Stabilization load (zeroing) ? ? ? ? Until failure</td></tr></tbody></table></table-wrap><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> Layout of displacement sensors</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x21.png"/></fig><fig-group id="fig5"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> Views of push-out test: front (left), rear (right).</title></caption><fig id ="fig5_1"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x22.png"/></fig><fig id ="fig5_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x23.png"/></fig></fig-group><p>90% of the ultimate load (P<sub>u</sub>) based on Eurocode. <xref ref-type="table" rid="table4">Table 4</xref> arranges the experimental results for each specimen.</p><p>The results are rearranged in <xref ref-type="fig" rid="fig8">Figure 8</xref> in which the shear strength is seen to increase with larger number of holes and higher compressive strength of concrete. Larger diameter of the holes appears to enlarge the dowel ac-</p><fig-group id="fig6"><label><xref ref-type="fig" rid="fig6">Figure 6</xref></label><caption><title> Measured load-relative slip curves (180-MPa perfobond rib specimens, load per 2 perfobond ribs). (a) C180-P12; (b) C180-P12-D30x1; (c) C180-P12-D30x2; (d) C180-P12-D30x3; (e) C180-P12-D50x1; (f) C180-P12-D50x2; (g) C180- P12-D50x3.</title></caption><fig id ="fig6_1"><label>(b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x24.png"/></fig><fig id ="fig6_2"><label> (c)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x25.png"/></fig><fig id ="fig6_3"><label>(d)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x26.png"/></fig><fig id ="fig6_4"><label> (e)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x27.png"/></fig><fig id ="fig6_5"><label>(f)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x28.png"/></fig><fig id ="fig6_6"><label> (h)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x29.png"/></fig><fig id ="fig6_7"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x30.png"/></fig></fig-group><fig-group id="fig7"><label><xref ref-type="fig" rid="fig7">Figure 7</xref></label><caption><title> Measured load-relative slip curves (80-MPa perfobond rib specimens, load per 2 perfobond ribs). (a) C80-P12; (b) C80-P12-D30x1; (c) C80-P12-D30x2; (d) C80-P12-D30x3; (e) C80-P12-D50x1; (f) C80-P12-D50x2; (g) C80-P12-D50x3.</title></caption><fig id ="fig7_1"><label>(b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x31.png"/></fig><fig id ="fig7_2"><label> (c)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x32.png"/></fig><fig id ="fig7_3"><label>(d)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x33.png"/></fig><fig id ="fig7_4"><label> (e)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x34.png"/></fig><fig id ="fig7_5"><label>(f)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x35.png"/></fig><fig id ="fig7_6"><label> (h)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x36.png"/></fig><fig id ="fig7_7"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x37.png"/></fig></fig-group><fig-group id="fig8"><label><xref ref-type="fig" rid="fig8">Figure 8</xref></label><caption><title> Change in shear strength according to number of holes. (a) 180-MPa strength; (b) 80-MPa strength.</title></caption><fig id ="fig8_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x38.png"/></fig><fig id ="fig8_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x39.png"/></fig></fig-group><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> Push-out test results of perfobond rib specimens using high strength concretes</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Specimens</th><th align="center" valign="middle"  rowspan="2"  >Concrete strength (MPa)</th><th align="center" valign="middle"  rowspan="2"  >No. of holes</th><th align="center" valign="middle"  rowspan="2"  >Diameter of hole (mm)</th><th align="center" valign="middle"  rowspan="2"  >Ultimate load, P<sub>u</sub> (kN)</th><th align="center" valign="middle"  rowspan="2"  >Relative slip, δ<sub>u</sub> (mm)</th><th align="center" valign="middle"  colspan="2"  >Characteristic values</th><th align="center" valign="middle"  rowspan="2"  >Ductility, δ<sub>uk</sub>/δ<sub>u</sub></th></tr></thead><tr><td align="center" valign="middle" >Load, P<sub>rk</sub> (kN)</td><td align="center" valign="middle" >Relative slip, δ<sub>uk</sub> (mm)</td></tr><tr><td align="center" valign="middle" >C180-P12 C180-P12-D30x1 C180-P12-D30x2 C180-P12-D30x3 C180-P12-D50x1 C180-P12-D50x2 C180-P12-D50x3</td><td align="center" valign="middle" >180</td><td align="center" valign="middle" >? 1 2 3 1 2 3</td><td align="center" valign="middle" >? 30 30 30 50 50 50</td><td align="center" valign="middle" >730.0 1011.0 962.3 963.0 1032.3 1051.8 1135.0</td><td align="center" valign="middle" >8.34 6.57 9.34 2.29 5.05 7.76 13.46</td><td align="center" valign="middle" >657.0 909.9 866.1 866.7 929.1 946.6 1021.5</td><td align="center" valign="middle" >14.38 14.93 13.22 6.18 7.38 10.70 19.03</td><td align="center" valign="middle" >1.78 2.27 1.42 2.70 1.46 1.37 1.41</td></tr><tr><td align="center" valign="middle" >C80-P12 C80-P12-D30x1 C80-P12-D30x2 C80-P12-D30x3 C80-P12-D50x1 C80-P12-D50x2 C80-P12-D50x3</td><td align="center" valign="middle" >80</td><td align="center" valign="middle" >? 1 2 3 1 2 3</td><td align="center" valign="middle" >? 30 30 30 50 50 50</td><td align="center" valign="middle" >416.6 368.8 474.9 575.3 535.0 613.7 754.7</td><td align="center" valign="middle" >0.84 1.76 1.04 1.32 0.61 3.68 1.73</td><td align="center" valign="middle" >374.9 331.9 427.4 517.8 481.5 552.3 679.2</td><td align="center" valign="middle" >2.47 3.61 1.59 1.48 1.82 6.62 2.57</td><td align="center" valign="middle" >2.95 2.05 1.53 1.12 2.98 1.80 1.30</td></tr></tbody></table></table-wrap><p>tion, which in turn accentuates the tendency of the shear strength to increase. Furthermore, higher strength of concrete also promotes the increase of the shear strength by the dowel action. Here, specimen C80-P12-D30x1 applying 80-MPa concrete and with one dowel hole was expected to develop higher shear strength than specimen C80-P12 without hole but exhibited contrarily reduced shear strength. This result can be attributed to some problem in the fabrication of the specimen.</p></sec></sec><sec id="s4"><title>4. Comparison of Test Results and Previous Prediction Models</title><p>In order to verify the applicability of previous models for the prediction of the shear strength of UHPC exhibiting higher strength than conventional concrete, <xref ref-type="table" rid="table5">Table 5</xref> compares the experimental results to the shear strength predicted by these models. It can be observed that the experimental results approach well the predictions of the shear strength given by the model proposed by Oguejiofor and Hosain [<xref ref-type="bibr" rid="scirp.52684-ref1">1</xref>] and that the predictions of the model proposed by Medberry and Shahrooz [<xref ref-type="bibr" rid="scirp.52684-ref2">2</xref>] differ from the test results by maximum 2.33 times.</p><p><xref ref-type="fig" rid="fig9">Figure 9</xref> and <xref ref-type="fig" rid="fig1">Figure 1</xref>0 compare the increase pattern of the ultimate shear load of the test results to the shear strength curves provided by the previous prediction models. Here also, the model proposed by Oguejiofor and Hosain [<xref ref-type="bibr" rid="scirp.52684-ref1">1</xref>] approaches closely the test results. In <xref ref-type="fig" rid="fig9">Figure 9</xref>, the test results for the cases applying 2 and 4 headed studs are plotted concurrently. Their respective shear forces are 377.1 kN and 780.3 kN. This indicates that the</p><fig-group id="fig9"><label><xref ref-type="fig" rid="fig9">Figure 9</xref></label><caption><title> Comparison of shear prediction models (180-MPa concrete). (a) D = 30 mm; (b) D = 50 mm.</title></caption><fig id ="fig9_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x40.png"/></fig><fig id ="fig9_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x41.png"/></fig></fig-group><fig-group id="fig10"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>0</label><caption><title> Comparison of shear prediction models (80-MPa concrete). (a) D = 30 mm; (b) D = 50 mm.</title></caption><fig id ="fig10_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x42.png"/></fig><fig id ="fig10_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-8102259x43.png"/></fig></fig-group><table-wrap id="table5" ><label><xref ref-type="table" rid="table5">Table 5</xref></label><caption><title> Comparison of experimental and predicted shear capacities</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Specimens</th><th align="center" valign="middle"  colspan="5"  >Shear capacity per connector (kN)</th><th align="center" valign="middle"  rowspan="2"  >Test/(1)</th><th align="center" valign="middle"  rowspan="2"  >Test/(2)</th><th align="center" valign="middle"  rowspan="2"  >Test/(3)</th><th align="center" valign="middle"  rowspan="2"  >Test/(4)</th></tr></thead><tr><td align="center" valign="middle" >Test</td><td align="center" valign="middle" >Oguejiofor et al. (1)</td><td align="center" valign="middle" >Medberry et al. (2)</td><td align="center" valign="middle" >Verissimo et al. (3)</td><td align="center" valign="middle" >Ahn et al. (4)</td></tr><tr><td align="center" valign="middle" >C180-P12 C180-P12-D30x1 C180-P12-D30x2 C180-P12-D30x3 C180-P12-D50x1 C180-P12-D50x2 C180-P12-D50x3</td><td align="center" valign="middle" >730.0 1011.0 962.3 963.0 1032.3 1051.8 1135.0</td><td align="center" valign="middle" >972 1012 1052 1092 1083 1194 1305</td><td align="center" valign="middle" >419 434 450 466 462 506 550</td><td align="center" valign="middle" >582 610 639 668 661 741 820</td><td align="center" valign="middle" >678 714 750 786 778 878 978</td><td align="center" valign="middle" >0.75 1.00 0.91 0.88 0.95 0.88 0.87</td><td align="center" valign="middle" >1.74 2.33 2.14 2.07 2.23 2.08 2.06</td><td align="center" valign="middle" >1.25 1.66 1.51 1.44 1.56 1.42 1.38</td><td align="center" valign="middle" >1.08 1.42 1.28 1.23 1.33 1.20 1.16</td></tr><tr><td align="center" valign="middle" >C80-P12 C80-P12-D30x1 C80-P12-D30x2 C80-P12-D30x3 C80-P12-D50x1 C80-P12-D50x2 C80-P12-D50x3</td><td align="center" valign="middle" >416.6 368.8 474.9 575.3 535.0 613.7 754.7</td><td align="center" valign="middle" >432 458 485 512 506 580 654</td><td align="center" valign="middle" >298 309 319 330 327 357 386</td><td align="center" valign="middle" >258 278 297 315 311 365 418</td><td align="center" valign="middle" >301 325 349 373 368 435 501</td><td align="center" valign="middle" >0.96 0.81 0.98 1.12 1.06 1.06 1.15</td><td align="center" valign="middle" >1.40 1.19 1.49 1.74 1.64 1.72 1.96</td><td align="center" valign="middle" >1.61 1.33 1.60 1.83 1.72 1.68 1.81</td><td align="center" valign="middle" >1.38 1.13 1.36 1.54 1.45 1.41 1.51</td></tr></tbody></table></table-wrap><p>perfobond rib specimen C180-P12 without dowel hole develops shear strength comparable to the case applying 4 headed studs, and means that one perfobond rib provides a level of shear strength sufficient to replace 4 headed studs.</p><p>The specimens using concrete with compressive strength of 180 MPa in <xref ref-type="fig" rid="fig9">Figure 9</xref> are seen to develop shear strength lower by about 10% than that calculated by the prediction formula of Oguejiofor and Hosain [<xref ref-type="bibr" rid="scirp.52684-ref1">1</xref>] . The increase rate of the shear strength shows similar trend to the predictions according to the number of dowel holes. The specimens applying concrete with compressive strength of 80 MPa in <xref ref-type="fig" rid="fig1">Figure 1</xref>0 develop shear strength larger by 5% to 15% than the predictions. Larger difference in the shear strength can be observed compared to the predictions as much as the number of dowel holes increases.</p><p>Moreover, in all cases, the increase rate of the shear strength caused by the dowel action augmented with larger diameter of the dowel hole regardless of the compressive strength of concrete. The enlargement of the diameter of the holes appears to have larger influence on the increase of the dowel action in case of low com- pressive strength.</p></sec><sec id="s5"><title>5. Conclusions</title><p>This study conducted push-out test to measure the shear strength of the perfobond rib connector in ultra high performance concrete member with compressive strength of 80 MPa and 180 MPa and compared the results with those of previous prediction models. The test results revealed that the concrete dowel action provided by the holes of the perfobond rib did not show clear difference in the shear strength for the 180-MPa specimens whereas clear increase of the shear strength occurred owing to the dowel action in the 80-MPa specimens.</p><p>The comparison with the increase trend of the shear strength obtained by the prediction models indicated that the experimental results could be predicted using these models within their prediction range. Among these models, the formula proposed by Oguejiofor and Hosain [<xref ref-type="bibr" rid="scirp.52684-ref1">1</xref>] provided the most accurate predictions, and the model proposed by Ahn et al. [<xref ref-type="bibr" rid="scirp.52684-ref5">5</xref>] was seen to be conservative.</p><p>Considering the small number of specimens adopted in this study, it is presumptuous to suggest a model covering the strength range of ultra high performance concrete. However, the comparison of the previous shear strength prediction models enabled to assess the models applicable in design. It is expected that a shear strength prediction model for perfobond rib using ultra high performance concrete could be proposed through further tests considering diversified compressive strengths ranging between 80 and 180 MPa.</p></sec><sec id="s6"><title>Acknowledgements</title><p>This study was supported financially through the project “Development of SUPER Concrete with compressive strength of 80 - 180 MPa and its application (1st year)”. The authors express their gratitude for the support.</p></sec><sec id="s7"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.52684-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Ushijima, Y., Hosaka, T., Mitsuki, K., Watanabe, H., Tachibana, Y. and Hiragi, H. (2001) An Experimental Study on Shear Characteristics of Perfobond Strip and Its Rational Strength Equations. Proceedings of the International Symposium on Connections between Steel and Concrete, Stuttgart, 10-12 September 2001, 1066-1075.</mixed-citation></ref><ref id="scirp.52684-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Cho, J.R., Park, S.Y., Cho, K., Kim, S.T. and Kim, B.S. (2012) Pull-Out Test and Discrete Spring Model of Fibre-Reinforced Polymer Perfobond Rib Shear Connector. Canadian Journal of Civil Engineering, 39, 1311-1320. 
http://dx.doi.org/10.1139/cjce-2011-0573</mixed-citation></ref><ref id="scirp.52684-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Oguejiofor, E.C. and Hosain, M.U. (1994) A Parametric Study of Perfobond Rib Shear Connectors. Canadian Journal of Civil Engineering, 21, 614-625. http://dx.doi.org/10.1139/l94-063</mixed-citation></ref><ref id="scirp.52684-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Medberry, S.B. and Shahrooz, B.M. (2002) Perfobond Shear Connector for Composite Construction. Engineering Journal, 39, 2-12.</mixed-citation></ref><ref id="scirp.52684-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Verissimo, G.S., Valente, M.I.B., Paes, J.L.R., Cruz, P.J.S. and Fakury, R.H. (2006) Design and Experimental Analysis of a New Shear Connector for Steel and Concrete Composite Structures. Proceedings of the 3rd International Conference on Bridge Maintenance, Safety and Management, Porto, 16-19 July 2006, 68-72.</mixed-citation></ref><ref id="scirp.52684-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Al-Darzi, S.Y.K., Chen, A.R. and Liu, Y.Q. (2007) Finite Element Simulation and Parametric Studies of Perfobond Rib Connector. Iraqi Virtual Science Library (www.ivsl.org). American Journal of Applied Sciences, 4, 122-127. 
http://dx.doi.org/10.3844/ajassp.2007.122.127</mixed-citation></ref><ref id="scirp.52684-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Ahn, J.H., Lee, C.G., Won, J.H. and Kim, S.H. (2010) Shear Resistance of the Perfobond-Rib Shear Connector Depending on Concrete Strength and Rib Arrangement. Journal of Constructional Steel Research, 66, 1295-1307. 
http://dx.doi.org/10.1016/j.jcsr.2010.04.008</mixed-citation></ref><ref id="scirp.52684-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">An, L. and Cederwall, K. (1996) Push-Out Tests on Studs in High Strength and Normal Strength Concrete. Journal of Constructional Steel Research, 36, 15-29. http://dx.doi.org/10.1016/0143-974X(94)00036-H</mixed-citation></ref><ref id="scirp.52684-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Hegger, J., Gallwoszus, J. and Rauscher, S. (2009) Load-Carrying Behaviour of Connectors under Shear, Tension and Compression in Ultra High Performance Concrete. NSCC2009 Report, RWTH Aachen University, Institute of Structural Concrete, Aachen.</mixed-citation></ref></ref-list></back></article>