<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">SGRE</journal-id><journal-title-group><journal-title>Smart Grid and Renewable Energy</journal-title></journal-title-group><issn pub-type="epub">2151-481X</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/sgre.2013.41013</article-id><article-id pub-id-type="publisher-id">SGRE-28141</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Earth&amp;Environmental Sciences</subject><subject> Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Modeling, Control &amp; Fault Management of Microgrids
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>ehdi</surname><given-names>Moradian</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Faramarz</surname><given-names>Mahdavi Tabatabaei</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Sajad</surname><given-names>Moradian</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Department of Electrical Engineering, Sahand University of Technology, Tabriz, Iran</addr-line></aff><aff id="aff3"><addr-line>Department of Electrical Engineering, Iran University of Science and Technology, Tehran, Iran.</addr-line></aff><aff id="aff2"><addr-line>Saman Gostar Company (Distributor of SANTERNO, Italy), Tehran, Iran</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>M_Moradian86@yahoo.com(EM)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>26</day><month>02</month><year>2013</year></pub-date><volume>04</volume><issue>01</issue><fpage>99</fpage><lpage>112</lpage><history><date date-type="received"><day>September</day>	<month>11th,</month>	<year>2012</year></date><date date-type="rev-recd"><day>November</day>	<month>13th,</month>	<year>2012</year>	</date><date date-type="accepted"><day>November</day>	<month>20th,</month>	<year>2012</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
   In this paper, modeling and decentralize control principles of a MicroGrid (MG) whom equipped with three Distributed Generation (DG) systems (consist of: Solar Cell System (SCS), MicroTurbine System (MTS) and Wind Energy Conversion System (WECS)) is simulated. Three arrangement of load changing have investigated for the system. In first one the system doesn’t have transfer of power between MG and grid. In other two arrangements system have transfer of power between MG and utility grid. Of course in third case transfer of power between DG resources is considerable. Case study system is equipped by energy storage devices (battery bank) for each DG’s separately by means of increasing the MG reliability. For WECS and SCS, MPPT control and for MTS, voltage and frequency (V&amp;F) controller has designed. The purpose of this paper is load respond in MG and storage process of surplus energy by consider of load changing. MATLAB/Simulink and its libraries (mainly the Sim Power Systems toolbox) were employed in order to develop a simulation platform suitable for identifying MG control requirements. This paper reported a control and op- eration of MG in network tension by applying a three phase fault.
    <!--?xml:namespace prefix = o /-->
     
 
</p></abstract><kwd-group><kwd>Microgrid; Decentralize Control; Wind Energy Conversion System; Microturbine; Solar Cell</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Microgrid concept widely developed in countries such as USA, Canada, Japan and UK. It has been investigated and implemented [1,2]. The increase in researches due to benefits of this type of networks including provide the reliability and security of network and loads, high efficiency, environmentally friendly and self-healing [<xref ref-type="bibr" rid="scirp.28141-ref3">3</xref>]. In today’s power systems, very large problems including electricity production cost and also reduce of fossil fuel, on the other hand, the increasing pollution created from burning oil and gas and dramatically growth of demands has been increase the greenhouse gases in the air which is considered as a big threat for ozone layer. Because electricity costs much less and in some cases is zero (for DG Resources), so in today’s power systems used distributed energy resources (e.g. wind and sun are free resources to generate electricity). Another advantage of smart grid which it should be mentioned is loss reduction caused by power transmission line. Because one of the goals in smart grids is producing power by distributed energy resources and removed the power plant as much as possible. So with this, the line power flowing and its corresponding losses can be reduced to acceptable level. In recent years, many researches about structure, control and implementation of smart grids has been worked in laboratories. Control of MG and performance of energy storages have close relationships, which in this paper have been reviewed. By energy storage MG control can be more easily and the system reliability can be increased. A MG is a connection of distributed energy resources like: wind energy conversion, microturbine, fuel cell, PV arrays, Combined Heat and Power (CHP) and energy saving factors such as flywheel, batteries or Uninterruptable Power Supply (UPS) and power capacitors in low voltage power systems [<xref ref-type="bibr" rid="scirp.28141-ref4">4</xref>].</p><p>Basic structure of a typical MG is shown and discussed in [<xref ref-type="bibr" rid="scirp.28141-ref5">5</xref>].</p><p>Here is assumed that distributed generation sources have the ability to respond the loads. After disappearing network fault, synchronization operation performed and isolated network connected to Utility Power Source again [<xref ref-type="bibr" rid="scirp.28141-ref6">6</xref>].</p><p>In reference [<xref ref-type="bibr" rid="scirp.28141-ref7">7</xref>] a very simple scheme of a MG with three DG resources has been studied. In the article that was published in 2010, there is no mention and have not been analyzed the: DG resources structure, controllers of each micro source, fault occurrence in the grid and reaction of MG against the sudden event and also transferred power between DG’s.</p><p>Note that the decentralized control means that on each DG resources has been an independent controller and each of this resources performed control operations independently. May be the type of applied controller is different and even similar. Fault events that may lead to islanding of a distribution system are discussed in [<xref ref-type="bibr" rid="scirp.28141-ref8">8</xref>]. The work described in this paper regards the simulation and control of the MG equipped by three distributed energy storage device and local loads. Used distributed generations in this paper are consists of: WECS, SCS (with MPPT control strategies), and MTS (with voltage and frequency control strategy). The robustness of the tested control strategies were studied for disturbances taking place in the utility network, followed by a forced islanding of the MG. Experimental tests for islanding and synchronization were presented in [<xref ref-type="bibr" rid="scirp.28141-ref9">9</xref>]. Islanding of the MG can take place by unplanned events like faults in the utility network or by planned actions like maintenance requirements.</p></sec><sec id="s2"><title>2. Structure of Distributed Generation Systems</title><p>In <xref ref-type="fig" rid="fig1">Figure 1</xref> the general structure of a micro-distribution network is shown. The input power producing by distributed generation resources converted to electrical energy for network and load requirements. Control tasks are divided into two parts:</p><p>1) Input-Side Controller: which should be possible to take the maximum power from the input source. Naturally, the protection of input side converter must be in considered.</p><p>2) Grid-Side Controller: that can follow these tasks: a) Input active power control derived for network; b) Control of the reactive power transferred between network and micro-grid; c) DC link voltage control; d) Synchronization of network; e) Assurance of power quality injected to the network. Generally the network controller position is VSI, which both amplitude and phase of the output voltage are controlled. All items listed above are the basic features for the grid-side controller that these converters should have. Studied network in this paper consists of two distributed generation sources, which is briefly explains their structure.</p><p>3) Microgrids Internal Structure: According to given system studied in this article is including distribution generating resources of PV and MT. The structure of this two system and their relevant controlling parts are shown below. It is noteworthy that PV and Fuel Cell (FC) systems have similar hardware structures [10,11].</p><p>3.1) Photovoltaic and FC systems: As previously noted the PV and FC hardware structure is similar. Although voltage or current by FC and PV is low, but by binding a set of them together can increase the production levels and also can increase or decrease the voltage level by using DC-DC converters such as boost converter for increasing the voltage level.</p><p>Non-linear relationship between <img src="13-6401200\793c38cb-05c1-477b-944e-29a2abc37276.jpg" /> obtain from the below equation [<xref ref-type="bibr" rid="scirp.28141-ref12">12</xref>].</p><disp-formula id="scirp.28141-formula32301"><label>(1)</label><graphic position="anchor" xlink:href="13-6401200\ca5258be-ce97-4ec2-a4bb-5550554249fd.jpg"  xlink:type="simple"/></disp-formula><p>Which in it <img src="13-6401200\6332dd4c-41df-4c56-b17f-b9a2be8216f3.jpg" /> is short circuit current, <img src="13-6401200\4086b1df-384e-4033-bde5-0cdb61f43bed.jpg" />is reverse saturation current, <img src="13-6401200\a60379fa-5bad-49ac-9643-845ecc7ee7d4.jpg" />is series resistance and <img src="13-6401200\97a17fb9-a449-45e2-ae6c-463629e67e8a.jpg" /> is constant factor which is depends on the type of materials used in cell.</p><p>In this paper a silicon solar panel, (<img src="13-6401200\7b312f4c-92dd-4d44-8928-2cc72473755a.jpg" />) has been used. Sample model is constructed by Iranian Optical Fiber Fabrication Company (OFFC) that related table of its coefficients and parameters comes to <xref ref-type="table" rid="table">Table </xref>A1 [<xref ref-type="bibr" rid="scirp.28141-ref13">13</xref>].</p><p>According to related values Equation (1) is written as follows:</p><disp-formula id="scirp.28141-formula32302"><label>(2)</label><graphic position="anchor" xlink:href="13-6401200\a3f2f5f9-065c-4aec-b167-ab419bd7886d.jpg"  xlink:type="simple"/></disp-formula><p>Non-linear characteristics of <img src="13-6401200\e40b8e84-fd69-4843-9424-a478f9b4f8ed.jpg" /> and <img src="13-6401200\31ee1308-b80b-4d7a-9869-7c5161fe06f9.jpg" /> are shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>.<img src="13-6401200\8dfd0b53-cbcb-49d5-b041-264486ecacd3.jpg" /> are known as power and voltage of maximum power in <img src="13-6401200\74191971-e629-4b66-871a-947644c59079.jpg" /> cell. These Curves are:</p><p>By changing temperature, the coefficients will changes [<xref ref-type="bibr" rid="scirp.28141-ref12">12</xref>]. Two samples of these changes are estimated in Equations 3-a (70˚C) and 3-b (−20˚C).</p><disp-formula id="scirp.28141-formula32303"><label>(3-a)</label><graphic position="anchor" xlink:href="13-6401200\42fca97c-b566-4196-b079-cbd62a02d766.jpg"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.28141-formula32304"><label>(3-b)</label><graphic position="anchor" xlink:href="13-6401200\447c5a3b-40aa-410c-90e9-c9b7f1cd4687.jpg"  xlink:type="simple"/></disp-formula><p>For displaying MPPT technique in <img src="13-6401200\04aed0b4-b837-4cb3-9a10-531e7593221c.jpg" /> we act the way [<xref ref-type="bibr" rid="scirp.28141-ref14">14</xref>]: cell voltage with corresponding maximum power production by considering the open circuit voltage for different temperature show a dependency.</p><disp-formula id="scirp.28141-formula32305"><label>(4)</label><graphic position="anchor" xlink:href="13-6401200\0a227d2a-8afe-4f0d-9b86-f783d443e6c1.jpg"  xlink:type="simple"/></disp-formula><p>This equation shows MPPT technique which in it <img src="13-6401200\79a940e6-458a-4eef-942a-755f6f6fd0df.jpg" /> called voltage factor that for OFFC its value considered 0.71. This method for maximum power estimating is simple and fast.</p><p>Equivalent circuit to <img src="13-6401200\730c70d6-be33-4b33-b6df-774b8bf6129b.jpg" /> cell block shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>(a) which the related equation to non-linear <img src="13-6401200\461d8035-40ee-4865-a7df-a1e1eb3c6eeb.jpg" /> relationship is placement. Also a delay function to limit the current of rapid response to voltage controlled source and to improving the convergence responses is used.</p><p>For VMPPT its related equivalent circuit shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>(b). This block will calculate the open circuit voltage (By using <img src="13-6401200\aef4aa0f-b0f6-4a2f-97e6-b80ae6f7e384.jpg" /> and Equation (2)), then comprised it with PV output voltage and produces the fire command for the PWM block. The delay shown here is the same reason as in <xref ref-type="fig" rid="fig3">Figure 3</xref>(a).</p><p>Now we want to see the performance of this system in</p><p>connected to the grid-connected mode and with applying a controller in AC part according to what is seen in <xref ref-type="fig" rid="fig4">Figure 4</xref>. After increasing the voltage level by boost, we paralleled it by energy storage devices (That somehow we can call them UPS). We do this in order to increase reliability of system. Now it is necessary that DC voltage produced by inverter becomes AC. The purpose of the grid-side controller is to maintain DC link voltage at a constant value regardless production power range.</p><p>Vector control in a rotating reference frame with the line voltage vector is used. The purpose in this controller is regulation of DC voltage and reactive power control. Using the Park conversions, voltage equations can be controlled to reference frame d-q. The idea of control is taken from [<xref ref-type="bibr" rid="scirp.28141-ref10">10</xref>].</p><p><xref ref-type="fig" rid="fig5">Figure 5</xref> shows simulated model of grid-side controller. PI standard controllers are used in order to regulate the line current in rotational synchronous frame in internal control loop and DC voltage in external loop.</p><p><img src="13-6401200\a59e6c85-0757-49a9-bc35-69021cee675d.jpg" />is active part of current and <img src="13-6401200\a278cc07-f930-40e8-b6ea-0db0e8d499c1.jpg" /> is reactive section on current. In order to obtain a transformation from active power, the value of current reference <img src="13-6401200\0f4ed35d-13d4-4ba1-b83b-22229f0e9d8c.jpg" /> (reactive part) considered as zero. PLL used in figure is to synchronize converter frequency with main grid. It is assumed that the harmonics produced by switching is zero.</p></sec><sec id="s3"><title>3. Structure And Mts Control Model</title><p>Recently microturbines have been much attention because of their small size, relative low cost, repair and cheap maintenance and relatively simple control. Different dynamic models have been discussed for micro-turbines by Rowen, Hannet, Saha and Nern for combustion gas turbine [15-17]. In 1993 mathematical method of gas turbine by Rowen was developed [<xref ref-type="bibr" rid="scirp.28141-ref15">15</xref>]. While in 1993, Prime Mover Working Group by considering the control of speed, acceleration, fuel and temperature made this model wider [<xref ref-type="bibr" rid="scirp.28141-ref16">16</xref>]. MT used in this article is a small combustion turbine with an installed capacity 25 to 500 KW and a high rotation speed (between 50,000 to 120,000 rpm). This model includes the speed governor,</p><p>acceleration control block, fuel system control and temperature control. Single-shaft turbine model is considered. Power producer with a Permanent Magnet Synchronous Generator (PMSG) has two poles and smooth poles rotor. Because of high speed shaft, generators of an AC voltage source will be a high frequency (frequency angular higher than 100,000 rad/sec) [<xref ref-type="bibr" rid="scirp.28141-ref17">17</xref>]. Since turbines moves at high speed, so AC generator is a high-frequency generator which cannot be directly coupled the AC network [<xref ref-type="bibr" rid="scirp.28141-ref18">18</xref>]. One way to model a system of distributed generation MT, based on all classification system are three following separate parts [19,20]:</p><p>1) Module 1: mechanical system of turbine and fuel.</p><p>2) Module 2: PMSG and AC/DC rectifier and energy storage devices.</p><p>3) Module 3: AC/DC voltage source inverter, PWM controller.</p><p>Mechanical Model and MT Control Functions:</p><p>Based on Rowen and Hannet model, we examine the MT model. Dynamic equations of MTS in [<xref ref-type="bibr" rid="scirp.28141-ref15">15</xref>] are investigated.</p><p>According to the principle of energy conversion and ignore the inverter losses, total of instantaneous powers in output of AC terminal must be equal to the instant powers in dc terminal like.</p><disp-formula id="scirp.28141-formula32306"><label>(5)</label><graphic position="anchor" xlink:href="13-6401200\adc09e62-e0e5-4ce0-ad12-6037f9fb61bf.jpg"  xlink:type="simple"/></disp-formula><p>Which <img src="13-6401200\7734532d-a094-4fe0-9b49-e9e83f468434.jpg" /> and <img src="13-6401200\22aaf982-8af3-42ca-97c6-ffb65ce3dcbf.jpg" /> are dc link voltage and current.</p><p>VSI simplified model shows in <xref ref-type="fig" rid="fig6">Figure 6</xref>(a). The inverter which used in this essay is hysteresis model.</p><p>Diagram block of V&amp;F controlling model presented in <xref ref-type="fig" rid="fig6">Figure 6</xref>(b). <img src="13-6401200\0b5dbe2e-4100-45da-96ec-c99af17ac240.jpg" />and <img src="13-6401200\81a1f4fe-d25c-4ad5-b9bb-1a0d052b4000.jpg" /> are reference amounts. In order to have unit power factor, the amount of <img src="13-6401200\cba21729-790b-4ac4-89da-cb32555a77ee.jpg" /> is zero and <img src="13-6401200\82a0c394-bfcc-4ad9-b6fc-44c9a0f1e3fc.jpg" /> is 1 p.u. Voltage and frequency (V&amp;F) control has to regulate the voltage value at the Point of Common Coupling (PCC) and also the frequency of the whole grid.</p><p>Now MT model of distributed generation in gridconnected mode is shown in <xref ref-type="fig" rid="fig7">Figure 7</xref>. The produced frequency by inverter will have the equal amount of 50 Hz corresponding to the network.</p><p>LCL Filters in this paper is designed by the idea in [21,22].</p><p>Conceptual and technical solution of MG is presented in [23,24].</p></sec><sec id="s4"><title>4. Structure and WECS Control Model</title><p>Electrical wind generators are the equipment who converts wind to electrical energy. Different types of generators are used in wind turbines. For example small sized wind turbines are equipped by DC generators with capacity up to 90 kw (from 10 to 90).</p><p>In wind turbines modern systems three phase AC generators are customs [<xref ref-type="bibr" rid="scirp.28141-ref25">25</xref>].</p><p>General kind of AC generators who are used in modern wind turbines are:</p><p>1) Squirrel Cage Induction Generator (SCIG)</p><p>2) Wired Rotor Induction Generator (WRIG)</p><p>3) DoubleFed Induction Generator (DFIG)</p><p>4) Synchronous Generators with output excitation (SG)</p><p>5) Permanent Magnet Synchronous Generator (PMSG)</p><p>Synchronous Generator is a kind of generators who are used in some researches [26,27]. These generators could connect to wind turbine without any gearbox. These benefits are attractive by consider of maintenance and limited shelf life. Synchronous generators could to excite by electric or with permanent magnet rotor. By considering the above reasons, used generator in this paper is kind of PMSG.</p></sec><sec id="s5"><title>5. Simulation of WECS</title><p>This system is modeled by equations of wind turbine as could be seen in Equations below. In this paper a variable speed wind turbine is used. Wind speed 12 m/sec is considered. The parameters value of PMSG is shown in <xref ref-type="table" rid="table">Table </xref>A2. If the speed of wind was variable, WECS should be used the Buck/Boost converter. In this case the trigger signal should produce for two switches. This performance cause to system be complicated.</p><p>Equations for wind turbine are shown in below [<xref ref-type="bibr" rid="scirp.28141-ref28">28</xref>].</p><disp-formula id="scirp.28141-formula32307"><label>(6)</label><graphic position="anchor" xlink:href="13-6401200\d998fad0-52e3-41b7-9c66-6906fe55f8cc.jpg"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.28141-formula32308"><label>(7)</label><graphic position="anchor" xlink:href="13-6401200\61cf4a2a-c5a6-47b8-9e16-09b900e070df.jpg"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.28141-formula32309"><label>(8)</label><graphic position="anchor" xlink:href="13-6401200\279aaea6-8e7d-4e5f-8da1-bdbe575dd4e0.jpg"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.28141-formula32310"><label>(9)</label><graphic position="anchor" xlink:href="13-6401200\8f6d2445-7f4d-4c02-bd85-bbe5efd25c73.jpg"  xlink:type="simple"/></disp-formula><p>Output mechanical power in watt is shown in Equation (6). In this equation, <img src="13-6401200\dc162d6e-30b6-4521-bfcb-9b41e612ea88.jpg" />air density in (kg/m<sup>3</sup>), C<sub>p</sub>, performance coefficient, <img src="13-6401200\42db4144-5125-4297-8013-897d78f62ab5.jpg" />wind speed in m/sec, <img src="13-6401200\b5d43230-3326-4c9b-892b-f7764103ce69.jpg" />, tip speed ratio, <img src="13-6401200\7b1d1f58-3639-41f4-a25e-24879e09681d.jpg" />, pitch angle, <img src="13-6401200\f1a85497-964f-4392-abb4-4b1ad1000b2f.jpg" />, turbine swept area.</p><p>In Equation (7), the coefficients <img src="13-6401200\776004c5-dc16-44b9-a2db-cfbc9da36b4d.jpg" /> to <img src="13-6401200\0ca6de27-87cd-4e28-92c2-06468b1d2049.jpg" /> are: <img src="13-6401200\85cdaba4-0586-4e48-8c5b-386c61aabab2.jpg" /> and <img src="13-6401200\750bf752-2437-4f25-8f42-045c49cb02ae.jpg" /> [<xref ref-type="bibr" rid="scirp.28141-ref28">28</xref>].</p><p>In Equation (8), <img src="13-6401200\2a5ea6e5-d833-425e-bee8-29b95b3e6cdc.jpg" />is rotor radius in meter; w, angular speed in rad/sec the output torque of wind turbine is input of used PMSG.</p><p>In order to acquiring the output maximum power in WECS, we use the MPPT algorithm <xref ref-type="fig" rid="fig8">Figure 8</xref>.</p><p>Inverter’s in each DG’s are modeled base on SANTERNO products [<xref ref-type="bibr" rid="scirp.28141-ref29">29</xref>].</p><p>In this algorithm, the initial value adjusted for DC references voltage. Correspondingly, voltage and current will be measured. After the measurement, DC output power (Po) would be calculated. In next step, the reference voltage ought to be altered as much as dc variations<img src="13-6401200\219218a1-32dd-412a-ace8-9dc1a72062d9.jpg" />. By this way:</p><disp-formula id="scirp.28141-formula32311"><label>(10)</label><graphic position="anchor" xlink:href="13-6401200\567dd703-25d0-4a61-bbd3-3fd4d5b9cc8d.jpg"  xlink:type="simple"/></disp-formula><p>Then dc power will calculated with <img src="13-6401200\8221bcbf-9163-4cc0-af22-df7e578780b1.jpg" />. If<img src="13-6401200\09b50a34-a8ef-4cb2-8e7e-64c1a4d10110.jpg" />, the system output isn’t in maximum point, so accordingly the reference voltage have to rise a quantum of <img src="13-6401200\7ba8d428-64fc-424e-9c8a-e43979056dfc.jpg" /> and power should compare with earlier amount<img src="13-6401200\5723bf4e-6eb7-4d64-a4b9-3d7b06edb3e1.jpg" />. This process continued till receiving to maximum point. Now if<img src="13-6401200\7b138b93-9b32-4b87-96d8-13426f5853b3.jpg" />, the reference voltage should decrease.</p><p>Value and parameters of boost model is shown in <xref ref-type="table" rid="table">Table </xref>A3.</p><p>In <xref ref-type="fig" rid="fig9">Figure 9</xref> MPPT block of WECS is shown. This block should produce the trigger signal of switches in DC link for tracking the maximum power.</p><p>In <xref ref-type="fig" rid="fig1">Figure 1</xref>0(a) Torque-Speed characteristics of WT is shown. Note that all of curves are in 12 m/sec wind speed.</p><p>As you see in <xref ref-type="fig" rid="fig1">Figure 1</xref>0(b), maximum amount of power coefficient in used turbine is 0.41 and<img src="13-6401200\e72b281e-efb8-4772-b4dd-186ce58b8656.jpg" />.</p><p>As we said, output power of WT is 7100 watt that is shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>0(d).</p><p>Produced torque of WT in system run time is 184 N.m.</p><p>DC link Voltage in battery bank terminal is shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>0(e). Voltage ripple is small. But it regulate in 243 volt. Battery bank capacity should be proportion to</p><p>produced power and connected load to the system. This signal is input of three phase inverter. In <xref ref-type="fig" rid="fig1">Figure 1</xref>1 gridconnected WECS is simulated. In t = 0.25 sec three phase fault (phase-phase) applied and the system goes to islanding mode.</p><p><xref ref-type="fig" rid="fig1">Figure 1</xref>2 has shown the output voltages before/after LCL filter.</p></sec></body><back><ref-list><title>References</title><ref id="scirp.28141-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">B. Lasseter, “Microgrids (Distributed Power Generation),” Proceedings of the IEEE PES Winter Meeting, Vol. 1, 2001, pp. 146-149.</mixed-citation></ref><ref id="scirp.28141-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">N. Hatziargyriou, H. Asano, R. Iravani and C. Marnay, “Microgrids: An Overview of Ongoing Research, Development, and Demonstration Projects,” IEEE Power Energy Magazine, Vol. 5, No. 4, 2007, pp. 78-94.  
doi:10.1109/MPAE.2007.376583</mixed-citation></ref><ref id="scirp.28141-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">M. Pipattanasomporn, H. Feroze and S. Rahman, “MultiAgent Systems in a Distributed Smart Grid: Design and Implementation,” Power Systems Conference and Exposition, Seattle, 15-18 March 2009, pp. 1-8.</mixed-citation></ref><ref id="scirp.28141-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Public Power Corporation, “Microgrids—Large Scale Integration of Micro-Generation to Low Voltage Grids,” Technical Annex, 2002.</mixed-citation></ref><ref id="scirp.28141-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">P. Piagi and R. H. Lasseter, “Autonomous Control of Microgrids,” IEEE PES Meeting, Montreal, June 2006.</mixed-citation></ref><ref id="scirp.28141-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">C. L. Moreira, F. O. Resende and J. A. P. Lopes, “Using Low Voltage MicroGrids for Service Restoration,” IEEE Transactions on Power Systems, Vol. 22, No. 1, 2007, pp. 395-403.</mixed-citation></ref><ref id="scirp.28141-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">R. Zamora and A. K. Srivastava, “Controls for Microgrids with Storage: Review, Challenges, and Research Needs,” Elsevier, Vol. 14, No. 7, 2010, pp. 2009-2018.</mixed-citation></ref><ref id="scirp.28141-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">F. Katiraei, M. R. Iravani and P. W. Lehn, “Microgrid Autonomous Operation during and Subsequent to Islanding Process,” IEEE Transactions on Power Delivery, Vol. 20, No. 1, 2005, pp. 248-257.</mixed-citation></ref><ref id="scirp.28141-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">D. Georgakis, S. Papathanassiou, N. Hatziargyriou, A. Engler and C. Hardt, “Operation of a Prototype Microgrid System Based on Micro-Sources Equipped with Fast-Acting Power Electronics Interfaces,” Proceedings of IEEE 35th PESC, Aachen, Vol. 4, 2004, pp. 2521-2526.</mixed-citation></ref><ref id="scirp.28141-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">F. Blaabjerg, R. Teodorescu, M. Liserre and A. V. Timbus, “Overview of Control and Grid Synchronization for Distributed Power Generation Systems,” IEEE Transactions on Industrial Electronics, Vol. 53, No. 5, 2006, pp. 1398-1409.</mixed-citation></ref><ref id="scirp.28141-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">M. Uzunoglu, O. C. Onar and M. S. Alam, “Modeling, Control and Simulation of a PV/FC/UC Based Hybrid Power Generation System for Stand-Alone Applications,” Renewable Energy, Vol. 34, No. 3, 2009, pp. 509-520.  
doi:10.1016/j.renene.2008.06.009</mixed-citation></ref><ref id="scirp.28141-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Z. M. Salameh, B. S. Borowy and A. R. A. Amin, “Photovoltaic Module-Site Matching Based on the Capacity Factors,” IEEE Transactions on Energy Conversion, Vol. 10, No. 2, 1995, pp. 326-332. doi:10.1109/60.391899</mixed-citation></ref><ref id="scirp.28141-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">http://www.solarserver.com/yellow-pages/companies/company-search/optical-fiber-solar-cell-fabrication-company.html</mixed-citation></ref><ref id="scirp.28141-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">M. A. Masoum, H. Dehbonei and E. F. Fuchs, “Theoretical and Experimental Analyses of Photovoltaic Systems with Voltageand Current-Based Maximum Power-Point Tracking,” IEEE Transactions on Energy Conversion, Vol. 22, No. 8, 2002, p. 62.</mixed-citation></ref><ref id="scirp.28141-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">W. I. Rowen, “Simplified Mathematical Representations of Heavy Duty Gas Turbines,” Journal of Engineering for Power, Vol. 105, No. 4, 1983, pp. 865-869. 
doi:10.1115/1.3227494</mixed-citation></ref><ref id="scirp.28141-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">L. N. Hannet and A. Khan, “Combustion Turbine Dynamic Model Validation from Tests,” IEEE Transactions on Power Systems, Vol. 8, No. 1, 1993, pp. 152-158.</mixed-citation></ref><ref id="scirp.28141-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">A. K. Saha, S. Chowdhury, S. P. Chowdhury and P. A. Crossley, “Modeling and Performance Analysis of a Microturbine as a Distributed Energy Resource,” IEEE Transactions on Energy Conversion, Vol. 24, No. 2, 2009, pp. 529-538.</mixed-citation></ref><ref id="scirp.28141-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Working Group on Prime Mover and Energy Supply Models for System Dynamic Performance Studies, “Dynamic Models for Combined Cycle Plants in Power System Studies,” IEEE Transactions on Power Systems, Vol. 9, No. 3, 1994, pp. 1698-1708. doi:10.1109/59.336085</mixed-citation></ref><ref id="scirp.28141-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">I. Zamora, J. S. Martin, A. Mazon, J. S. Martin and V. Aperribay, “Emergent Technologies in Electrical MicroGeneration,” International Journal of Emerging Electric Power Systems, Vol. 3, No. 2, 2005, pp. 1553-1779.</mixed-citation></ref><ref id="scirp.28141-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">C.-M. Ong, “Dynamic Simulation of Electric Machinery Using Matlab/Simulink,” Prentice Hall, Upper Saddle River, 1998.</mixed-citation></ref><ref id="scirp.28141-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">M. Malinowski, S. Stynski, W. Kolomyjski and M. P. Kazmierkowski, “Control of Tree-Level PWM Converter Applied to Variable Speed-Type Turbine,” IEEE Transactions on Industrial Electronics, Vol. 56, No. 1, 2009, pp. 69-77.</mixed-citation></ref><ref id="scirp.28141-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">M. Liserre, F. Blaabjerg and S. Hansen, “Design and Control of an LCL Filter-Based Three-Phase Active Rectifier,” IEEE Transactions on Industry Applications, Vol. 4, No. 5, 2005, pp. 1281-1291.</mixed-citation></ref><ref id="scirp.28141-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">J. A. P. Lopes, C. L. Moreira and A. G. Madureira, “Defining Control Strategies for MicroGrids Islanded Operation,” IEEE Transactions on Power Systems, Vol. 21, No. 2, 2006, pp. 916-924.</mixed-citation></ref><ref id="scirp.28141-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">R. H. Lasseter and P. Piagi, “Microgrid: A Conceptual Solution,” PESC’04, Aachen, 20-25 June 2004.</mixed-citation></ref><ref id="scirp.28141-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">T. Ackermann, “Wind Power in Power Systems,” John Wiley &amp; Sons, Chichester, 2005.  
doi:10.1002/0470012684</mixed-citation></ref><ref id="scirp.28141-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">A. J. G. Westlake, J. R. Bumby and E. Spooner, “Damping the Power-Angle Oscillations of a Permanent-Magnet Synchronous Generator with Particular Reference to Wind Turbine Applications,” IEE Proceedings of Electric Power Applications, Vol. 143, No. 3, 1996, pp. 269-280.</mixed-citation></ref><ref id="scirp.28141-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">L. Dambrosio and B. Fortunato, “One Step Ahead Adaptive Control Technique for a Wind Turbine-Synchronous Generator System,” Proceedings of the 32nd Intersociety Energy Conversion Engineering Conference, Honolulu, 27 July-1 August 1997, pp. 1970-1975.</mixed-citation></ref><ref id="scirp.28141-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">A. H. M. A. Rahim, M. A. Alam and M. F. Kandlawala, “Dynamic Performance Improvement of an Isolated Wind Turbine Induction Generator,” Computers and Electrical Engineering, Vol. 35, No. 4, 2009, pp. 594-607.  
doi:10.1016/j.compeleceng.2008.08.008</mixed-citation></ref><ref id="scirp.28141-ref29"><label>29</label><mixed-citation publication-type="other" xlink:type="simple">Carraro Group.  
www.santerno.com/company/company-profile/</mixed-citation></ref></ref-list></back></article>