<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">ENG</journal-id><journal-title-group><journal-title>Engineering</journal-title></journal-title-group><issn pub-type="epub">1947-3931</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/eng.2013.51001</article-id><article-id pub-id-type="publisher-id">ENG-26392</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Aging Effect on Characteristics of Oil Impregnated Insulation Paper for Power Transformers
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>oai</surname><given-names>S. Nasrat</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Nesrine</surname><given-names>Kassem</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Nadia</surname><given-names>Shukry</given-names></name></contrib></contrib-group><aff id="aff2"><addr-line>Cellulose and Paper Department, National Research Center, Cairo, Egypt</addr-line></aff><aff id="aff1"><addr-line>Electrical Engineering Department, Faculty of Engineering, South Valley University, Aswan, Egypt</addr-line></aff><pub-date pub-type="epub"><day>24</day><month>01</month><year>2013</year></pub-date><volume>05</volume><issue>01</issue><fpage>1</fpage><lpage>7</lpage><history><date date-type="received"><day>September</day>	<month>11,</month>	<year>2012</year></date><date date-type="rev-recd"><day>October</day>	<month>10,</month>	<year>2012</year>	</date><date date-type="accepted"><day>October</day>	<month>21,</month>	<year>2012</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
   This paper deals with experimental investigations of the electrical and physical properties of oil impregnated insulation paper for power transformers at different temperatures. The ac breakdown voltage, tensile strength and water content of insulation papers impregnated in mineral oil for different time periods were investigated. The effect of insulation paper thickness on the electrical and mechanical properties has also been studied. The results showed that the breakdown voltage and the tensile strength decreased with increasing the time of immersion of insulation paper in oil at room temperature, at 5℃ and at -12℃. Also, the thermal aging effect on the characteristic of insulation paper has been studied. It was found that high temperatures affect the breakdown voltage and the tensile strength to a great extent.
    <!--?xml:namespace prefix = o /-->
     
 
</p></abstract><kwd-group><kwd>Insulation Paper; Power Transformers; Aging; Breakdown Voltage; Tensile Strength; Water Content</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Transformers play an important role in providing a reliable and efficient electricity supply and represent the most critical equipments in electric power transmission and distribution systems [1,2]. In the early days, only a few insulation materials were known for low temperature superconducting power applications [<xref ref-type="bibr" rid="scirp.26392-ref3">3</xref>]. Paper was one of the first insulation materials used in high voltage technology [<xref ref-type="bibr" rid="scirp.26392-ref4">4</xref>]. Since winding techniques were common in the cable industry, kraft paper was used in transformers and high capacity cables. The thermal contraction of paper is low enough and elastic elongation at low temperatures is reasonable without leading to mechanical problems. Moreover, paper is very cheap compared to plastic tapes. Recently, other materials have been used in prototypes specifically for large scale high temperature superconductivity (HTS) applications such as transformers [5, 6]. However, paper can still be used in HTS transformers [<xref ref-type="bibr" rid="scirp.26392-ref7">7</xref>].</p><p>Oil filled power transformers have a composite liquidsolid insulation structure, where the oil-impregnated papers are used for both mechanical and electrical purposes. Oil impregnated papers gradually age due to thermal stress, moisture and acidity; and their degradation affects the lifetime of the power transformers [8,9].</p><p>In this study, the aim is to examine how aging affects the mechanical, electrical and physical characteristics of oil impregnated papers. The study presents experimental results of oil impregnated paper breakdown strength under ac (50 Hz) voltage. Also, physical and mechanical measurements have been investigated namely: moisture content and tensile strength.</p></sec><sec id="s2"><title>2. Experimental</title><p>Mineral oil impregnated insulation kraft papers with various thicknesses (0.2, 0.3 and 0.4 mm) have been examined in this study. Two different sets were carried out. In the first set, samples were impregnated in mineral oil for 21, 35, 56 and 77 days at temperatures: 23˚C (Room Temp.), 5˚C and −12˚C. In the second set, the samples were subjected to thermal aging conditions by using an oven. The testing temperatures were controlled and ranged from 110˚C to 170˚C. Three different thermal aging intervals have been selected (48, 72 and 96 hours). Analysis of electrical, mechanical and physical properties of oil impregnated papers was carried out.</p><sec id="s2_1"><title>2.1. AC Breakdown Voltage of Oil Impregnated Paper</title><p>The ac breakdown voltage was measured according to ASTM D 149 using two electrodes which were 25 mm diameter brass cylinder types. A single phase auto transformer having a 5 kVA—100 kV—50 Hz, Terco type HV 9105, has been used. The oil impregnated paper was cut into circular samples with a diameter of 42 mm. For each test, five oil impregnated paper samples were testedand the average value was calculated. The voltage was applied at a rise rate of 2 kV/s until breakdown occurs.</p></sec><sec id="s2_2"><title>2.2. Water Content of Oil Impregnated Paper [<xref ref-type="bibr" rid="scirp.26392-ref10">10</xref>]</title><p>An accurate weight of the air dried sample (W<sub>2</sub>) is heated at 105˚C till constant weight and then reweighed (W<sub>1</sub>). The moisture content was calculated using the formula: % Water content = (W<sub>2</sub> – W<sub>1</sub>) &#215; 100/W<sub>1</sub>.</p></sec><sec id="s2_3"><title>2.3. Tensile Strength of Oil Impregnated Paper</title><p>It is estimated according to the German Standard Method [<xref ref-type="bibr" rid="scirp.26392-ref11">11</xref>] on LLOYD LR 10K instrument. A paper strip of 15 mm wide and 15 cm length was clamped at each end between the two jaws, and an increasing load was applied causing the clamps to move apart until the strip breaks at a certain force. Tensile Strength = Force (N)/Paper thickness &#215; width (mm<sup>2</sup>).</p></sec></sec><sec id="s3"><title>3. Results and Discussion</title><p>In the last decades, dielectric testing techniques are being used and investigated as potential tools for condition assessment of oil-paper insulation. From fields and laboratory investigations, these techniques were found to be highly operating conditions (water content, aging, temperature, etc.) dependent.</p><sec id="s3_1"><title>3.1. Effect of Low Temperatures on Properties of Oil Impregnated Papers</title><sec id="s3_1_1"><title>3.1.1. Effect on AC Breakdown Voltage</title><p>The experimental results of ac breakdown voltage for different thicknesses (0.2, 0.3 and 0.4 mm) of oil impregnated papers immersed at various temperatures (RT, 5˚C and −12˚C) up to 77 days are shown in Figures 1-3.</p><p><xref ref-type="fig" rid="fig1">Figure 1</xref> represents the relationship between time of immersing insulation papers (21, 35, 56 and 77 days) with thickness 0.2 mm and breakdown voltages at 23˚C (RT), 5˚C and −12˚C, respectively.</p><p>It can be seen from this figure that, as the time of immersed papers in oil increased, the breakdown voltage decreased for all tested temperatures. The value of breakdown of the blank insulation paper is 13.11 kV. The breakdown voltages were 12.14, 11.92, 11.41 and 11.26 kV for times 21, 35, 56 and 77 days, respectively, at room temperature (RT) 23˚C. By decreasing the temperature to 5˚C, the breakdown voltages were 12.31, 12.26, 11.84 and 11.69 kV for times 21, 35, 56 and 77 days, respectively; whereas at −12˚C, the breakdown voltages were 12.64, 12.51, 12.25 and 11.98 kV for the same time intervals.</p><p><xref ref-type="fig" rid="fig2">Figure 2</xref> illustrates the same relationship for impregnating paper having 0.3 mm thickness. The results took the same trend as for samples having 0.2 mm, but with</p></sec></sec></sec></body><back><ref-list><title>References</title><ref id="scirp.26392-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">R. J. Liao, J. Hao, G. Chen, Z. G. Ma and L. J. Yang, “A Comparative Study of Physicochemical, Dielectric and Thermal Properties of Pressboard Insulation Impregnated with Natural Ester and Mineral Oil,” IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 18, No. 5, 2011, pp. 1626-1637. doi:10.1109/TDEI.2011.6032833</mixed-citation></ref><ref id="scirp.26392-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">R. J. Liao, S. W. Liang, C. X. Sun, L. J. Yang and H. G. Sun, “A Comparative Study of Thermal Aging of Transformer Insulation Paper Impregnated in Natural Ester and in Mineral Oil,” European Transaction on Electrical Power, Vol. 20, No. 4, 2010, pp. 518-523.</mixed-citation></ref><ref id="scirp.26392-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">J. Gerhold and T. Tanaka, “Cryogenic Electrical Insulation of Superconducting Power Transmission Lines: Transfer of Experience Learned from Metal Superconductors to High Critical Temperature Superconductors,” Cryogenics, Vol. 38, No. 11, 1998, pp. 1173-1188.  
doi:10.1016/S0011-2275(98)00105-2</mixed-citation></ref><ref id="scirp.26392-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">T. A. Prevost and T. V. Oommen, “Cellulose Insulation in Oil-Filled Power Transformers: Part I—History and Development,” IEEE Electrical Insulation Magazine, Vol. 22, No. 1, 2006, pp. 28-35.  
doi:10.1109/MEI.2006.1618969</mixed-citation></ref><ref id="scirp.26392-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">H. G. Cheon, S. M. Baek, D. S. Kwag and S. H. Kim, “Comparison of Insulation Test of Mini-Models with Different Winding for a HTS Transformer,” IEEE Tarnsactions on Applied Superconductivity, Vol. 16, No. 2, 2006, pp. 1497-1500. doi:10.1109/TASC.2005.865224</mixed-citation></ref><ref id="scirp.26392-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">J. M. Young, S. M. Baek and S. H. Kim, “Manufacturingand Test of Model Double Pancake Coils of HTS Transformers for Cryogenic Insulation Design,” IEEE Transactions on Applied Superconductivity, Vol. 14, No. 2, 2004, pp. 928-931. doi:10.1109/TASC.2004.830321</mixed-citation></ref><ref id="scirp.26392-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">E. F. Pleva, V. Mehrotra and S. W. Schwentrly, “Conductor Requirements for High-Temperature Superconducting Utility Power Transformers,” Superconductor Science and Technology, Vol. 23, No. 1, 2010, pp. 14-25.</mixed-citation></ref><ref id="scirp.26392-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">H. Z. Ding, Z. D. Wand and P. N. Janrman, “Effect of Ageing on the Impulse Breakdown Strength of Oil Impregnated Pressboard Used in Power Transformers,” IEEE Conference on Electrical Insulation and Dielectric Phenomenon, Kansas City, 15-18 October 2006, pp. 497500.</mixed-citation></ref><ref id="scirp.26392-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">T. K. Saha and P. Purkait, “Understanding the Impacts of Moisture and Thermal Ageing on Transformer’s Insulation by Dielectric Response and Molecular Weight Measurements,” IEEE Transactions on dielectrics and Electric Insulation, Vol. 15, No. 2, 2008, pp. 568-582.</mixed-citation></ref><ref id="scirp.26392-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">K. Othmer, “Encyclopedia of Chemical Technology,” 2nd Edition, Vol. 4, Wiley, New York, 1967.</mixed-citation></ref><ref id="scirp.26392-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">The Institute of Papermaking, “Appelton,” Wisconsin Institute, Method No. 411, 1951.</mixed-citation></ref><ref id="scirp.26392-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">I. Rusznak and K. Zimmer, “Initial Processes in the Thermolysis of Cellulose Fibers,” Proceedings of Hungarian Textile Conference, Vol. 2, 1971, pp. 119-139.</mixed-citation></ref><ref id="scirp.26392-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">K. J. Rapp, C. P. McShane and J. Lukisich, “Interaction Mechanisms of Natural Ester Dielectric Fluid and Kraft Paper,” IEEE International Conference on Dielectric Liquids, Portugal, 26 June-1 July 2005, pp. 393-396.  
doi:10.1109/ICDL.2005.1490108</mixed-citation></ref><ref id="scirp.26392-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">K. Dumke, H. Borsi and E. Gockenback, “Fundamental Investigations on the Influence of Temperature and Water Content on the Electrical Behavior of Fluid Impregnated Insulating Papers,” Conference Record of the 1996 IEEE International Symposium on Electrical Insulation, Montereal, 16-19 June 1996, pp. 542-545.</mixed-citation></ref><ref id="scirp.26392-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">T. V. Oommen, “Moisture Equilibrium Charts for Transformer Insulation Drying Practice,” IEEE Transactions on Power Apparatus and Systems, Vol. 103, No. 10, 1984, pp. 3063-3067.</mixed-citation></ref><ref id="scirp.26392-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">R. Liao, C. Tang, L. Yang and S. Grzybowski, “Thermal Ageing Microscale Analysis of Power Transformer Pressboard,” IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 15, No. 5, 2008, pp. 1281-1287.</mixed-citation></ref></ref-list></back></article>