<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">OALibJ</journal-id><journal-title-group><journal-title>Open Access Library Journal</journal-title></journal-title-group><issn pub-type="epub">2333-9705</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/oalib.1111358</article-id><article-id pub-id-type="publisher-id">OALibJ-132517</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Biomedical&amp;Life Sciences</subject><subject> Business&amp;Economics</subject><subject> Chemistry&amp;Materials Science</subject><subject> Computer Science&amp;Communications</subject><subject> Earth&amp;Environmental Sciences</subject><subject> Engineering</subject><subject> Medicine&amp;Healthcare</subject><subject> Physics&amp;Mathematics</subject><subject> Social Sciences&amp;Humanities</subject></subj-group></article-categories><title-group><article-title>
 
 
  Communication of Aesthetic Data between Dentists and Laboratory Technicians in Fixed Prosthesis: A Study within Prosthetic Dental Technicians in Casablanca
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Nadia</surname><given-names>El Mesbahi</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Zineb</surname><given-names>Al Jalil</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Nassiba</surname><given-names>Gnaoui</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Laila</surname><given-names>Echajia</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Houda</surname><given-names>Moussaoui</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Department of Fixed Prosthodontics, Faculty of Dentistry, University of Hassan II, Casablanca, Morocco</addr-line></aff><pub-date pub-type="epub"><day>01</day><month>04</month><year>2024</year></pub-date><volume>11</volume><issue>04</issue><fpage>1</fpage><lpage>7</lpage><history><date date-type="received"><day>27,</day>	<month>February</month>	<year>2024</year></date><date date-type="rev-recd"><day>15,</day>	<month>April</month>	<year>2024</year>	</date><date date-type="accepted"><day>18,</day>	<month>April</month>	<year>2024</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  &lt;strong&gt;Statement of Problem:&lt;/strong&gt; Optimizing the aesthetic result of fixed prosthesis requires clear and fluid communication involving 3 partners: practitioner, patient and laboratory technician. &lt;strong&gt;Purpose:&lt;/strong&gt; The objective of this survey was to determine the use of communication of aesthetic data (shape, dimension, color, etc.) between the dentist and the laboratory technician to improve the aesthetic result &lt;strong&gt;Material and Methods:&lt;/strong&gt; A descriptive cross-sectional study was conducted among 94 dental technicians in Casablanca, Morocco. &lt;strong&gt;Results:&lt;/strong&gt; 30.09% of dentists had often reported to the laboratory technician the patient’s expectations in aesthetic restoration to produce prostheses that matched patient aesthetic requests. Dentists mainly used temporary restorative dental impressions (66.6%) and photographs with temporary prostheses (55.3%) for transferring the dimensions and shapes of crowns to the laboratory. 75.5% of dentists always used shade guide and 53.2% of dental technicians rarely made visual assessments of the patient for shade matching. &lt;strong&gt;Conclusion:&lt;/strong&gt; The communication of aesthetic data between the dentist and the laboratory technician involves efforts from both parties for the effective use of communication tools and investment in advanced digital devices for better management of patients’ aesthetic requests.
 
</p></abstract><kwd-group><kwd>Communication</kwd><kwd> Dental Technician</kwd><kwd> Fixed Dental Prosthesis</kwd><kwd> Dentist</kwd><kwd> Esthetic Data</kwd><kwd> Morocco</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Optimizing the aesthetic result of fixed prosthesis requires clear and fluid communication involving three partners: practitioner, patient and laboratory technician throughout the prosthetic chain.</p><p>The aesthetic expectations expressed by the patient are received by the dentist who has different means and techniques to transmit them to the dental technician. The increasing aesthetic requirements of patients impose a more frequent use of ceramic restorations. Dental ceramics are increasingly finding their way into today’s dentistry. [<xref ref-type="bibr" rid="scirp.132517-ref1">1</xref>] Alongside the functional data, the aesthetic data allows the laboratory technician to manufacture the prostheses according to the recommendations of the dentist [<xref ref-type="bibr" rid="scirp.132517-ref2">2</xref>] .</p><p>The quality of prosthetic care involves many aspects, including the quality of communication of aesthetic data between the dentist and the laboratory technician. Studies [<xref ref-type="bibr" rid="scirp.132517-ref3">3</xref>] - [<xref ref-type="bibr" rid="scirp.132517-ref9">9</xref>] have revealed a lack of information regarding aesthetic data (e.g. communication of shade especially for the anterior sector).</p><p>The digitalization and introduction of new technologies in the prosthesis laboratory and dental practices as well as the introduction of new dental materials allow for better patient care. The digital workflow ensures adequate precision in orienting a non-rigid connector to facilitate an aligned path to manage tilted abutments (when orthodontic treatment is not possible). It is an aesthetically pleasing alternative as well. [<xref ref-type="bibr" rid="scirp.132517-ref10">10</xref>]</p><p>The aim of this survey carried out in Morocco was to highlight the use of means of communication of aesthetic data (shape, dimension, color, etc.) between the dentist and the laboratory technician to improve the aesthetic integration of new fixed prostheses into the oral environment.</p></sec><sec id="s2"><title>2. Materials and Methods</title><p>A descriptive cross-sectional study was conducted among dental technicians in Casablanca, Morocco between 25th September 2023 and 28th November 2023.</p><p>The sample size studied was 94 dental technicians practicing in private dental laboratories in Casablanca.</p><p>Inclusion criteria</p><p>- Private dental laboratories producing fixed prostheses</p><p>- Qualified prosthetists (state or private diplomas)</p><p>- The laboratories which agreed to participate in the study</p><p>Exclusion criteria:</p><p>Prosthetists practicing illegally.</p><p>Exclusive removable prosthesis laboratory.</p><p>Data collection used an anonymous self-administered questionnaire in French. The questionnaire is a self-designed one and includes specific aesthetic data on fixed prostheses such as crown shapes and dimensions, methods of communicating color as shade guide and electronic shade taking devices, diagnostic wax, and tooth preparation guide.</p><p>The questionnaire was distributed directly at the dental laboratory office. The questions were pilot-tested in 6 private dental laboratories by laboratory technicians.</p><p>The laboratories were selected randomly according to the indications on Google Maps or on some websites (T&#233;l&#233;contact, PagesMaroc, Maroc Annuaire) as well as on the indications of some dentists or dental technicians.</p></sec><sec id="s3"><title>3. Results</title><p>The sample of dental technicians in our study was composed of 62.8% men and 37.2% of them were aged between 35 and 49 years old.</p><p>Private school graduates accounted for 55.3% and 38.3% had more than 15 years experience.</p><p>The results of this study can be found in the following tables (Tables 1-3).</p></sec><sec id="s4"><title>4. Discussion</title><p>The lack of information on aesthetic data can be justified by incomplete training of future dentists or that some practitioners consider some information to be more important than others [<xref ref-type="bibr" rid="scirp.132517-ref3">3</xref>] .</p><p>Dentists and dental technicians take during their initial training courses on data communication necessary to carry out prosthetic work.</p><p>Regarding the guide for manufacturing the definitive prosthesis, 53% of the laboratory technicians stated that dentists often provided them with a guide for making the definitive prosthesis (diagnostic wax, tooth preparation guide, dental temporary prosthesis impression) (<xref ref-type="table" rid="table3">Table 3</xref>).</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Communication of crown shapes and dimensions</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Variable</th><th align="center" valign="middle" >%</th></tr></thead><tr><td align="center" valign="middle" >Dental impressions of temporary restorations</td><td align="center" valign="middle" >66.0</td></tr><tr><td align="center" valign="middle" >Diagnostic waxes</td><td align="center" valign="middle" >47.9</td></tr><tr><td align="center" valign="middle" >Written instructions</td><td align="center" valign="middle" >24.5</td></tr><tr><td align="center" valign="middle" >Drawing</td><td align="center" valign="middle" >12.8</td></tr><tr><td align="center" valign="middle" >Photographs with the temporary prosthesis</td><td align="center" valign="middle" >55.3</td></tr><tr><td align="center" valign="middle" >Old photographies of the patient before edentulism</td><td align="center" valign="middle" >54.3</td></tr><tr><td align="center" valign="middle" >Other ways</td><td align="center" valign="middle" >3.2</td></tr></tbody></table></table-wrap><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Methods of communicating color</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Variable</th><th align="center" valign="middle" >%</th></tr></thead><tr><td align="center" valign="middle" >Visual assessment methods (shade guide…)</td><td align="center" valign="middle" >58.5</td></tr><tr><td align="center" valign="middle" >Electronic shade taking devices</td><td align="center" valign="middle" >8.5</td></tr><tr><td align="center" valign="middle" >Both methods</td><td align="center" valign="middle" >33</td></tr></tbody></table></table-wrap><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Communication of other aesthetic data</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Variable</th><th align="center" valign="middle" >%</th></tr></thead><tr><td align="center" valign="middle" >Communication of a guide to manufacture the definitive prosthesis (diagnostic wax, tooth preparation guide, etc.)</td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >Always</td><td align="center" valign="middle" >21.3</td></tr><tr><td align="center" valign="middle" >Often</td><td align="center" valign="middle" >53.2</td></tr><tr><td align="center" valign="middle" >Rarely</td><td align="center" valign="middle" >20.2</td></tr><tr><td align="center" valign="middle" >Never</td><td align="center" valign="middle" >5.3</td></tr><tr><td align="center" valign="middle" >Indication by dentists of the shade:</td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >Using shade guide:</td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >Always</td><td align="center" valign="middle" >75.5</td></tr><tr><td align="center" valign="middle" >Often</td><td align="center" valign="middle" >19.1</td></tr><tr><td align="center" valign="middle" >Rarely</td><td align="center" valign="middle" >4.3</td></tr><tr><td align="center" valign="middle" >Never</td><td align="center" valign="middle" >1.1</td></tr><tr><td align="center" valign="middle" >Using other tooth characteristics (texture, shine, translucency):</td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >Always</td><td align="center" valign="middle" >13.8</td></tr><tr><td align="center" valign="middle" >Often</td><td align="center" valign="middle" >54.3</td></tr><tr><td align="center" valign="middle" >Rarely</td><td align="center" valign="middle" >25.5</td></tr><tr><td align="center" valign="middle" >Never</td><td align="center" valign="middle" >6.4</td></tr><tr><td align="center" valign="middle" >Visual assessment of the patient by the dental technician for shade matching:</td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >Always</td><td align="center" valign="middle" >3.2</td></tr><tr><td align="center" valign="middle" >Often</td><td align="center" valign="middle" >21.3</td></tr><tr><td align="center" valign="middle" >Rarely</td><td align="center" valign="middle" >53.2</td></tr><tr><td align="center" valign="middle" >Never</td><td align="center" valign="middle" >22.3</td></tr></tbody></table></table-wrap><p>However, a study conducted in Ireland showed that laboratory technicians did not receive a guide in 68% of cases [<xref ref-type="bibr" rid="scirp.132517-ref5">5</xref>] .</p><p>The creation of temporary restorations follows the same mechanical, biological, or aesthetic principles as the definitive prosthesis. It is an essential communication tool in the prosthetic project allowing the patient to visualize and appreciate their future prosthesis and to inform the clinician about possible modifications which will be transferred to the laboratory so that the final prosthesis is the exact replica of the temporary prosthesis differing only in the material used.</p><sec id="s4_1"><title>4.1. Communication Crown Shape and Dimensions</title><p>To transfer the shapes and dimensions of the crowns to the laboratory, the dentists mainly used the impressions of the provisional restorations 66% followed by photographies with the dental provisional prosthesis in the mouth (55%) then the old photographies before edentulism or dental disrepair (54.3%). (<xref ref-type="table" rid="table1">Table 1</xref>)</p><p>In the United Kingdom, written instructions were the main means of transferring crown dimensions to the laboratory (30%) followed by digital photography (24%) then drawings (15%). [<xref ref-type="bibr" rid="scirp.132517-ref5">5</xref>]</p></sec><sec id="s4_2"><title>4.2. Color Communication</title><p>To communicate the color to the laboratory, dentists mainly used subjective visual assessment methods (shade guide) in 58.5% of cases and objective instrumental methods (digital reports) in 8.5% of cases. Both methods are used in 33% of cases. (<xref ref-type="table" rid="table2">Table 2</xref>) These results reflect the efforts of dental practices and prosthesis laboratories to evolve their practice by investing in technology and digital tools for better color communication of fixed prosthesis.</p></sec><sec id="s4_3"><title>4.3. Communication of Other Aesthetic Data</title><sec id="s4_3_1"><title>4.3.1. Additional Data When Choosing the Shade</title><p>- Using shade guide</p><p>Dentists always indicated the shade guide used according to 75.5% of dental technicians (<xref ref-type="table" rid="table3">Table 3</xref>). Likewise, more than half of the laboratories studied in Saudi Arabia confirmed that the shade guide was indicated by more than 75% of dentists [<xref ref-type="bibr" rid="scirp.132517-ref11">11</xref>] .</p><p>However, a study in the United States showed that 84% of the forms received did not specify the shade guide used [<xref ref-type="bibr" rid="scirp.132517-ref3">3</xref>] .</p><p>In the United Kingdom, 81% of laboratories had rarely received photographs of patients with the shade guide used [<xref ref-type="bibr" rid="scirp.132517-ref4">4</xref>] .</p></sec><sec id="s4_3_2"><title>4.3.2. Other Tooth Characteristics</title><p>When communicating the color, other characteristics of the tooth (texture, shine, translucency) were often provided to the laboratory technician at a rate of 54.3%. (<xref ref-type="table" rid="table3">Table 3</xref>)</p><p>Indeed, the reproduction of the natural tooth is one of the most complex steps to accomplish and requires the skill and expertise of the ceramist to refer to all the individual characteristics linked to the patient.</p></sec><sec id="s4_3_3"><title>4.3.3. Visual Assessment of the Patient by the Dental Technician for Shade Matching</title><p>In our study, 53.3% of dental technicians rarely saw patients in the laboratory for shade matching. (<xref ref-type="table" rid="table3">Table 3</xref>)</p><p>A study in the United Kingdom reported that 9% of laboratory technicians took the patient’s advice on shade selection. [<xref ref-type="bibr" rid="scirp.132517-ref12">12</xref>]</p><p>According to a study carried out in Dakar, 3.3% of dentists delegated shade taking to the laboratory technician. However, dental laboratories rarely had the means to choose the shade in the patient’s mouth in minimal hygiene conditions (hand disinfection, gloves, masks) [<xref ref-type="bibr" rid="scirp.132517-ref13">13</xref>] .</p><p>One of the limitations of our research is of questionnaire did not address the type of material used for the fixed prosthesis (porcelain-fused to metal prosthesis or all-ceramic) and did not specify whether the choice of material and type of ceramic was made by the dentist or the dental technician. The pontic design of the prosthesis is necessary to take in account for an aesthetic result. [<xref ref-type="bibr" rid="scirp.132517-ref8">8</xref>]</p><p>Also, the study took place in Casablanca which is the economic capital of Morocco. Indeed, the demographic characteristics of the sample are specific to Casablanca and therefore do not reflect the situation in Morocco.</p></sec></sec></sec><sec id="s5"><title>5. Conclusion</title><p>The communication of aesthetic data between the dentist and the laboratory technician involves efforts of both partners for the effective use of communication devices and for the investment in advanced digital tools. The final objective is better management of the patient’s aesthetic requests.</p></sec><sec id="s6"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest.</p></sec><sec id="s7"><title>Cite this paper</title><p>Mesbahi, N.E., Jalil, Z.A., Gnaoui, N., Echajia, L. and Moussaoui, H. (2024) Communication of Aesthetic Data between Dentists and Laboratory Technicians in Fixed Prosthesis: A Study within Prosthetic Dental Technicians in Casablanca. Open Access Library Journal, 11: e11358. http://doi.org/10.4236/oalib.1111358</p></sec></body><back><ref-list><title>References</title><ref id="scirp.132517-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Saravi, B., Vollmer, A., Hartmann, M., Lang, G., Kohal, R.J., Boeker, M. and Patzelt, S.B.M. (2021) Clinical Performance of CAD/CAM All-Ceramic Tooth-Supported Fixed Dental Prostheses: A Systematic Review and Meta-Analysis. Materials (Basel), 14, Article 2672. https://doi.org/10.3390/ma14102672</mixed-citation></ref><ref id="scirp.132517-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Afsharzand, Z., Rashedi, B. and Petropoulos, V.C. (2006) Communication between the Dental Laboratory Technician and Dentist: Work Authorization for Fixed Partial Dentures. Journal of Prosthodontics, 15, 123-128. https://doi.org/10.1111/j.1532-849X.2006.00086.x</mixed-citation></ref><ref id="scirp.132517-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Berry, J., Nesbit, M., Saberi, S. and Petridis, H. (2014) Communication Methods and Production Techniques in Fixed Prosthesis Fabrication: A UK Based Survey. Part 1: Communication Methods. British Dental Journal, 217, E12. https://doi.org/10.1038/sj.bdj.2014.643</mixed-citation></ref><ref id="scirp.132517-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Lynch, C.D. and Allen, P.F. (2005) Quality of Communication between Dental Practitioners and Dental Technicians for Fixed Prosthodontics in Ireland. Journal of Oral Rehabilitation, 32, 901-905. https://doi.org/10.1111/j.1365-2842.2005.01544.x</mixed-citation></ref><ref id="scirp.132517-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Hatzikyriakos, A., Petridis, H.P., Tsiggos, N. and Sakelariou, S. (2006) Considerations for Services from Dental Technicians in Fabrication of Fixed Prostheses: A Survey of Commercial Dental Laboratories in Thessaloniki, Greece. Journal of Prosthetic Dentistry, 96, 362-366. https://doi.org/10.1016/j.prosdent.2006.08.017</mixed-citation></ref><ref id="scirp.132517-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Bu&amp;#537;tiuc1, S.G., Caraiane, A., Sin, E.C., Murineanu, R.M. and Raftu, G. (2020) Particularities of the Dentist-Dental Technician Communication in the Design and Manufacture of Fixed Partial Prostheses. Romanian Journal of Oral Rehabilitation, 12, 47-50.</mixed-citation></ref><ref id="scirp.132517-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Al-AlSheikh, H.M. (2012) Quality of Communication between Dentists and Dental Technicians for Fixed and Removable Prosthodontics. King Saud University Journal of Dental Sciences, 3, 55-60. https://doi.org/10.1016/j.ksujds.2012.07.002</mixed-citation></ref><ref id="scirp.132517-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Shetty, S., Pawashe, K., Sanyal, P. and Sushma, R. (2020) A Study to Assess Communication Hindrances by the Means of Work Authorization for Fixed Dental Prosthesis: A Survey. The Journal of Indian Prosthodontic Society, 20, 208-213. https://doi.org/10.4103/jips.jips_475_19</mixed-citation></ref><ref id="scirp.132517-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Tulbah, H., AlHamdan, E., AlQahtani, A., AlShahrani, A. and AlShaye, M. (2017) Quality of Communication between Dentists and Dental Laboratory Technicians for Fixed Prosthodontics in Riyadh, Saudi Arabia. The Saudi Dental Journal, 29, 111-116. https://doi.org/10.1016/j.sdentj.2017.05.002</mixed-citation></ref><ref id="scirp.132517-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Mukhopadhyay, P., Khalikar, A., Wankhade, S. and Deogade, S. (2021) Managing Tilted Molar Abutment Using a Digitally Fabricated Split-Pontic Fixed Dental Prosthesis—A Case Report. Open Journal of Stomatology, 11, 311-316. https://doi.org/10.4236/ojst.2021.118027</mixed-citation></ref><ref id="scirp.132517-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Blackwell, E., Nesbit, M. and Petridis, H. (2017) Survey on the Use of CAD-CAM Technology by UK and Irish Dental Technicians. British Dental Journal, 222, 689-693. https://doi.org/10.1038/sj.bdj.2017.407</mixed-citation></ref><ref id="scirp.132517-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Aquilino, S.A. and Taylor, T.D. (1984) Prosthodontic Laboratoty and Curriculum Survey. Part III: Fixed Prosthodontic Laboratory Survey. The Journal of Prosthetic Dentistry, 52, 879-885 https://doi.org/10.1016/S0022-3913(84)80025-6</mixed-citation></ref><ref id="scirp.132517-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Gueye, M., Thioune, N., Didia, E.L. and Mbodj, E.B. (2014) Collaboration entre le cabinet dentaire et le laboratoire de prothèse: Enquête auprès des chirurgiens dentistes de Dakar. Rev Col Odonto-Stomatol Afr Chir Maxillo-fac, 21, 19-23</mixed-citation></ref></ref-list></back></article>