<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">ENG</journal-id><journal-title-group><journal-title>Engineering</journal-title></journal-title-group><issn pub-type="epub">1947-3931</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/eng.2022.141006</article-id><article-id pub-id-type="publisher-id">ENG-114817</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  CRP Binding Kinetics Enhancement Using Local Narrowing into a Bent Channel: Finite Element Analysis
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mohamed</surname><given-names>Bahri</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Imen</surname><given-names>Dermoul</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Marshet</surname><given-names>Getaye</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mohamed</surname><given-names>Amin Elaguech</given-names></name><xref ref-type="aff" rid="aff4"><sup>4</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Khouloud</surname><given-names>Djebbi</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mounir</surname><given-names>Ben Ali</given-names></name><xref ref-type="aff" rid="aff5"><sup>5</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Chaker</surname><given-names>Tlili</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Deqiang</surname><given-names>Wang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff5"><addr-line>NANOMISENE Lab, LR16CRMN01, Centre for Research on Microelectronics and Nanotechnology of Sousse, Technopole of Sousse, Sousse, Tunisia</addr-line></aff><aff id="aff2"><addr-line>Preparatory Institute for Engineering of Nabeul IPEIN, University of Carthage, Campus Universitaire, Merazka, Tunisia</addr-line></aff><aff id="aff4"><addr-line>Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing, China</addr-line></aff><aff id="aff3"><addr-line>University of Chinese Academy of Sciences, Beijing, China</addr-line></aff><aff id="aff1"><addr-line>Chongqing School, University of Chinese Academy of Sciences, Chongqing, China</addr-line></aff><pub-date pub-type="epub"><day>06</day><month>01</month><year>2022</year></pub-date><volume>14</volume><issue>01</issue><fpage>62</fpage><lpage>75</lpage><history><date date-type="received"><day>14,</day>	<month>December</month>	<year>2021</year></date><date date-type="rev-recd"><day>21,</day>	<month>January</month>	<year>2022</year>	</date><date date-type="accepted"><day>24,</day>	<month>January</month>	<year>2022</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Binding kinetics enhancement of a microfluidic biosensor into a micro-channel through the application of a supplementary mechanism has received tremendous attention because of the obtained significant enhancement factor. However, biosensor’s performance enhancement using only simple channel engineering is still rarely realized. Herein, we present a novel design of a complex reactive protein (CRP) biosensor into a U-shaped channel with a sensitive membrane located in the middle of the bent zone. Various critical factors affecting the equilibrium binding time are numerically investigated. The turn geometry is then optimized when the arc length along the inner and outer radii is almost the same, which leads to locally minimizing the channel height overhead the reaction surface and improves the analyte transport towards the sensing area. The numerical studies reveal that applying a local narrowing above the reaction surface can notably enhance the trapping and the surface formation of complex antibody-antigen, thus upgrading the biosensor performance. This work puts a significant advance towards microfluidic channel engineering and the exploration of micro-flow injection experimental studies.
 
</p></abstract><kwd-group><kwd>Finite Elements Method</kwd><kwd> Binding Reaction</kwd><kwd> CRP Biosensor</kwd><kwd> Microfluidic System</kwd><kwd> Microchannel Turn</kwd><kwd> Numerical Simulation</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Over the past decades, the U-shape tube has been widely used in measurement [<xref ref-type="bibr" rid="scirp.114817-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.114817-ref2">2</xref>]. One of the oldest measurements is pressure measurement, where the free end of the tube is reported with the atmosphere, and the pressure measurement is brought to another end [<xref ref-type="bibr" rid="scirp.114817-ref3">3</xref>]. Earlier studies have shown the application of a U-shaped channel to measure some physical quantities, like concentration [<xref ref-type="bibr" rid="scirp.114817-ref4">4</xref>], temperature [<xref ref-type="bibr" rid="scirp.114817-ref5">5</xref>], density [<xref ref-type="bibr" rid="scirp.114817-ref6">6</xref>], and frequency [<xref ref-type="bibr" rid="scirp.114817-ref1">1</xref>]. Nowadays, after many performance investigations, the U-shape channel has been successfully implicated into various applications, including optical fiber in chemical probes such as glucose [<xref ref-type="bibr" rid="scirp.114817-ref7">7</xref>], pH levels [<xref ref-type="bibr" rid="scirp.114817-ref8">8</xref>], ethanol [<xref ref-type="bibr" rid="scirp.114817-ref9">9</xref>], salt [<xref ref-type="bibr" rid="scirp.114817-ref10">10</xref>], and toluidine blue [<xref ref-type="bibr" rid="scirp.114817-ref11">11</xref>]. Moreover, the U-shape micro-nanochannels can generate a locally amplified electric field and significant flow disturbance, uplifting its applicability in microfluidic mixers, electro-kinetic pumps, and cell lysis processes [<xref ref-type="bibr" rid="scirp.114817-ref12">12</xref>]. Various researchers have recently demonstrated the U shape’s utility in the design of biosensors for biomarker detection. For example, Wen et al. developed a U-shaped fiber biosensor using the lamping process for MicroRNA detection [<xref ref-type="bibr" rid="scirp.114817-ref13">13</xref>]. The developed biosensor showed high selectivity and an impressive limit of detection (0.5 nM). A similar channel shape has been used for label-free detection of E. coli in which the designed biosensor exhibits a good sensitivity in solution measurements [<xref ref-type="bibr" rid="scirp.114817-ref14">14</xref>]. This shape also showed enhanced outcomes with a 10-fold improvement in the absorbance sensitivity compared to the straight probes [<xref ref-type="bibr" rid="scirp.114817-ref15">15</xref>]. It is noticeable that numerous design and fabrication aspects related to the channel characteristics have been investigated, going from the repercussion of channel configuration geometry [<xref ref-type="bibr" rid="scirp.114817-ref16">16</xref>] to the amendment of the bent region [<xref ref-type="bibr" rid="scirp.114817-ref17">17</xref>]. Accordingly, several studies have treated the turn broadening and how channels could be designed to enhance the sensor performances. Griffiths and Nilson [<xref ref-type="bibr" rid="scirp.114817-ref18">18</xref>] studied the turning effect on the growth of the band variance of neutral species induced by electroosmotic transport. In another study, Paegel et al. [<xref ref-type="bibr" rid="scirp.114817-ref19">19</xref>] put forward the local narrowing of an electrophoresis duct width upstream of a bent and then widening it again after the bent zone. The current gold standard for such measurements relies on the straight duct shape with a constant area, as detailed in our previous work [<xref ref-type="bibr" rid="scirp.114817-ref20">20</xref>]. Therefore, there is a growing interest in developing various approaches to improve mass transport in microfluidic devices that are mainly based on a supplementary enhancement mechanism. For instance, Selmi et al. [<xref ref-type="bibr" rid="scirp.114817-ref21">21</xref>] suggested a microfluidic immuno-sensor, where an additional confinement flow was joined perpendicularly to the sample flow. Thus, the rise in the makeup flow allowed the analyte to be suppressed into a thin layer bordering the biosensor. In another work, Sigurdson et al. [<xref ref-type="bibr" rid="scirp.114817-ref22">22</xref>] proposed the application of the electro-kinetically driven AC technique to ameliorate the response of the developed immuno-sensors, which greatly upgraded the antigen achievement to the immobilized ligands region. While, others have reported the use of magnetic field [<xref ref-type="bibr" rid="scirp.114817-ref23">23</xref>], obstacle above the biosensor [<xref ref-type="bibr" rid="scirp.114817-ref24">24</xref>], and electrothermal effect [<xref ref-type="bibr" rid="scirp.114817-ref25">25</xref>] to improve the target analyte achievement. Nevertheless, in some practical cases, controlling the channel geometry at a small scale via a supplementary enhancement system might be challenging and expensive due to the high fabrication costs.</p><p>Recently, there exists a great deal of exploring the pivotal role of chronic inflammation in cancer development [<xref ref-type="bibr" rid="scirp.114817-ref26">26</xref>]. The C-reactive protein (CRP) was considered as one of the most commonly studied chronic inflammation biomarkers [<xref ref-type="bibr" rid="scirp.114817-ref27">27</xref>], and multiple prospective studies revealed that patients with diverse types of cancer including lung cancer have moderately elevated circulating levels of CRP [<xref ref-type="bibr" rid="scirp.114817-ref28">28</xref>]. Therefore, there is an ultimate need for the development of a rapid and highly sensitive biosensor for CRP detection, where the existence of an enhancement system can put a significant stepping stone for upgrading the biosensor performance.</p><p>The above viewpoints have inspired the present work, where we employed the finite element method to simulate the CRP binding reaction through a U-shaped microchannel. Various crucial factors that affect the equilibrium binding time are discussed, such as the inlet flow velocity, the bulk analyte concentration, and the microchannel’s equivalent height. An enhancement factor of about 1.20 was obtained using simple local narrowing of the microchannel above the biosensor. We find that upgrading the binding reaction without any supplementary enhancement mechanism via only simple channel engineering could have a significant role to fabricate microfluidic gadgets.</p></sec><sec id="s2"><title>2. Theoretical Model</title><p>The recognition between an analyte carried by a fluid with a concentration [A] (CRP), and immobilized ligands [B] (anti-CRP), is occurring at a 2D membrane with reaction kinetics leading to form the complex CRP/anti-CRP. The surface reaction can be depicted in a two-step process as follows:</p><p>1) [ A ] Bulk ⇄ [ A ] Surface <sub> </sub></p><p>2) [ A ] Surface + [ B ] ⇄ K off K on [ A B ]</p><p>In this case, [A]<sub>Bulk</sub> represents the analyte’s bulk concentration, and [A]<sub>Surface</sub> is the reaction surface’s analyte concentration. [B] refers to the surface-immobilized ligand concentration, and [AB] represents the complex analyte-ligand surface concentration. K<sub>on</sub> and K<sub>off</sub> are the association and dissociation rate constant, respectively. The first process (1) is called mass-transport, controlled by diffusion mechanism and governing the analyte transport from the bulk toward the reaction surface. The second process (2) is the binding reaction; a chemical reaction that describes the surface complex’s formation. In this work, we assume that the developed immunoassay mixes the concentration of biological analyte human CRP in a neutral buffer solution that can be the phosphate buffer saline, which presents physical characteristics comparable to the water [<xref ref-type="bibr" rid="scirp.114817-ref29">29</xref>]. Hence, was utilized as a carrier fluid.</p><p>1) Microchip design</p><p>The flow is static under the condition of a non-slip flow for the wall condition, where the analyte is transported toward the chemical reaction surface by convection and diffusion. This whole phenomenon involves an expansion of a diffusion boundary layer, which depends on the ratio of the surface reaction rate, and the bordering biosensor’s flow velocity. The simulated device properties are shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>.</p><p>The channel width is assumed to be 100 &#181;m. The straight section’s length (L) of the microchannel is 1 mm, and the outer radius (r<sub>0</sub> for the curved microchannel is 150 &#181;m. The fluid containing biological analyte (CRP) concentrations is injected at x = 1000 &#181;m, flows from the left up to the left down boundaries along the x-axis, crosses the turn, and retraces the path with flowing along the x-axis again to attain the outlet boundary. For all the simulations, the biosensor length is sustained correlative to the reaction surface which is 100 &#181;m. The biosensor is centered in the middle of the turn at 140 &#181;m, and 0 &#181;m at the x-axis and y-axis, respectively. The problem is then unriddled based on the Fick second law coupled with the Navier-Stokes equations, and the first order Langmuir adsorption model for the reaction rate between the analyte and the ligand was employed.</p><p>2) Mathematical formulations</p><p>The developed approach is based on the finite element method [<xref ref-type="bibr" rid="scirp.114817-ref30">30</xref>] for a microfluidic biosensor in a two-dimensional microchannel, and thus, the surface concentration of complex analyte-ligand versus time was calculated. The mathematical model was used to simulate the binding reaction between a solution A (CRP) transported by a fluid to reach a sensitive boundary where a ligand B of (anti-CRP) is immobilized. A finite element platform (Comsol Multiphysics, COMSOL, Sweden v5.2a) [<xref ref-type="bibr" rid="scirp.114817-ref31">31</xref>] was utilized to compute a 2D simulation of momentum along with mass transport into the micro-scaled channel and overhead the biosensor surface.</p><p>a) Navies-Stokes equations</p><p>In this work, the fluid is assumed to be Newtonian and incompressible, with a laminar flow, isotherm, and steady-state. Hence the governing equations with dimensionless quantities can be described as the following equations [<xref ref-type="bibr" rid="scirp.114817-ref32">32</xref>] [<xref ref-type="bibr" rid="scirp.114817-ref33">33</xref>];</p><p>∂ u ∂ x + ∂ v ∂ y = 0 (1)</p><p>ρ ∂ u ∂ t + ρ ( u ∂ u ∂ x + v ∂ u ∂ y ) − η ∇ 2 u + ∂ p ∂ x = 0 (2)</p><p>ρ ∂ v ∂ t + ρ ( u ∂ v ∂ x + v ∂ v ∂ y ) − η ∇ 2 v + ∂ p ∂ y = 0 (3)</p><p>where u and v are the x and y velocity components, respectively, ρ and η are the fluid’s density and dynamic viscosity, respectively, and p is the pressure. Both ρ and η are constant and independent from the temperature or concentration. The flow field module is modeled via the Navier-Stokes equations associated with the initial and boundary conditions.</p><p>b) Fick second law equation</p><p>The analyte transport to land on the sensitive surface is depicted by the following equation [<xref ref-type="bibr" rid="scirp.114817-ref34">34</xref>]:</p><p>∂ [ A ] ∂ t + u ∂ [ A ] ∂ x + v ∂ [ A ] ∂ y = D ( ∂ 2 [ A ] ∂ x 2 + ∂ 2 [ A ] ∂ y 2 ) (4)</p><p>where D is the analyte diffusion coefficient and for human CRP its value is equal to 2.175 &#215; 10<sup>−11</sup> m<sup>2</sup>/s.</p><p>c) Binding reaction</p><p>The chemical kinetics equation is simulated through the first order Langmuir adsorption model [<xref ref-type="bibr" rid="scirp.114817-ref35">35</xref>] [<xref ref-type="bibr" rid="scirp.114817-ref36">36</xref>] assuming that the complex CRP/anti-CRP [AB] was achieved on the sensitive surface is bounded without diffusion and is raised as a function of time corresponding to the reaction rate equation as the follows:</p><p>∂ [ A B ] ∂ t = K on [ A ] Surface { [ B 0 ] − [ A B ] } − K off [ A B ] (5)</p><p>where [A]<sub>Surface</sub> is the reaction surface analyte concentration, and [B<sub>0</sub>] is the immobilized ligand’s concentration which is assumed to be 1.4 &#215; 10<sup>−8</sup> mol/m<sup>2</sup>. K<sub>on</sub> and K<sub>off</sub> are the association and dissociation rate constants, respectively, corresponding to 1 &#215; 10<sup>4</sup> m<sup>3</sup>/mol∙s and 2.6 &#215; 10<sup>−2</sup> s<sup>−1</sup> for the CRP-anti-CRP binding interactions.</p><p>3) Numerical method and validation</p><p>In this theoretical study, the stationary simulation was performed with constant pressure boundary conditions by setting 0 Pa at the channel’s inlet and outlet. Additionally, a non-slip boundary condition was applied at the microchannel’s walls. The flow is laminar with a low Reynolds number [<xref ref-type="bibr" rid="scirp.114817-ref37">37</xref>], isotherm, and steady. Whereas the fluid is initially supposed to be at rest. The initial concentrations of the complex CRP/antiCRP [AB] and the bulk analyte concentration [A] were set zero as initial conditions. In our case, the fluid was initially at rest, and the parabolic profile’s average velocity was fixed at u = 10<sup>4</sup> m/s at the inlet boundary. The fluid parameters were supposed to be similar to the room temperature distilled water parameters (η = 1 mPa∙s, ρ = 1000 kg∙m<sup>−3</sup>). And the [B<sub>0</sub>] was fixed at 1.4 &#215; 10<sup>−8</sup> mol/m<sup>2</sup>, and K<sub>on</sub> and K<sub>off</sub> were set at 1 &#215; 10<sup>4</sup> m<sup>3</sup>/mol∙s and 2.6 &#215; 10<sup>−2</sup> s<sup>−1</sup>, respectively [<xref ref-type="bibr" rid="scirp.114817-ref20">20</xref>] [<xref ref-type="bibr" rid="scirp.114817-ref32">32</xref>].</p><p>The previously mentioned governing equations’ solution using initial and boundary conditions applied in 2D has no analytical solution. Thus, Comsol software simulation offers the possibility to couple the laminar flow with the transport of diluted species physics module. To discretize the designed 2D domains, an unstructured triangular mesh was utilized; somehow, the neighboring area of the biosensor is more fine-grained than that of the bulk for a higher resolution [<xref ref-type="bibr" rid="scirp.114817-ref38">38</xref>], as displayed in <xref ref-type="fig" rid="fig2">Figure 2</xref>(a). Several mesh grids were applied to ensure the convergence and mesh independent of the numerical outcomes, as presented in <xref ref-type="fig" rid="fig2">Figure 2</xref>(b). Hence, no significant variation was found between the curves computed with 83070 and 56966 grids elements. Similar numerical convergence was found and explained as well [<xref ref-type="bibr" rid="scirp.114817-ref38">38</xref>]. Unless specified, all the computational studies were achieved with a total element number of 56,966.</p><p>4) Binding kinetics of protein CRP and inlet flow velocity</p><p>The surface complex concentration for the CRP versus different analyte concentrations, namely, 64, 12, 6.4, 1.2, and 0.64 nM, is depicted in <xref ref-type="fig" rid="fig3">Figure 3</xref>(a). The bulk analyte concentration rise leads to an increase of the trapped biomolecule concentration on the biosensor surface. The theoretical explanation behind the increase of the complex concentration [AB] versus the analyte concentration [A] is related to the Equation (7). Equation (7) can be obtained from Equation (5)</p><p>through the equilibrium association state ( ∂ [ A B ] ∂ t = 0 ) as shown in Equation (6) [<xref ref-type="bibr" rid="scirp.114817-ref32">32</xref>]</p><p>K on [ A ] Surface { [ B 0 ] − [ A B ] } − K off [ A B ] = 0 (6)</p><p>[ A B ] = K off [ A B ] B 0 K on [ A ] + K off = [ A ] B 0 [ A ] + K D (7)</p><p>where K D = K off K on is the dissociation equilibrium constant. Additionally, the</p><p>rise of the inlet flow velocity is effectively downsizing the diffusion boundary thickness, which notably enhances the rates of association and dissociation phases of the CRP/antiCRP binding reaction, as shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>(b). The same explanation has been well detailed by Yang and co-workers, who pointed out the different parameters affecting the CRP binding reaction through a straight microfluidic duct [<xref ref-type="bibr" rid="scirp.114817-ref32">32</xref>]. The same numerical results are here used as a reference to validate the obtained data, which is matched well in terms of trapped complex concentration on the biosensor surface. Hence, association and dissociation rate, and time dependence are here unmatched due to the channel size and geometry difference.</p></sec><sec id="s3"><title>3. Results and Discussion</title><p>1) Diffusion boundary layer</p><p>Due to its small diffusion coefficient, the protein as a large molecule is limited by the binding reaction’s mass transport coefficient of the complex antigen-antibody structure [<xref ref-type="bibr" rid="scirp.114817-ref39">39</xref>]. Thus, this mass transport coefficient (K<sub>m</sub>) is defined by the flow velocity and the diffusion coefficient. K<sub>m</sub> can be defined from the Levich expression [<xref ref-type="bibr" rid="scirp.114817-ref40">40</xref>] as follows:</p><p>K m = 0.98 ∗ D 2 3 ( U L ∗ H ) 1 3 (8)</p><p>where D is the diffusion coefficient, and U is the inlet flow average, L and H are the position of the sensitive surface and the channel height, respectively. Consequently, the diffusion boundary layer can be given as a function of the diffusion and the mass transport coefficients as follows [<xref ref-type="bibr" rid="scirp.114817-ref41">41</xref>]:</p><p>d d i f f = D K m</p><p>The diffusion boundary layer development will go up along the reaction boundary in the same flow direction. Thus, systematic mass transport is characterized by a lower thickness of the diffusion layer. <xref ref-type="fig" rid="fig4">Figure 4</xref> shows the development of the diffusion boundary layer on the biosensor surface after different computational times. Accordingly, mass transport is occurring alongside the reaction surface following the same fluid path. Besides, during the association phase, the consumption of [A]<sub>Surface</sub> is briefer on the biosensor surface when compared with its consumption in the bulk. Consequently, a thin diffusion layer of the analyte above the biosensor is constructed explained by local consumption of the analyte concentration. Contrary to the association phase, a relatively higher analyte concentration covering the reaction surface than that of the bulk</p><p>can be clearly noticed during the dissociation phase, where no more analyte flows in the system [<xref ref-type="bibr" rid="scirp.114817-ref32">32</xref>].</p><p>2) Local narrowing method (reduction of the microchannel equivalent height)</p><p>As mentioned in the previous section, the relation combining the reaction channel height and the coefficient mass transport is resumed in the Levich Equation (8). Whence, decreasing the channel height (H) can notably downscale the diffusion coefficient (D) and promotes the mass transport coefficient (K<sub>m</sub>). In this subsection, the channel height overhead the reaction surface is varied depending on (R<sub>0</sub>) and (R<sub>1</sub>) as two specific narrowing dimensions presented in <xref ref-type="fig" rid="fig5">Figure 5</xref>(a) and detailed in <xref ref-type="table" rid="table1">Table 1</xref>.</p><p><xref ref-type="fig" rid="fig5">Figure 5</xref>(b) displays the complex CRP concentration evolution versus time for different channel heights (R<sub>1</sub>). Here, it is worth mentioning that every computation of different microchannel heights was achieved at a constant bulk analyte concentration and an average flow velocity of 6.4 nM and 100 &#181;m/s, respectively. <xref ref-type="table" rid="table1">Table 1</xref> compiles the binding reaction initial slope of the association and dissociation phases. Note that by minimizing the channel height that covers the sensitive membrane from a drop case (100 &#181;m) to 40 &#181;m, the binding reaction can be greatly enhanced, recording larger initial slopes from 1.76 &#215; 10<sup>−11</sup> to 2.1 &#215; 10<sup>−11</sup> for the association phase and from −5.67 &#215; 10<sup>−12</sup> to −6.81 &#215; 10<sup>−12</sup> for the dissociation phase. Such local narrowing leads to enhancement factors of 1.19 and 1.20 for the association and the dissociation phase, respectively. A larger slope of the CRP binding was found at a lower equivalent height. This can be</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Initial slope and enhancement factors of CRP binding reaction association and dissociation phases for different narrowing dimensions (R<sub>0</sub>) and (R<sub>1</sub>)</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Geometry</th><th align="center" valign="middle" >R<sub>1</sub> (&#181;m)</th><th align="center" valign="middle" >R<sub>0</sub> (&#181;m)</th><th align="center" valign="middle" >Initial slope (association)</th><th align="center" valign="middle" >Initial slope (dissociation)</th><th align="center" valign="middle" >Enhancement factor* (association)</th><th align="center" valign="middle" >Enhancement factor* (dissociation)</th></tr></thead><tr><td align="center" valign="middle" >Original geometry</td><td align="center" valign="middle" >100</td><td align="center" valign="middle" >50</td><td align="center" valign="middle" >1.76 &#215; 10<sup>−11</sup></td><td align="center" valign="middle" >−5.67 &#215; 10<sup>−12</sup></td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >-</td></tr><tr><td align="center" valign="middle" >Optimized geometry 1</td><td align="center" valign="middle" >70</td><td align="center" valign="middle" >8</td><td align="center" valign="middle" >1.86 &#215; 10<sup>−11</sup></td><td align="center" valign="middle" >−6.30 &#215; 10<sup>−12</sup></td><td align="center" valign="middle" >1.05</td><td align="center" valign="middle" >1.11</td></tr><tr><td align="center" valign="middle" >Optimized geometry 2</td><td align="center" valign="middle" >60</td><td align="center" valign="middle" >90</td><td align="center" valign="middle" >1.97 &#215; 10<sup>−11</sup></td><td align="center" valign="middle" >−6.50 &#215; 10<sup>−12</sup></td><td align="center" valign="middle" >1.12</td><td align="center" valign="middle" >1.15</td></tr><tr><td align="center" valign="middle" >Optimized geometry 3</td><td align="center" valign="middle" >40</td><td align="center" valign="middle" >110</td><td align="center" valign="middle" >2.1 &#215; 10<sup>−11</sup></td><td align="center" valign="middle" >−6.81 &#215; 10<sup>−12</sup></td><td align="center" valign="middle" >1.19</td><td align="center" valign="middle" >1.20</td></tr></tbody></table></table-wrap><p>*The enhancement factors are defined as the ratio of the binding reaction slope with narrowing to that without narrowing.</p><p>explained by the faster diffusion in transporting the fluid to reach the reaction surface at lower microchannel height. Thus, the decay of the diffusion boundary layer evolution is clarified by the CRP molecules confinement into a thin layer made by the height reduction overhead the reaction surface. Accordingly, a significant enhancement of the fluid velocity near the reaction surface, improvises the target biomolecule’s consumption.</p></sec><sec id="s4"><title>4. Conclusion</title><p>In this work, we present a 2D simulation of a CRP microfluidic biosensor based on a U-shaped channel using the finite element method. Decreasing the microchannel’s equivalent height using local narrowing through simple channel engineering enhanced the CRP binding reaction’s association and dissociation rates. Importantly, the lower height of the channel and the faster average inlet velocity have led to the reduction of the diffusion boundary layer and improved the biosensor’s performance. This work can undoubtedly offer new insights for further investigation in microflow injection experimental studies.</p></sec><sec id="s5"><title>Conflicts of Interest</title><p>The authors declare that they have no conflict of interest.</p></sec><sec id="s6"><title>Funding</title><p>The authors received no direct funding for this research.</p></sec><sec id="s7"><title>Data Availability</title><p>All data generated or analyzed during this study are included in this published article.</p></sec><sec id="s8"><title>Cite this paper</title><p>Bahri, M., Dermoul, I., Getaye, M., Elaguech, M.A., Djebbi, K., Ali, M.B., Tlili, C. and Wang, D.Q. (2022) CRP Binding Kinetics Enhancement Using Local Narrowing into a Bent Channel: Finite Element Analysis. Engineering, 14, 62-75. https://doi.org/10.4236/eng.2022.141006</p></sec></body><back><ref-list><title>References</title><ref id="scirp.114817-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Younes, T.M., AlKhedher, M.A., Shgier, K.A. and Al Taweel, F. (2019) U-Shape Acoustic Liquid Densitometer. Instrumentation Mesure Metrologie, 18, 123-128. https://doi.org/10.18280/i2m.180205</mixed-citation></ref><ref id="scirp.114817-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Rechberger, A., Amsüss, R., Rossegger, S., Breidler, R. and Steiner, G. (2019) High Precision Vibration-Type Densitometers Based on Pulsed Excitation Measurements. Sensors, 19, Article No. 1627. https://doi.org/10.3390/s19071627</mixed-citation></ref><ref id="scirp.114817-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Ong, K.S., Tong, W.L. and Choong, J.K. (2016) Performance of U-Tube Solar Water Heater with Vertical and Inclined Panels. International Journal of Low-Carbon Technologies, 11, 248-253. https://doi.org/10.1093/ijlct/ctt063</mixed-citation></ref><ref id="scirp.114817-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Alsabbah, S. and Mughrabi, T. (2008) Neural Network-Based Waveguide Acoustic Gas Detector. Proceeding 5th International Symposium on Mechatronics and Its Applications (ISMA 2008), Amman, 27-29 May 2008, 1-4. https://doi.org/10.1109/ISMA.2008.4648867</mixed-citation></ref><ref id="scirp.114817-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Younes, T.M., Alia, M.A.K. and Al-Sabbah, S. (2010) Acoustic Temperature Transducer. Sensors &amp; Transducers, 119, 46-57.</mixed-citation></ref><ref id="scirp.114817-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Outcalt, S.L. and McLinden, M.O. (2007) Automated Densimeter for the Rapid Characterization of Industrial Fluids. Industrial &amp; Engineering Chemistry Research, 46, 8264-8269. https://doi.org/10.1021/ie070791e</mixed-citation></ref><ref id="scirp.114817-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Fang, Y.-L., Wang, C.-T. and Chiang, C.-C. (2016) A Small U-Shaped Bending-Induced Interference Optical Fiber Sensor for the Measurement of Glucose Solutions. Sensors, 16, Article No. 1460. https://doi.org/10.3390/s16091460</mixed-citation></ref><ref id="scirp.114817-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Raoufi, N., Surre, F., Rajarajan, M., Sun, T. and Grattan, K.T.V. (2014) Fiber Optic pH Sensor Using Optimized Layer-by-Layer Coating Approach. IEEE Sensors Journal, 14, 47-54. https://doi.org/10.1109/JSEN.2013.2280283</mixed-citation></ref><ref id="scirp.114817-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Gao, S.S., Qiu, H.W., Zhang, C., Jiang, S.Z., Li, Z., Liu, X.Y., Yue, W.W., Yang, C., Huo, Y.Y., Feng, D.J. and Li, H.S. (2016) Absorbance Response of a Graphene Oxide Coated U-Bent Optical Fiber Sensor for Aqueous Ethanol Detection. RSC Advances, 6, 15808-15815. https://doi.org/10.1039/C5RA22211G</mixed-citation></ref><ref id="scirp.114817-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Chiang, C.C. and Chao, J.C. (2013) Whispering Gallery Mode Based Optical Fiber Sensor for Measuring Concentration of Salt Solution. Journal of Nanomaterials, 2013, Article ID: 372625. https://doi.org/10.1155/2013/372625</mixed-citation></ref><ref id="scirp.114817-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Llorente, V.B., Erro, E.M., Baruzzi, A.M. and Iglesias, R.A. (2015) Optochemical Fiber Sensor for Toluidine Blue Detection in High Turbidity Media. Sensors and Actuators B: Chemical, 216, 316-320. https://doi.org/10.1016/j.snb.2015.03.085</mixed-citation></ref><ref id="scirp.114817-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Qiu, B., Gong, L., Li, Z. and Han, J. (2019) Electrokinetic Flow in the U-Shaped Micro-Nanochannels. Theoretical and Applied Mechanics Letters, 9, 36-42. https://doi.org/10.1016/j.taml.2019.01.006</mixed-citation></ref><ref id="scirp.114817-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Wen, H.Y., Huang, C.W., Le Li, Y., Chen, J.L., Yeh, Y.T. and Chiang, C.C. (2020) A Lamping U-Shaped Fiber Biosensor Detector for MicroRNA. Sensors, 20, Article No. 1509. https://doi.org/10.3390/s20051509</mixed-citation></ref><ref id="scirp.114817-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Bharadwaj, R., Sai, V.V.R., Thakare, K., Dhawangale, A., Kundu, T., Titus, S., Verma, P.K. and Mukherji, S. (2011) Evanescent Wave Absorbance Based Fiber Optic Biosensor for Label-Free Detection of E. coli at 280 nm Wavelength. Biosensors and Bioelectronics, 26, 3367-3370. https://doi.org/10.1016/j.bios.2010.12.014</mixed-citation></ref><ref id="scirp.114817-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Littlejohn, D., Lucas, D. and Han, L. (1999) Bent Silica Fiber Evanescent Absorption Sensors for Near-Infrared Spectroscopy. Applied Spectroscopy, 53, 845-849. https://doi.org/10.1366/0003702991947423</mixed-citation></ref><ref id="scirp.114817-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Radadia, A.D., Salehi-Khojin, A., Masel, R.I. and Shannon, M.A. (2010) The Effect of Microcolumn Geometry on the Performance of Micro-Gas Chromatography Columns for Chip Scale Gas Analyzers. Sensors and Actuators B: Chemical, 150, 456-464. https://doi.org/10.1016/j.snb.2010.07.002</mixed-citation></ref><ref id="scirp.114817-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Molho, J.I., Herr, A.E., Mosier, B.P., Santiago, J.G., Kenny, T.W., Brennen, R.A., Gordon, G.B. and Mohammadi, B. (2001) Optimization of Turn Geometries for Microchip Electrophoresis. Analytical Chemistry, 73, 1350-1360. https://doi.org/10.1021/ac001127+</mixed-citation></ref><ref id="scirp.114817-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Griffiths, S.K. and Nilson, R.H. (2000) Band Spreading in Two-Dimensional Microchannel Turns for Electrokinetic Species Transport. Analytical Chemistry, 72, 5473-5482. https://doi.org/10.1021/ac000595g</mixed-citation></ref><ref id="scirp.114817-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Paegel, B.M., Hutt, L.D., Simpson, P.C. and Mathies, R.A. (2000) Turn Geometry for Minimizing Band Broadening in Microfabricated Capillary Electrophoresis Channels. Analytical Chemistry, 72, 3030-3037. https://doi.org/10.1021/ac000054r</mixed-citation></ref><ref id="scirp.114817-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Bahri, M., Dermoul, I., Getaye, M., Ben Ali, M. and Abdelhamid, E. (2019) 2D Simulation of a Microfluidic Biosensor for CRP Detection into a Rotating Micro-Channel. SN Applied Sciences, 1, Article No. 1199. https://doi.org/10.1007/s42452-019-1231-8</mixed-citation></ref><ref id="scirp.114817-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Selmi, M., Echouchene, F., Gazzah, M.H. and Belmabrouk, H. (2015) Flow Confinement Enhancement of Heterogeneous Immunoassays in Microfluidics. IEEE Sensors Journal, 15, 7321-7328. https://doi.org/10.1109/JSEN.2015.2475610</mixed-citation></ref><ref id="scirp.114817-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Sigurdson, M., Wang, D. and Meinhart, C.D. (2005) Electrothermal Stirring for Heterogeneous Immunoassays. Lab on a Chip, 5, 1366-1373. https://doi.org/10.1039/b508224b</mixed-citation></ref><ref id="scirp.114817-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Munir, A., Wang, J., Li, Z. and Zhou, H.S. (2010) Numerical Analysis of a Magnetic Nanoparticle-Enhanced Microfluidic Surface-Based Bioassay. Microfluidics and Nanofluidics, 8, 641-652. https://doi.org/10.1007/s10404-009-0497-3</mixed-citation></ref><ref id="scirp.114817-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Selmi, M., Echouchene, F. and Belmabrouk, H. (2016) Analysis of Microfluidic Biosensor Efficiency Using a Cylindrical Obstacle. Sensor Letters, 14, 26-31. https://doi.org/10.1166/sl.2016.3527</mixed-citation></ref><ref id="scirp.114817-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Selmi, M., Khemiri, R., Echouchene, F. and Belmabrouk, H. (2016) Electrothermal Effect on the Immunoassay in a Microchannel of a Biosensor with Asymmetrical Interdigitated Electrodes. Applied Thermal Engineering, 105, 77-84. https://doi.org/10.1016/j.applthermaleng.2016.05.132</mixed-citation></ref><ref id="scirp.114817-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">Azad, N., Rojanasakul, Y. and Vallyathan, V. (2008) Inflammation and Lung Cancer: Roles of Reactive Oxygen/Nitrogen Species. Journal of Toxicology and Environmental Health, Part B, 11, 1-15. https://doi.org/10.1080/10937400701436460</mixed-citation></ref><ref id="scirp.114817-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">Pepys, M.B. and Hirschfield, G.M. (2003) C-Reactive Protein: A Critical Update. Journal of Clinical Investigation, 111, 1805-1812. https://doi.org/10.1172/JCI200318921</mixed-citation></ref><ref id="scirp.114817-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">Ji, M., Du, L., Ma, Z., Xie, J., Huang, Y., Wei, X., Jiang, X., Xu, J., Yin, R., Wang, Y., Dai, J., Jin, G., Xu, L., Zhu, C., Hu, Z., Ma, H., Zhu, M. and Shen, H. (2022) Circulating C-Reactive Protein Increases Lung Cancer Risk: Results from a Prospective Cohort of UK Biobank. International Journal of Cancer, 150, 47-55. https://doi.org/10.1002/ijc.33780</mixed-citation></ref><ref id="scirp.114817-ref29"><label>29</label><mixed-citation publication-type="other" xlink:type="simple">Yi, M., Zhang, H., Qi, S. and Li, Q. (2016) Determination of C-Reactive Protein Concentration in Serum Based on Chemiluminescence Analysis. 2016 8th International Conference on Measuring Technology and Mechatronics Automation (ICMTMA 2016), Macau (China), 11-12 March 2016, 214-217. https://doi.org/10.1109/ICMTMA.2016.61</mixed-citation></ref><ref id="scirp.114817-ref30"><label>30</label><mixed-citation publication-type="other" xlink:type="simple">Kuzmin, D. and Hamalainen, J. (2016) Finite Element Methods for Computational Fluid Dynamics?: A Practical Guide. Society for Industrial and Applied Mathematics, Philadelphia.</mixed-citation></ref><ref id="scirp.114817-ref31"><label>31</label><mixed-citation publication-type="other" xlink:type="simple">COMSOL Multiphysics&amp;#174; Modeling Software (n.d.). https://www.comsol.com/</mixed-citation></ref><ref id="scirp.114817-ref32"><label>32</label><mixed-citation publication-type="other" xlink:type="simple">Yang, C.K., Chang, J.S., Chao, S.D. and Wu, K.C. (2008) Effects of Diffusion Boundary Layer on Reaction Kinetics of Immunoassay in a Biosensor. Journal of Applied Physics, 103, Article ID: 084702. https://doi.org/10.1063/1.2909980</mixed-citation></ref><ref id="scirp.114817-ref33"><label>33</label><mixed-citation publication-type="other" xlink:type="simple">Thompson, J.A. and Bau, H.H. (2010) Microfluidic, Bead-Based Assay: Theory and Experiments. Journal of Chromatography B, 878, 228-236. https://doi.org/10.1016/j.jchromb.2009.08.050</mixed-citation></ref><ref id="scirp.114817-ref34"><label>34</label><mixed-citation publication-type="other" xlink:type="simple">Huang, K.R. and Chang, J.S. (2013) Three Dimensional Simulation on Binding Efficiency of Immunoassay for a Biosensor with Applying Electrothermal Effect. Heat and Mass Transfer, 49, 1647-1658. https://doi.org/10.1007/s00231-013-1214-z</mixed-citation></ref><ref id="scirp.114817-ref35"><label>35</label><mixed-citation publication-type="other" xlink:type="simple">Sadana, A. and Vo-Dinh, T. (1997) Antibody-Antigen Binding Kinetics a Model for Multivalency Antibodies for Large Antigen Systems. Biotechnology and Applied Biochemistry, 67, 1-22. https://doi.org/10.1007/BF02787837</mixed-citation></ref><ref id="scirp.114817-ref36"><label>36</label><mixed-citation publication-type="other" xlink:type="simple">Zimmermann, M., Delamarche, E., Wolf, M. and Hunziker, P. (2005) Modeling and Optimization of High-Sensitivity, Low-Volume Microfluidic-Based Surface Immunoassays. Biomedical Microdevices, 7, 99-110. https://doi.org/10.1007/s10544-005-1587-y</mixed-citation></ref><ref id="scirp.114817-ref37"><label>37</label><mixed-citation publication-type="other" xlink:type="simple">Stone, H.A., Stroock, A.D. and Ajdari, A. (2004) Engineering Flows in Small Devices: Microfluidics toward a Lab-on-a-Chip. Annual Review of Fluid Mechanics, 36, 381-411. https://doi.org/10.1146/annurev.fluid.36.050802.122124</mixed-citation></ref><ref id="scirp.114817-ref38"><label>38</label><mixed-citation publication-type="other" xlink:type="simple">Aoun, N., Echouchene, F., Diallo, A.K., Launay, J. and Belmabrouk, H. (2016) Finite-Element Simulations of the pH-ElecFET Microsensors. IEEE Sensors Journal, 16, 6519-6526. https://doi.org/10.1109/JSEN.2016.2585506</mixed-citation></ref><ref id="scirp.114817-ref39"><label>39</label><mixed-citation publication-type="other" xlink:type="simple">Chaiken, I., Rosé, S. and Karlsson, R. (1992) Analysis of Macromolecular Interactions Using Immobilized Ligands. Analytical Biochemistry, 201, 197-210. https://doi.org/10.1016/0003-2697(92)90329-6</mixed-citation></ref><ref id="scirp.114817-ref40"><label>40</label><mixed-citation publication-type="other" xlink:type="simple">Levich, V. (1962) Physicochemical Hydrodynamics. Englewood Cliffs, Prentice-Hall. http://www.worldcat.org/title/physicochemical-hydrodynamics/oclc/1378432</mixed-citation></ref><ref id="scirp.114817-ref41"><label>41</label><mixed-citation publication-type="other" xlink:type="simple">Hofmann, O., Voirin, G., Niedermann, P. and Manz, A. (2002) Three-Dimensional Microfluidic Confinement for Efficient Sample Delivery to Biosensor Surfaces. Application to Immunoassays on Planar Optical Waveguides. Analytical Chemistry, 74, 5243-5250. https://doi.org/10.1021/ac025777k</mixed-citation></ref></ref-list></back></article>