<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">ABCR</journal-id><journal-title-group><journal-title>Advances in Breast Cancer Research</journal-title></journal-title-group><issn pub-type="epub">2168-1589</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/abcr.2021.104016</article-id><article-id pub-id-type="publisher-id">ABCR-112360</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Medicine&amp;Healthcare</subject></subj-group></article-categories><title-group><article-title>
 
 
  Contrast-Enhanced Mammogram: A New Game-Changer in Breast Imaging. Indications with Case-Based Experience
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Chotai</surname><given-names>Niketa</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Loke</surname><given-names>Siu Cheng</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Tan</surname><given-names>Ern Yu</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib></contrib-group><aff id="aff3"><addr-line>Department of Surgery, Tan Tock Seng Hospital, Singapore</addr-line></aff><aff id="aff2"><addr-line>Department of Diagnostic Imaging, Tan Tock Seng Hospital, Singapore</addr-line></aff><aff id="aff1"><addr-line>RadLink Diagnostic Imaging Center, Visiting Consultant, Department of Radiology, Tan Tock Seng Hospital, Singapore</addr-line></aff><pub-date pub-type="epub"><day>16</day><month>08</month><year>2021</year></pub-date><volume>10</volume><issue>04</issue><fpage>184</fpage><lpage>199</lpage><history><date date-type="received"><day>20,</day>	<month>August</month>	<year>2021</year></date><date date-type="rev-recd"><day>5,</day>	<month>October</month>	<year>2021</year>	</date><date date-type="accepted"><day>8,</day>	<month>October</month>	<year>2021</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Mammograms are the mainstay of diagnostic breast imaging and cancer
   screening. Despite advances in technology such as Full Field Digital Mammography (FFDM) and Digital Breast Tomosynthesis (DBT), these imaging techniques are purely structural, and are unable to overcome shortcomings in mammography posed by dense breast parenchyma. Magnetic Resonance Imaging (MRI) is the most sensitive modality in breast imaging, due to 
  its 
  functional aspect
  s in addition to structural imaging with this modality. The use of MRI is however constrained by cost and availability. 
  The 
  utilization of intravenous contrast with mammograms introduces a functional element to imaging. This greatly improves the sensitivity of the examination, approaching sensitivity levels of Magnetic Resonance Imaging (MRI) in the detection of primary breast cancer. With increased sensitivity afforded by assessment of tumor neo
  -
  vascularity, as well as its low cost, low energy
   imaging that is more readily available than MRI, Contrast
  -
  Enhanced Mammography (CEM) if more readily available than MRI, this imaging modality is a potential
   game
  -
  changer in breast imaging. In this article, we share our experience in the use of CEM, for indications previously reserved for MRI, with 
  the 
  literature review of these indications. In resonance with prior studies, we echo the ease of performing and reporting of CEM as well as greater patient comfort as the distinct advantages of CEM. In spite of slightly higher radiation dose and some risk
  s
   related to contrast media, functional results at 
  a 
  significantly lower cost may change h
  ow we practice breast imaging in 
  the 
  future using CEM.
 
</p></abstract><kwd-group><kwd>Contrast-Enhanced Mammography</kwd><kwd> Clinical Use</kwd><kwd> Advantages</kwd><kwd> Indications</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>A mammogram is the most frequently used modality for diagnostic breast imaging and cancer screening [<xref ref-type="bibr" rid="scirp.112360-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref2">2</xref>], in no small part to its widespread availability, short examination time, reproducibility, ease of interpretation and ability to detect microcalcifications. Dense breast parenchyma is a major limiting factor that reduces the sensitivity of the mammogram by nearly half in extremely dense breast tissue [<xref ref-type="bibr" rid="scirp.112360-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref4">4</xref>]. Though tomosynthesis [<xref ref-type="bibr" rid="scirp.112360-ref5">5</xref>] partly overcomes this limitation by reducing tissue overlap to some degree, these techniques remain purely morphology-based.</p><p>By contrast, breast Magnetic Resonance Imaging (MRI) is highly sensitive, with a functional element of imaging using intravenous contrast, in addition to its superior soft-tissue contrast and three-dimensional format; this allows for an examination independent of breast density [<xref ref-type="bibr" rid="scirp.112360-ref6">6</xref>]. The use of intravenous contrast leverages in imaging characteristics of tumor neo-angiogenesis, and significantly increases sensitivity in breast cancer detection [<xref ref-type="bibr" rid="scirp.112360-ref7">7</xref>]. In addition to its anatomical advantage through three-dimensional visualization, there is better coverage of the chest wall, axilla, and internal mammary nodes. Despite its high sensitivity, routine use of MRI in clinical practice is restricted by issues of accessibility (financial costs, long waiting times), technical performance (long scan time, difficulties in patients with claustrophobia) as well as diagnosis (high-false positive rates, inability to detect microcalcifications).</p><p>Contrast-Enhanced Mammogram (CEM) aims to address the shortcomings of conventional mammography, by introducing an element of functional imaging, similar to breast MRI.</p><p>Dual-energy mammogram exposures are obtained after intravenous injection of iodine-based contrast agent. The low-energy exposure produces an image that is similar to a conventional Full-Field Digital Mammogram (FFDM), while the recombined image obtained from the subtraction of two images provides details of contrast enhancement in the breast. It does not require substantial training for technologists already involved in mammography and is easy to perform. For the radiologist, there is no significant departure from interpretation in conventional mammography. The additional recombined images allow for detection of lesions that show contrast enhancement which indicates increased vascularity, which may suggest underlying neo-angiogenesis such as in breast cancer.</p><p>Studies have already shown CEM to have higher sensitivity than mammograms, tomosynthesis, or even a combination of mammograms and ultrasound [<xref ref-type="bibr" rid="scirp.112360-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref9">9</xref>]. In fact, many studies have shown CEM results to be nearly comparable to Dynamic Contrast-Enhanced MRI (DCE-MRI), which is encouraging.</p><p>This article aims to share our initial clinical experience of using CEM. Indications for performing breast MRI were similarly applied to CEM, given CEM’s high sensitivity being similar to breast MRI, allowing for contrast and comparison and to illustrate its usefulness in clinical practice.</p><p>The clinical indications are:</p><p>&#183; To assess the extent of breast cancer or for pre-operative cancer staging;</p><p>&#183; To monitor the response to neo-adjuvant chemotherapy;</p><p>&#183; To look for residual or recurrent breast cancer;</p><p>&#183; Surveillance in women with a personal history of breast cancer;</p><p>&#183; Problem-solving in equivocal findings on conventional imaging;</p><p>&#183; Screening in high-risk women.</p><p>We share our experience with cases of CEM used for individual indication instead of MRI, followed by indication-specific literature review and discussion.</p></sec><sec id="s2"><title>2. Discussion</title><sec id="s2_1"><title>2.1. To Assess the Extent of Breast Cancer or for Pre-Operative Cancer Staging</title><p>MRI is well-established as a modality to assess loco-regional extent of breast cancer pre-operatively. This is especially useful in young women, women with dense breasts, invasive lobular carcinoma and Locally Advanced Breast Cancer (LABC). Accurate assessment of disease extent is an important determining factor in the decision for Breast Conserving Surgery (BCS) versus mastectomy. In LABC, involvement of chest wall and internal mammary nodes are better assessed with MRI, the presence of which may influence the management.</p><p>Case 1: A 42-year-old woman presented with a palpable left breast lump. Mammogram (<xref ref-type="fig" rid="fig1">Figure 1</xref>(A)) showed extremely dense breast parenchyma (ACR category D) with a suspicious mass in the left breast at 12 o’clock. Ultrasound (<xref ref-type="fig" rid="fig1">Figure 1</xref>(B)) confirmed a corresponding BI-RADS 5 mass at 12 o’clock and additionally a smaller indeterminate lesion at 11 o’clock in the same breast, raising possibility of multifocal cancer. Pre-operative CEM was offered for better assessment of disease extent and to rule out synchronous right breast tumor. On CEM (<xref ref-type="fig" rid="fig1">Figure 1</xref>(C)), intensely enhancing masses were seen in left breast at 11 and 12 o’clock, correlating with ultrasound findings. Additionally, moderately enhancing non-mass enhancement was identified at 2 o’clock of the same breast. Targeted second look ultrasound (<xref ref-type="fig" rid="fig1">Figure 1</xref>(D)) of left breast 2 o’clock region identified an ill-defined mixed echogenic lesion that was also biopsied. Histology from 12 o’clock lesion was reported as a Grade 3 invasive ductal carcinoma while the 2 o’clock lesion was reported as intermediate grade DCIS. This confirmed the disease to be multicentric, changing the overall disease extent, treatment plan as well as prognosis. No enhancing lesions were noted in the contralateral breast on CEM and this was reassuring of absent synchronous tumor.</p><p>Case 2: A 48-year-old woman presented with left breast palpable mass; clinically worrisome for breast cancer. Direct CEM was performed for this patient. Low energy images (<xref ref-type="fig" rid="fig2">Figure 2</xref>(A)), similar to a regular mammogram, showed a high density, irregular mass in the upper outer quadrant of the left breast. No other lesion was identified in rest of breast on mammogram. Contrast enhanced images (<xref ref-type="fig" rid="fig2">Figure 2</xref>(B)) showed a single, avidly enhancing mass in the upper outer quadrant of the left breast at mid third depth. No other concerning enhancement</p><p>was seen in the left breast suggesting this to be a unifocal tumor. Contralateral breast did not show any synchronous tumor. Targeted ultrasound of left breast (<xref ref-type="fig" rid="fig2">Figure 2</xref>(C)) showed a suspicious correlating mass at the 2 o’clock location, which was later biopsy proven as Grade 2 invasive ductal carcinoma. By using direct CEM, we could get mammographic details as well as make better assessment of disease extent at the first instance that would facilitate quicker treatment planning.</p><p>Literature review</p><p>Stephanie A Lee-Felker et al. [<xref ref-type="bibr" rid="scirp.112360-ref10">10</xref>] compared the diagnostic performances of CEM and breast MR imaging in assessing the extent of disease in women with newly diagnosed breast cancer. In their study, CEM showed sensitivity close to MRI (94% vs 99%) in detecting primary breast cancer, a significantly higher PPV (93% vs 60%), and fewer false-positive results compared to MR imaging (5 vs 45) (P &lt; 0.001 for all results). Yun-Chung Cheung et al. [<xref ref-type="bibr" rid="scirp.112360-ref11">11</xref>] in their study on 51 primary cancers showed 88% sensitivity on mammogram versus 100% on CEM</p><p>and MRI. The tumor size also better correlated with CEM and MRI. Multiple other studies comparing CEM to MRI have also reported equivalent sensitivity of CEM in detecting primary breast cancer with lower false positive rate on CEM [<xref ref-type="bibr" rid="scirp.112360-ref12">12</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref13">13</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref14">14</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref15">15</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref16">16</xref>].</p><p>Hobbs et al. [<xref ref-type="bibr" rid="scirp.112360-ref17">17</xref>] in their prospective trial on 49 cases compared patient preference on CEM versus MRI for pre-operative staging. Patients reportedly preferred the experience of CEM to MRI, adding support for the role of CEM as a possible alternative to MRI for breast cancer staging.</p><p>Thus, CEM appears to be a promising alternative pre-operative assessment tool for breast cancer patients with dense breasts and/or limited access or contraindications to MRI. At our center, we try to offer direct CEM, rather than FFDM, and targeted ultrasound to patients with high clinical suspicion of breast cancer. This allows for a quicker and more accurate estimation of tumor extent, with reduced cost and radiation to the patient.</p></sec><sec id="s2_2"><title>2.2. To Monitor the Response to Neo-Adjuvant Chemotherapy</title><p>Recently, use of Neo-Adjuvant Chemotherapy (NAC) is expanding in clinical practice, not only for locally advanced breast cancer but also in smaller triple negative and HER2-positive cancers. The pathological response to NAC has prognostic significance and influences the subsequent surgical approach. Response to NAC is assessed by clinical examination and imaging. MRI has been shown to be the most sensitive imaging modality, at present, to monitor response to NAC. Due to limitations like financial constraint, resource availability and claustrophobia, MRI may not be suitable in all patients post-NAC. CEM may be an alternative in this instance.</p><p>Case 1: A 60-year-old woman with a palpable left breast invasive ductal carcinoma with positive left axillary lymphadenopathy underwent CEM pre and post-NAC. Baseline CEM (<xref ref-type="fig" rid="fig3">Figure 3</xref>(A) showed avidly enhancing left breast tumor with internal heterogeneity and enlarged metastatic left axillary node. Post-NAC CEM (<xref ref-type="fig" rid="fig3">Figure 3</xref>(B)) was performed to assess the suitability for breast conservation. The primary tumor in the left breast showed significant regression of enhancement. A tissue marker clip was seen in the tumor bed. Imaging features were deemed to indicate complete radiological response to NAC. The left axillary node had also regressed. On final surgical histopathology, a 2mm residual focus of invasive ductal carcinoma was noted. The axillary nodes were negative for malignancy on final histology.</p><p>Case 2: Another 46-year-old woman diagnosed with multicentric right breast tumor with metastatic right axillary adenopathy (<xref ref-type="fig" rid="fig3">Figure 3</xref>(C) and <xref ref-type="fig" rid="fig3">Figure 3</xref>(D))</p><p>showed small area of faint residual enhancement in the tumor bed on post-NAC CEM. The axillary node was also seen enhancing. Final surgical histopathology confirmed residual 16 mm, grade 3 IDC along with residual metastatic axillary node.</p><p>Literature review</p><p>At present, MRI has been proven to be the most sensitive imaging modality for detecting residual disease, post NAC [<xref ref-type="bibr" rid="scirp.112360-ref18">18</xref>]. Neo-adjuvant chemotherapy has become the standard of care in advanced breast cancers as it facilitates down-staging and increases the likelihood for successful breast conservation. It is also a good tool to assess in-situ chemosensitivity and hence to predict treatment outcomes and prognosis.</p><p>In their prospective study on 33 breast cancer patients, Filipe et al. [<xref ref-type="bibr" rid="scirp.112360-ref19">19</xref>] compared CEM and MRI with surgical histopathology in post-NAC patients. While sensitivity of CEM in detecting residual disease was lower compared to MRI (76% Vs 92%), the specificity and negative predictive value of CEM were higher compared to MRI (87.5% vs 75% and 86.4% vs75%, respectively). The concordance coefficients between measurements of residual tumor obtained with CEM and MRI as compared to surgical pathology were 0.7 and 0.4, respectively. Similarly, Pearson correlation coefficient was higher for CEM (0.8) versus MRI (0.5). Lotti et al. [<xref ref-type="bibr" rid="scirp.112360-ref20">20</xref>] reported that the residual tumor size was underestimated on both modalities (mean 4.1 mm in CESM, 7.5 mm in MRI). Also, in patients with Complete Response (CR), CEM had higher sensitivity and specificity (100% and 84%, respectively) compared to MRI (87% and 60%, respectively).</p></sec><sec id="s2_3"><title>2.3. To Look for Residual or Recurrent Breast Cancer</title><p>In patients treated with breast conservation therapy, any new finding may raise concern of a recurrence. Changes such as post-operative seroma, fat necrosis, skin thickening, architectural distortion and dystrophic calcifications, may pose a diagnostic dilemma on conventional imaging. Differentiating benign post-therapeutic change versus recurrence is clinically important, but may prove challenging in some cases, requiring biopsy for a definitive answer. In these cases, breast MRI may be used as a problem-solving tool; CEM might be seen as a potential alternative.</p><p>Case 1: A 46-year-old woman with previous right breast wide local excision for hormone positive, HER2 negative breast cancer 7 years ago presented with a new palpable lump, adjacent to the scar. Ultrasound (<xref ref-type="fig" rid="fig4">Figure 4</xref>(A)) showed a 2.6 cm mixed echogenic lesion with indeterminate features corresponding to the palpable lump. Mammogram showed dense breast parenchyma without any suspicious features. Tissue diagnosis was suggested for the patient to rule out a recurrence. Pre-biopsy CEM revealed no contrast enhancement in the region of the palpable concern (<xref ref-type="fig" rid="fig4">Figure 4</xref>(B)). Histology performed later confirmed the lesion to be post-operative fibrosis with benign breast tissue.</p><p>Case 2: A 52-year-old woman with a similar history of a new palpable lump in</p><p>the region of a previous wide excision scar was referred to the imaging suite for further assessment. The patient was operated 6 years ago for hormone-positive, HER2 negative, grade 2 Invasive ductal carcinoma with metastatic axillary adenopathy. Ultrasound (<xref ref-type="fig" rid="fig4">Figure 4</xref>(C)) revealed an indeterminate hypoechoic lesion underneath the palpable concern. Initial biopsy was reported as benign breast tissue with post-operative changes. Radiology-pathology concordance was questioned. Contrast enhanced mammogram was then performed that showed the lesion to enhance avidly (<xref ref-type="fig" rid="fig4">Figure 4</xref>(D)). This was considered a finding of concern and histology was deemed discordant. A repeat ultrasound guided biopsy was carried out, which confirmed invasive ductal carcinoma recurrence. In this case, findings on CEM bolstered initial imaging suspicions which were discordant on pathology, making the case for repeat biopsy and subsequent proof of disease recurrence.</p><p>Literature review</p><p>At present there is limited literature on the use of CEM in the diagnosis of recurrence and further research is warranted. Helal and Mansour et al. [<xref ref-type="bibr" rid="scirp.112360-ref21">21</xref>] assessed the role of CEM in detecting residual disease in post-operative breast of cancer patients. CEM enhanced the sensitivity of detecting breast cancer from 50% to 91.17% and increased accuracy from 37% to 82% as compared to conventional mammogram. However, the data remains limited in this context and needs further evaluation.</p></sec><sec id="s2_4"><title>2.4. Surveillance in Patients with Personal History of Breast Cancer</title><p>Despite advancements in breast cancer treatment, disease recurrence after successful initial treatment remains a real concern. Annual mammography is currently the gold standard for surveillance in post-operative breast [<xref ref-type="bibr" rid="scirp.112360-ref22">22</xref>]. Additional ultrasound and MRI may be performed in cases of suspicious findings on conventional imaging. In their recent recommendations, the American College of Radiologists (ACR) have included adjuvant annual MRI surveillance for patients with a personal history of breast cancer at pre-menopausal age, especially if associated with dense breasts or other high-risk factors like positive family history. This may however not be routinely practiced at many places, due to limitations such as high cost and high false positive results. CEM may be considered as an alternative to breast MRI in such cases.</p><p>Case 1: A 64-year-old woman with previous personal history of right mastectomy for breast cancer was detected to have a new 5mm group of punctate microcalcifications in the left breast on routine surveillance mammogram (<xref ref-type="fig" rid="fig5">Figure 5</xref>(A)). On ultrasound, a 5 mm indeterminate hypoechoic lesion with internal microcalcifications (<xref ref-type="fig" rid="fig5">Figure 5</xref>(B)) was identified to correlate with the mammographic abnormality. Pre-biopsy CEM (<xref ref-type="fig" rid="fig5">Figure 5</xref>(C)) showed a 16 mm area of non-mass enhancement in the region of grouped microcalcifications. The extent of enhancement was larger on CEM compared to conventional imaging.</p><p>Biopsy of the lesion confirmed a high-grade DCIS with foci of microinvasion. Final surgical histology proved the tumor to be 20 mm with 2 mm of invasive component; the size better correlating with CEM than mammogram or ultrasound. We postulate that the non-calcified portion of cancer was better demonstrated on contrast study and CEM could have resulted in earlier detection of the recurrence.</p><p>Literature review</p><p>A few studies have already established the superiority of CEM over conventional mammogram for breast cancer screening [<xref ref-type="bibr" rid="scirp.112360-ref23">23</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref24">24</xref>]. In a study by Sung et al. [<xref ref-type="bibr" rid="scirp.112360-ref24">24</xref>] of 904 women with higher-than-average risk, they reported 87% sensitivity and 93.7% specificity of CEM compared to only 50% sensitivity for mammogram. Nearly half the women in this study had a personal history of previous breast cancer. They reported CEM accuracy to be comparable to MRI in moderate to high-risk screening populations. No dedicated study has compared CEM with MRI in this group of population though. This opens scope for further research.</p></sec><sec id="s2_5"><title>2.5. Problem Solving in Equivocal Findings on Conventional Imaging</title><p>The diagnostic accuracy of digital mammography is highly dependent on density of fibroglandular tissue, with dense parenchyma adversely affecting the sensitivity. Frequently, focal asymmetry and architectural distortion without any associated mass may present diagnostic challenges. Occasionally, ultrasound may have findings with borderline features and contribute to false positive biopsies. CEM can be used for further assessment in such patients and help the radiologist in assigning a more confident BIRADS category to the mammogram.</p><p>Case 1: A 53-year-old woman had a known history of left mastectomy for breast cancer. Routine surveillance right mammogram was essentially normal. Adjuvant right breast ultrasound detected a new 8 mm irregular hypoechoic mass at 12 o’clock with angular margins and associated subtle architectural distortion (<xref ref-type="fig" rid="fig6">Figure 6</xref>(A)). Ultrasound guided core biopsy of the mass revealed usual ductal hyperplasia without any evidence of malignancy. However, the patient was apprehensive and was keen for surgery, even requesting a mastectomy. CEM was performed as a problem-solving technique. CEM (<xref ref-type="fig" rid="fig6">Figure 6</xref>(B)) showed no enhancement in the right breast at 12 o’clock, favoring benign etiology. The patient was reassured and agreed for follow up. On serial imaging, the lesion remained stable over 2 years.</p><p>Literature review</p><p>Lalji et al. [<xref ref-type="bibr" rid="scirp.112360-ref25">25</xref>] reported CEM to be superior to mammography with an excellent problem-solving capability in patients recalled from screening program. CEM was shown to have higher sensitivity of up to 97% and specificity of up to 70% and improved diagnostic accuracy regardless of the reader’s experience.</p><p>Lobbes et al. [<xref ref-type="bibr" rid="scirp.112360-ref26">26</xref>] prospectively analyzed the role of CEM in 113 women to address inconclusive findings on screening mammography. They reported 100%</p><p>sensitivity as well as 100% Negative predictive values of CEM with statistically significant differences between mammogram and CEM. They reported better diagnostic accuracy of CEM even in average risk screening population recalled for assessment.</p><p>Houben et al. [<xref ref-type="bibr" rid="scirp.112360-ref27">27</xref>] retrospectively analyzed 839 women who underwent CEM after a screening recall. They found 70 CESM only lesions in 65 women; more than 50% of them were malignant. The most commonly detected benign abnormality on CEM was fibroadenoma. They reported CEM as a low risk, problem solving tool in screening recalls that might have significant clinical implications in patient’s management.</p></sec><sec id="s2_6"><title>2.6. Screening in High-Risk Woman</title><p>Women with lifetime risk of &gt;20% are grouped as high-risk population. The American Cancer Society (ACS) recommends annual screening with MRI and mammography in these women. Again, annual MRI screening may be not feasible or followed as recommended in many countries due to cost constraints. CEM may be utilized as an alternative tool to MRI in high-risk screening based on the current evidence suggesting comparable diagnostic performance of CEM over MRI with high negative predictive value [<xref ref-type="bibr" rid="scirp.112360-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref12">12</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref13">13</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref15">15</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref16">16</xref>].<sup> </sup></p><p>Case 1: A 69-year-old woman with a strong family history of breast cancer in multiple relatives underwent screening mammogram. Mammogram (<xref ref-type="fig" rid="fig6">Figure 6</xref>(C)) showed dense breast parenchyma. A round, sub-centimeter, circumscribed opacity was observed in the right breast pre-pectoral fat. In view of the dense breast tissue and strong family history, she was offered additional screening with CEM. The right breast showed an intra-mammary lymph node. However, an avidly enhancing mass was detected in the left breast (<xref ref-type="fig" rid="fig6">Figure 6</xref>(D)). Targeted ultrasound showed an intra-mammary node in the right breast and a lobulated, indeterminate hypoechoic nodule in the left breast that was proven to be an in-situ 24 mm papillary carcinoma with solid and cribriform component; ER/PR positive.</p><p>Literature review</p><p>Sorin et al. [<xref ref-type="bibr" rid="scirp.112360-ref28">28</xref>] reported the usefulness of CEM in high-risk screening. They reported a significantly high, additional 13.1 cancers on CEM per 1000 intermediate risk women screened, compared to screening mammography. There was significantly higher sensitivity of CEM, up to 90.5%, compared to mammogram which showed sensitivity of up to 52.4%.</p><p>Jordana Phillips et al. [<xref ref-type="bibr" rid="scirp.112360-ref29">29</xref>] compared CEM versus MRI in high risk setting primarily evaluating in terms of patient preferences. They did prospective analysis of 43 patients in high risk setting and showed that 79% patients preferred CEM over MRI if the exams had equal sensitivity. Almost 89% would be comfortable receiving contrast as part of an annual screening test and about 97% found the duration of CESM perfect for a screening test. They concluded that a high-risk population may prefer CEM as a screening tool, if ongoing trials demonstrate its results as being non-inferior to MRI.</p></sec><sec id="s2_7"><title>2.7. To Evaluate Cancers of Unknown Primary with Metastatic Axillary Lymphadenopathy</title><p>MR imaging has already been established as the most sensitive modality for the detection of occult breast cancer in women who present with metastatic axillary adenopathy [<xref ref-type="bibr" rid="scirp.112360-ref30">30</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref31">31</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref32">32</xref>]. The identification of primary lesion is very important from the management perspective. The conventional treatment approach for occult breast cancer is mastectomy. However, if a primary lesion can be identified in a breast pre-operatively, the option of breast conservation may be offered to the patient.</p><p>CEM has shown similar sensitivity to MRI in detection of breast cancer [<xref ref-type="bibr" rid="scirp.112360-ref33">33</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref34">34</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref35">35</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref36">36</xref>] [<xref ref-type="bibr" rid="scirp.112360-ref37">37</xref>] and may play an important role in such patients. There is no study currently showing the role of CEM in the detection of occult breast cancer. However, with ongoing improvements in CEM techniques, and better understanding and interpretation of images, CEM may be offered to patients as a primary tool where there is limited availability of MRI. Further research is warranted.</p></sec></sec><sec id="s3"><title>3. Conclusions</title><p>Multiple studies comparing CEM to MRI have shown CEM to have equivalent diagnostic efficiency with fewer false-positive results. Larger multicenter trials are expected to validate the use of CEM as an alternate to MRI in many indications. Distinct advantages of CEM include faster imaging and interpretation time, greater ease of scheduling the examination, lower cost, better patient comfort and lack of claustrophobia. Limitations of CEM include slightly increased radiation dose, contrast media reactions and inability to use this modality in patients with compromised renal function.</p><p>It is also important to remember that some benign lesions may also enhance on CEM, contributing to false-positive results. Hence, CEM is better interpreted in combination with morphological features of lesions on ultrasound. At this time, CEM may be considered as an option in cases where MRI is contraindicated or not available, e.g. in patients with MR incompatible cardiac pacemaker, claustrophobia, limited resources and cost issue.</p></sec><sec id="s4"><title>Teaching Points</title><p>1) CEM is a new emerging modality in breast imaging that combines the advantages of mammograms and MRI;</p><p>2) Sensitivity of CEM is comparable to MRI;</p><p>3) Indications of CEM are nearly similar to that of MRI and at this time, CEM may be considered as an option in cases where MRI is contraindicated or not available;</p><p>4) CEM uses iodinated contrast similar to CT scan. It is contraindicated in patients with severe drug allergies, renal impairment and active asthma.</p></sec><sec id="s5"><title>Acknowledgements</title><p>The authors would like to acknowledge Dr. Rishu Sangal for her assistance in reviewing the literature.</p></sec><sec id="s6"><title>Funding</title><p>The cases were partly funded by the “Pitch for Fund Program” at Tan Tock Seng Hospital and “National Medical Research Council CSA grant (MOH-000279)”.</p></sec><sec id="s7"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s8"><title>Cite this paper</title><p>Niketa, C., Cheng, L.S. and Yu, T.E. (2021) Contrast-Enhanced Mammogram: A New Game-Changer in Breast Imaging. Indications with Case-Based Experience. Advances in Breast Cancer Research, 10, 184-199. https://doi.org/10.4236/abcr.2021.104016</p></sec></body><back><ref-list><title>References</title><ref id="scirp.112360-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Fallenberg, E.M., Dromain, C., Diekmann, F., Engelken, F., Krohn, M., Singh, J.M., Ingold-Heppner, B., Winzer, K.J., Bick, U. and Renz, D.M. (2014) Contrast-Enhanced Spectral Mammography versus MRI: Initial Results in the Detection of Breast Cancer and Assessment of Tumour Size. European Radiology, 24, 256-264.  
https://doi.org/10.1007/s00330-013-3007-7</mixed-citation></ref><ref id="scirp.112360-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Luczyńska, E., Heinze-Paluchowska, S., Hendrick, E., Dyczek, S., Rys, J., Herman, K., Blecharz, P., and Jakubowicz, J. (2015) Comparison between Breast MRI and Contrast-Enhanced Spectral Mammography. Medical Science Monitor, 21, 1358-1367. 
https://doi.org/10.12659/MSM.893018</mixed-citation></ref><ref id="scirp.112360-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Lewin, J. (2018) Comparison of Contrast-Enhanced Mammography and Contrast-Enhanced Breast MR Imaging. Magnetic Resonance Imaging Clinics of North America, 26, 259-263. https://doi.org/10.1016/j.mric.2017.12.005</mixed-citation></ref><ref id="scirp.112360-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Hobbs, M.M., Taylor, D.B., Buzynski, S., et al. (2015) Contrast-Enhanced Spectral Mammography (CESM) and Contrast Enhanced MRI (CEMRI): Patient Preferences and Tolerance. Journal of Medical Imaging and Radiation Oncology, 59, 300-305.  
https://doi.org/10.1111/1754-9485.12296</mixed-citation></ref><ref id="scirp.112360-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Lobbes, M.B., Prevos, R., Smidt, M., et al. (2013) The Role of Magnetic Resonance Imaging in Assessing Residual Disease and Pathologic Complete Response in Breast Cancer Patients Receiving Neoadjuvant Chemotherapy: A Systematic Review. Insights into Imaging, 4, 163-75. https://doi.org/10.1007/s13244-013-0219-y</mixed-citation></ref><ref id="scirp.112360-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Barra, F.R., Sobrinho, A.B., Barra, R.R., et al. (2018) Contrast-Enhanced Mammography (CEM) for Detecting Residual Disease after Neoadjuvant Chemotherapy: A Comparison with Breast Magnetic Resonance Imaging (MRI). BioMed Research International, 2018, Article ID: 8531916. https://doi.org/10.1155/2018/8531916</mixed-citation></ref><ref id="scirp.112360-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Iotti, V., Ravaioli, S., Vacondio, R., et al. (2017) Contrast-Enhanced Spectral Mammography in Neoadjuvant Chemotherapy Monitoring: A Comparison with Breast Magnetic Resonance Imaging. Breast Cancer Research, 19, Article No. 106. 
https://doi.org/10.1186/s13058-017-0899-1</mixed-citation></ref><ref id="scirp.112360-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Hetal, M.H., Mansour, S.M., Ahmed, H.A., et al. (2019) Role of Contrast Enhanced Spectral Mammography in the Evaluation of Post-Operative Breast Cancer. Clinical Radiology, 74, 771-781. https://doi.org/10.1016/j.crad.2019.06.002</mixed-citation></ref><ref id="scirp.112360-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Swinnen, J., Keupers, M., Soens, J., et al. (2018) Breast Imaging Surveillance after Curative Treatment for Primary Non-Metastasised Breast Cancer in Non-High-Risk Women: A Systematic Review. Insights into Imaging, 9, 961-970.  
https://doi.org/10.1007/s13244-018-0667-5</mixed-citation></ref><ref id="scirp.112360-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Kim, G., Phillips, J., Cole, E., et al. (2019) Comparison of Contrast-Enhanced Mammography with Conventional Digital Mammography in Breast Cancer Screening: A Pilot Study. Journal of the American College of Radiology, 16, 1456-1463.  
https://doi.org/10.1016/j.jacr.2019.04.007</mixed-citation></ref><ref id="scirp.112360-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Sung, J.S., Lebron, L., Keating, D., et al. (2019) Performance of Dual-Energy Contrast-Enhanced Digital Mammography for Screening Women at Increased Risk of Breast Cancer. Radiology, 293, 81-88. https://doi.org/10.1148/radiol.2019182660</mixed-citation></ref><ref id="scirp.112360-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Lalji, U.C., Houben, I.P., Prevos, R., et al. (2016) Contrast-Enhanced Spectral Mammography in Recalls from the Dutch Breast Cancer Screening Program: Validation of Results in a Large Multireader, Multicase Study. European Radiology, 26, 4371-4379. 
https://doi.org/10.1007/s00330-016-4336-0</mixed-citation></ref><ref id="scirp.112360-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Lobbes, M.B., Lalji, U., Houwers, J., et al. (2014) Contrast-Enhanced Spectralmammography in Patients Referred from the Breast Cancer Screening Programme. European Radiology, 24, 1668-1676. 
https://doi.org/10.1007/s00330-014-3154-5</mixed-citation></ref><ref id="scirp.112360-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Sogani, J., Mango, V.L., Keating, D., Sung, J.S. and Jochelson, M.S. (2021) Contrast-Enhanced Mammography: Past, Present, and Future. Clinical Imaging, 69, 269-279. 
https://doi.org/10.1016/j.clinimag.2020.09.003</mixed-citation></ref><ref id="scirp.112360-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Xiang, W., Rao, H. and Zhou, L. (2020) A Meta-Analysis of Contrast-Enhanced Spectral Mammography versus MRI in the Diagnosis of Breast Cancer. Thoracic Cancer, 11, 1423-1432. https://doi.org/10.1111/1759-7714.13400</mixed-citation></ref><ref id="scirp.112360-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Suter, M.B., Pesapane, F., Agazzi, G.M., Gagliardi, T., Nigro, O. Bozzini, A., Priolo, F., Penco, S., Cassano, E., Chini, C. and Squizzato, A. (2020) Diagnostic Accuracy of Contrast-Enhanced Spectral Mammography for Breast Lesions: A Systematic Review and Meta-Analysis. Breast, 53, 8-17. 
https://doi.org/10.1016/j.breast.2020.06.005</mixed-citation></ref><ref id="scirp.112360-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Tagliafico, A.S., Bignotti, B., Rossi, F., Signori, A., Sormani M.P., Valdora, F., Calabrese, M. and Houssami, N. (2016) Diagnostic Performance of Contrast-Enhanced Spectral Mammography: Systematic Review and Meta-Analysis. Breast, 28, 9-13. https://doi.org/10.1016/j.breast.2016.04.008</mixed-citation></ref><ref id="scirp.112360-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Zhu, X., Huang, J.M., Zhang, K., et al. (2018) Diagnostic Value of Contrast-Enhanced Spectral Mammography for Screening Breast Cancer: Systematic Review and Meta-Analysis. Clinical Breast Cancer, 18, E985-E995.  
https://doi.org/10.1016/j.clbc.2018.06.003</mixed-citation></ref><ref id="scirp.112360-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Morris, E.A., Liberman, L., Ballon, D.J., et al. (2003) MRI of Occult Breast Carcinoma in a High Risk Population. American Journal of Roentgenology, 181, 619-626.  
https://doi.org/10.2214/ajr.181.3.1810619</mixed-citation></ref><ref id="scirp.112360-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Buchanan, C.L., Morris, E.A., Doru, P.L., Borgen, P.I. and Van Zee, K.J. (2005) Utility of Breast Magnetic Resonance Imaging in Patients with Occult Primary Breast Cancer. Annals of Surgical Oncology, 12, 1045-1053. 
https://doi.org/10.1245/ASO.2005.03.520</mixed-citation></ref><ref id="scirp.112360-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Orel, S.G., Weinstein, S.P., Schnall, M.D., et al. (1999) Breast MR Imaging in Patients with Axillary Node Metastases and Unknown Primary Malignancy. Radiology, 212, 543-549. https://doi.org/10.1148/radiology.212.2.r99au40543</mixed-citation></ref><ref id="scirp.112360-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Phillips, J., Miller, M.M., Mehta, T.S., et al. (2017) Contrast-Enhanced Spectral Mammography (CESM) versus MRI in the High-Risk Screening Setting: Patient Preferences and Attitudes. Clinical Imaging, 42, 193-197.  
https://doi.org/10.1016/j.clinimag.2016.12.011</mixed-citation></ref><ref id="scirp.112360-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Sorin, V., Yagil, Y., Yosepovich, A., et al. (2018) Contrast-Enhanced Spectral Mammography in Women with Intermediate Breast Cancer Risk and Dense Breasts. American Journal of Roentgenology, 211, W267-W274.  
https://doi.org/10.2214/AJR.17.19355</mixed-citation></ref><ref id="scirp.112360-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Houben, I.P.L, Van de Voorde, P., Jeukens, C.R.L.P.N., et al. (2017) Contrast-Enhanced Spectral Mammography as Work-Up Tool in Patients Recalled from Breast Cancer Screening Has Low Risks and Might Hold Clinical Benefits. European Journal of Radiology, 94, 31-37. https://doi.org/10.1016/j.ejrad.2017.07.004</mixed-citation></ref><ref id="scirp.112360-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Jochelson, M.S., Dershaw, D.D., Sung, J.S., Heerdt, A.S., Thornton, C., Moskowitz, C.S., Ferrara, J. and Morris, E.A. (2013) Bilateral Contrast-Enhanced Dual-Energy Digital Mammography: Feasibility and Comparison with Conventional Digital Mammography and MR Imaging in Women with Known Breast Carcinoma. Radiology, 266, 743-751. https://doi.org/10.1148/radiol.12121084</mixed-citation></ref><ref id="scirp.112360-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">Dromain, C., Canale, S., Bidault, F., et al. (2011) Dual-Energy Contrast-Enhanced Digital Mammography: Initial Clinical Results. European Radiology, 21, 565-574.</mixed-citation></ref><ref id="scirp.112360-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">Cheung, Y.C., Juan, Y.H., Lo, Y.F., Lin, Y.-C., Yeh, C.-H. and Ueng, S.-H. (2020) Preoperative Assessment of Contrast-Enhanced Spectral Mammography of Diagnosed Breast Cancers after Sonographic Biopsy: Correlation to Contrast-Enhanced Magnetic Resonance Imaging and 5-Year Postoperative Follow-Up. Medicine, 99, e19024. https://doi.org/10.1097/MD.0000000000019024</mixed-citation></ref><ref id="scirp.112360-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">Lee-Felker, S.A., Tekchandani, L., Thomas, M., Gupta, E., Andrews-Tang, D., Roth, A., Sayre, J. and Rahbar, G. (2017) Newly Diagnosed Breast Cancer: Comparison of Contrast-enhanced Spectral Mammography and Breast MR Imaging in the Evaluation of Extent of Disease. Radiology, 285, 389-400. 
https://doi.org/10.1148/radiol.2017161592</mixed-citation></ref><ref id="scirp.112360-ref29"><label>29</label><mixed-citation publication-type="other" xlink:type="simple">Mori, M., Akashi-Tanaka, S., Suzuki, S., Daniels, M.I., Watanabe, C., Hirose, M. and Nakamura, S. (2017) Diagnostic Accuracy of Contrast-Enhanced Spectral Mammography in Comparison to Conventional Full-Field Digital Mammography in a Population of Women with Dense Breasts. Breast Cancer, 24, 104-110. 
https://doi.org/10.1007/s12282-016-0681-8</mixed-citation></ref><ref id="scirp.112360-ref30"><label>30</label><mixed-citation publication-type="other" xlink:type="simple">Fallenberg, E.M., Dromain, C., Diekmann, F., Engelken, F., Krohn, M., Singh, J.M., Ingold-Heppner, B., Winzer, K.J., Bick, U. and Renz, D.M. (2014) Contrast-Enhanced Spectral Mammography versus MRI: Initial Results in the Detection of Breast Cancer and Assessment of Tumour Size. European Radiology, 24, 256-264.  
https://doi.org/10.1007/s00330-013-3007-7</mixed-citation></ref><ref id="scirp.112360-ref31"><label>31</label><mixed-citation publication-type="other" xlink:type="simple">Heywang, S.H., Hahn, D., Schmidt, H., Krischke, I., Eiermann, W., Bassermann, R. and Lissner, J. (1986) MR Imaging of the Breast Using Gadolinium-DTPA. Journal of Computer Assisted Tomography, 10, 199-204.  
https://doi.org/10.1097/00004728-198603000-00005</mixed-citation></ref><ref id="scirp.112360-ref32"><label>32</label><mixed-citation publication-type="other" xlink:type="simple">Heywang-Kobrunner, S.H., Bick, U., Bradley, W.G., Boné, B., Casselman, J., Coulthard, A., Fischer, U., Müller-Schimpfle, M., Oellinger, H., Patt, R., Teubner, J., Friedrich, M., Newstead, G., Holland, R., Schauer, A., Sickles, E.A., Tabar, L., Waisman, J. and Wernecke, K.D. (2001) International Investigation of Breast MRI: Results of a Multicentre Study (11 Sites) Concerning Diagnostic Parameters for Contrast-Enhanced MRI Based on 519 Histopathologically Correlated Lesions. European Radiology, 11, 531-546. https://doi.org/10.1007/s003300000745</mixed-citation></ref><ref id="scirp.112360-ref33"><label>33</label><mixed-citation publication-type="other" xlink:type="simple">Ciatto, S., Houssami, N., Bernardi, D., Caumo, F., Pellegrini, M., Brunelli, S., Tuttobene, P., Bricolo, P., Fantò, C., Valentini, M., Montemezzi, S. and Macaskill, P. (2013) Integration of 3D Digital Mammography with Tomosynthesis for Population Breast-Cancer Screening (STORM): A Prospective Comparison Study. The Lancet Oncology, 14, 583-589. https://doi.org/10.1016/S1470-2045(13)70134-7</mixed-citation></ref><ref id="scirp.112360-ref34"><label>34</label><mixed-citation publication-type="other" xlink:type="simple">Leach, M.O., Boggis, C.R., Dixon, A.K., et al. (2005) Screening with Magnetic Resonance Imaging and Mammography of a UK Population at High Familial Risk of Breast Cancer: A Prospective Multicentre Cohort Study (MARIBS). The Lancet, 365, 1769-1778. https://doi.org/10.1016/S0140-6736(05)66481-1</mixed-citation></ref><ref id="scirp.112360-ref35"><label>35</label><mixed-citation publication-type="other" xlink:type="simple">Kuhl, C.K., Schmutzler, R.K., Leutner, C.C., Kempe, A., Wardelmann, E., Hocke, A., Maringa, M., Pfeifer, U., Krebs, D. and Schild, H.H. (2000) Breast MR Imaging Screening in 192 Women Proved or Suspected to Be Carriers of a Breast Cancer Susceptibility Gene: Preliminary Results. Radiology, 215, 267-279.  
https://doi.org/10.1148/radiology.215.1.r00ap01267</mixed-citation></ref><ref id="scirp.112360-ref36"><label>36</label><mixed-citation publication-type="other" xlink:type="simple">Nystrom, L., Rutqvist, L.E., Wall, S., et al. (1993) Breast Cancer Screening with Mammography: Overview of Swedish Randomised Trials. The Lancet, 341, 973-978. 
https://doi.org/10.1016/0140-6736(93)91067-V</mixed-citation></ref><ref id="scirp.112360-ref37"><label>37</label><mixed-citation publication-type="other" xlink:type="simple">Tabar, L., Fagerberg, G., Duffy, S.W., Day, N.E., et al. (1992) Update of the Swedish Two-County Program of Mammographic Screening for Breast Cancer. Radiologic Clinics of North America, 30, 187-210.</mixed-citation></ref></ref-list></back></article>