<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">OJOph</journal-id><journal-title-group><journal-title>Open Journal of Ophthalmology</journal-title></journal-title-group><issn pub-type="epub">2165-7408</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ojoph.2020.103024</article-id><article-id pub-id-type="publisher-id">OJOph-102311</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Medicine&amp;Healthcare</subject></subj-group></article-categories><title-group><article-title>
 
 
  Evaluation of Mobile Electronic Devices in Detecting Optic Disc and Visual Field Parameters in Patients with Glaucoma at a Tertiary Hospital in Northeastern Tanzania
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Francisco</surname><given-names>Alcides Mulobuana</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Tolbert</surname><given-names>Sonda</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Martin</surname><given-names>M. Rwabilimbo</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>William</surname><given-names>Makupa</given-names></name><xref ref-type="aff" rid="aff4"><sup>4</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Kilimanjaro Christian Medical University College, Moshi, Tanzania</addr-line></aff><aff id="aff3"><addr-line>Department of Epidemiology and Applied Biostatistics, Kilimanjaro Christian Medical College University, Moshi, Tanzania</addr-line></aff><aff id="aff2"><addr-line>Kilimanjaro Clinical Research Institute, Moshi, Tanzania</addr-line></aff><aff id="aff4"><addr-line>Kilimanjaro Christian Medical Centre, Moshi, Tanzania</addr-line></aff><pub-date pub-type="epub"><day>29</day><month>06</month><year>2020</year></pub-date><volume>10</volume><issue>03</issue><fpage>230</fpage><lpage>238</lpage><history><date date-type="received"><day>23,</day>	<month>May</month>	<year>2020</year></date><date date-type="rev-recd"><day>17,</day>	<month>August</month>	<year>2020</year>	</date><date date-type="accepted"><day>20,</day>	<month>August</month>	<year>2020</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Background: Glaucoma is a serious public health problem since it causes visual impairment impacting social, mental and physical health of an individual. Diagnosis and management of glaucoma continue to be a challenge due to few qualified personnel and high cost of the equipment. The use of portable Eye Examination Kit such as Smartphone and tablets can be used in glaucoma screening for taking high-resolution fundus photos for optic disc and visual field parameters, respectively. This study was conducted to evaluate the applicability of mobile electronic device to detect optic disc and visual field parameters for glaucoma in a resource limited setting. 
  Objective: To evaluate the applicability of mobile electronic devices to detect optic disc and visual field parameters for glaucoma. 
  Methodology: Across-sectional study was conducted at KCMC Eye department from October 2018 to June 2019. Study included 140 participants attending eye clinic of which 67 had glaucoma and 73 without glaucoma. Clinical and socio-demographic data were collected using a structured questionnaire and analysed using Stata 15. Glaucoma examination was made on the right eye and photo comparison made between those with and without glaucoma. PEEK Smartphone fundus photo examination was compared with the gold standard machine (Slit Lamp Biomicroscopy), Amsler grid chart installed on a tablet (Microsoft surface, internal storage 256 GB, 2013) and contrast sensitivity compared with Humphrey field analyser (i series, model 740117434, Carl Zeiss Meditec). 
  Results: The kappa (k) agreement between Slit lump biomicroscopy fundus view image and PEEK Smartphone concerning the optic disc measurement was 0.92 with sensitivity and specificity of 90.32% (95% CI: 80.12 - 96.37) and 93.59% (95% CI: 85.67 - 97.89) with a p &lt; 0.001 respectively. An agreement between Amsler grid and Humphrey Field Analyser was 0.67 with sensitivity of 33.33% (95% CI: 20.76 - 47.92) and specificity of 86.52% (95% CI: 77.63 - 92.83) with a p &lt; 0.005. An agreement for contrast sensitivity and Humphrey Field Analyser was 0.51 with sensitivity of 48.91% (95% CI: 38.3 - 59.56) and specificity of 54.17% (95% CI: 39.17 - 68.63) and p value of 0.729. 
  Conclusion: PEEK Smartphone fundus image specificity was almost in perfect agreement compared with Amsler grid and Contrast sensitivity. The PEEK Smartphone fundus view optic disc parameter for vertical cup to disc ratio has a potential to enhance detection of glaucoma and thus improve its management in resource-limited settings.
 
</p></abstract><kwd-group><kwd>Glaucoma</kwd><kwd> PEEK Smartphone</kwd><kwd> Contrast Sensitivity</kwd><kwd> Amsler Grid</kwd><kwd> Kilimanjaro</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Glaucoma is a serious public health problem causing visual impairment, which subsequently impacts social, mental and physical health of an individual. The number of people visually impaired around the world is estimated to be over 200 million; of whom more than 30 million are blind; amongst these, more than 80% are people at middle age and more [<xref ref-type="bibr" rid="scirp.102311-ref1">1</xref>]. Glaucoma is one of the leading causes of blindness and the prevalence in Africa is about 15% with some countries such as Western Cameroon with 8.2%, and those aged 40 years and more were 5.0% in Nigeria and 8.5% in Ghana and in Kenya, according to the same report the prevalence was 4.3% for those aged 50 years and more [<xref ref-type="bibr" rid="scirp.102311-ref2">2</xref>]. In Tanzania having prevalence of all types of glaucoma is 4.16% and the primary open angle glaucoma as the main type [<xref ref-type="bibr" rid="scirp.102311-ref3">3</xref>].</p><p>Early diagnosis for effective detection in high risk populations is crucial to prevent loss of vision related with glaucoma [<xref ref-type="bibr" rid="scirp.102311-ref4">4</xref>]. The gold standard for diagnosing glaucoma is perimetry such as Humphrey field device , but by the time the patients come at the health facilities and these defects detected, the visual loss is already installed and permanent [<xref ref-type="bibr" rid="scirp.102311-ref5">5</xref>]. New technological development of portable devices for glaucoma screening such as Smartphone or tablets is worth exploring. The advantages of these tools are related with their accessibility around the world; convenience, low cost compared with gold standard devices, decreased travel time of the patients to the medical clinics away from their communities for follow up, increased access to specialized care for glaucoma, and decreased patient costs [<xref ref-type="bibr" rid="scirp.102311-ref4">4</xref>]. Smartphones or tablets are handy and can be used for taking high-resolution fundus photos image and help in diagnosing and implement early treatment in patients with glaucoma and thus avoiding blindness in remote or under-serviced communities such as rural or remote areas where there are limited ocular specialists [<xref ref-type="bibr" rid="scirp.102311-ref4">4</xref>].</p><p>This study was conducted to evaluate the applicability of mobile electronic devices to detect optic disc and visual field parameters for glaucoma.</p></sec><sec id="s2"><title>2. Materials and Methods</title><sec id="s2_1"><title>2.1. Study Design and Area</title><p>This was an analytical cross-sectional study for detection of glaucoma; conducted at KCMC Eye Clinic during October 2018 to June 2019. KCMC is a tertiary referral hospital for over 15 million people, which is located in the foothills of Mount Kilimanjaro in Northern Tanzania. The eye department attends more than two thousand patients a year, with an admission service which contains 62 beds and many types of surgery is done in this setting such as glaucoma surgery (e.g. trabeculectomies, goniotomies), ocular plastic surgery, corneal transplant surgery, retinal surgery and many others.</p></sec><sec id="s2_2"><title>2.2. Ethical Considerations</title><p>Ethical approval for this study has been obtained from the KCMU Co Ethical Committee prior to the commencement of this study with certificate number 2321. Permission to conduct this study has been sought from the Director of the hospital and Head of Eye Department. A written informed consent was obtained from each participant or from parents or relatives before enrolment into the study. Confidentiality and privacy of study subjects was maintained by the use of unique identifiers and only the research team had access to data.</p></sec><sec id="s2_3"><title>2.3. Ophthalmological Procedure</title><p>Patients attending Eye clinic at KCMC hospital were conveniently sampled and enrolled into this study and a sample size of adequate sensitivity and a power of 95% confidence interval with the precision of estimate which does not exceed from 7% were used for calculation [<xref ref-type="bibr" rid="scirp.102311-ref6">6</xref>].</p><p>The inclusion criteria was patients above 18 years who consent to participate in the research study, patients with and without glaucoma, patients with refractive error less than +4.75 dioptres and less than −6.0 dioptres and the exclusion criteria was patients with blindness BE and other ocular cormobilities.</p><p>All enrolled patients underwent a medical history, visual acuity by Snellen chart recorded in logMAR, portable Eye examination Kit (PEEK) visual acuity (in logMAR) and contrast sensitivity by Smartphone (SonyExperia, m1, d2403, 2015), Auto refractor and Amsler grid tested on the tablet (Microsoft surface, internal storage 256 GB, 2013) and visual field by Humphrey field (Humphrey field analyzer i series, model 740117434, Carl Zeiss Meditec) was done by a trained personnel who was blinded for glaucoma. After all examination, those participants with and without glaucoma were selected if the vertical cup to disc ratio (VCDR) as less than 0.7 and equal or more than 0.7, visual field within normal limits and outside normal limits, respectively. Also patients with refractive error less than +4.75 diopters and less than −6.0 diopters for spherical and cylindrical were included. For contrast sensitivity, those with equal or less than 2.5% were considered normal and those with more than 2.5% were considered abnormal and the comparison was made with visual field from Humphrey Field Analyser. Amsler grid measured the areas of scotoma, those with no areas of scotoma were considered normal and those with areas of scotoma were considered abnormal and comparison with visual field results 10 - 2 from Humphrey field was made and recorded [<xref ref-type="bibr" rid="scirp.102311-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.102311-ref8">8</xref>].</p></sec><sec id="s2_4"><title>2.4. Statistical Analysis</title><p>All analyses were performed using Stata 15. Descriptive statistics were determined for all demographic and ocular characteristics and presented as proportions. Data for the right eye was chosen for analyses. To compare Smartphone performance with the gold standard tools kappa coefficient of agreement was calculated. We also calculated sensitivity, specificity, positive and negative predictive value of Smartphone in detecting glaucoma.</p></sec></sec><sec id="s3"><title>3. Results</title><sec id="s3_1"><title>3.1. Socio-Demographic and Clinical Characteristics of Study Participants</title><p>A total 140 patients who met the inclusion criteria were included in the analysis (<xref ref-type="table" rid="table1">Table 1</xref>). Out of 140 participants 74 (52.9%) aged 18 - 50 with 74 (52.9%) being female. It was observed that those with normal visual acuity measured by Snellen VA were more predominant 128(91.4%) with the similar results for PEEK visual acuity 129 (92.1%). Refractive error for spherical and cylindrical were evaluated and those scored &lt; +2.00 diopters and those with &lt;−1.5 diopters were 63 (45%) and 96 (68.6%), respectively.</p><p>Intraocular pressure was measured in all participants and found that most of the participants scored normal values in between 9 to 21 mmHg, 1 (0.7%) participants with less than 9 mmHg and 4 (2.9%) with more than 21 mmHg. For contrast sensitivity 92 (65.71%) of the participants scored more than 2.5% and those with no scotoma for Amsler grid were 89 (63.6%). For Amsler grid and Humphrey field severity was 89 (63.6%) and 11 (79.3%) for those with no scotoma, respectively. Participants with less than 0.7 vertical cup to disc ratio were 79 (56.4%) as measured by Smartphone which was similar with the slit lamp measurement of vertical cup to disc ratio in 78 (55.7%) participants.</p><p>According to Humphrey field, participants with within normal limits were 73 (52.14%) compared with those with outside normal limits that were 67 (47.86%). For mean deviation for those with ≤2 dB was 91 (65%).</p></sec><sec id="s3_2"><title>3.2. Comparison between PEEK Smartphone Contrast Sensitivity and Humphrey Visual Field Analyser</title><p>The agreement (k) between PEEK Smartphone contrast sensitivity and Humphrey visual field analyser was 0.51 with p &gt; 0.05 and sensitivity of 48.9% (95%</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Socio-Demographic and clinical characteristics of study participants (N = 140)</title></caption><table><tbody><thead><tr><th align="center" valign="middle" ></th><th align="center" valign="middle" >Characteristics</th><th align="center" valign="middle" >N</th><th align="center" valign="middle" >%</th></tr></thead><tr><td align="center" valign="middle" >Age</td><td align="center" valign="middle" >18 - 50 Above 50</td><td align="center" valign="middle" >74 66</td><td align="center" valign="middle" >52.86 47.14</td></tr><tr><td align="center" valign="middle" >Sex</td><td align="center" valign="middle" >Female Male</td><td align="center" valign="middle" >74 66</td><td align="center" valign="middle" >52.86 47.14</td></tr><tr><td align="center" valign="middle" >Snellen VA</td><td align="center" valign="middle" >≤0.48 LogMAR &gt;0.48 LogMAR</td><td align="center" valign="middle" >128 12</td><td align="center" valign="middle" >91.43 8.57</td></tr><tr><td align="center" valign="middle" >PEEK VA Smartphone</td><td align="center" valign="middle" >≤0.48 LogMAR &gt;0.48 LogMAR</td><td align="center" valign="middle" >129 11</td><td align="center" valign="middle" >92.14 7.86</td></tr><tr><td align="center" valign="middle" >Refractive error spherical</td><td align="center" valign="middle" >&lt;+2.00 diopters +2 to +4.75 diopters ≤ 1.5 diopters −1.5 to −6.0 Error</td><td align="center" valign="middle" >63 4 40 3 30</td><td align="center" valign="middle" >45 2.9 28.6 2.1 21.4</td></tr><tr><td align="center" valign="middle" >Refractive error cylindrical</td><td align="center" valign="middle" >&lt;+2.00 diopters +2 to +4.75 diopters ≤ 1.5 diopters −1.5 to −6.0 Error</td><td align="center" valign="middle" >9 1 96 8 26</td><td align="center" valign="middle" >6.4 0.7 68.6 5.7 18.6</td></tr><tr><td align="center" valign="middle" >IOP</td><td align="center" valign="middle" >&lt;9 mmhg 9 - 21 mmhg &gt;21 mmhg</td><td align="center" valign="middle" >1 135 4</td><td align="center" valign="middle" >0.71 96.43 2.86</td></tr><tr><td align="center" valign="middle" >PEEK Smartphone Contrast sensitivity</td><td align="center" valign="middle" >≤2.5% &gt;2.5%</td><td align="center" valign="middle" >48 92</td><td align="center" valign="middle" >34.28 65.71</td></tr><tr><td align="center" valign="middle" >PEEK Smartphone Amsler grid</td><td align="center" valign="middle" >no scotoma 1 or more scotoma</td><td align="center" valign="middle" >89 51</td><td align="center" valign="middle" >63.57 36.43</td></tr><tr><td align="center" valign="middle" >PEEK Smartphone Amsler grid severity</td><td align="center" valign="middle" >Mild - no scotoma Moderate - one scotona in one quadrant Severe - scotoma in more than one quadrant</td><td align="center" valign="middle" >89 12 39</td><td align="center" valign="middle" >63.6 8.6 27.9</td></tr><tr><td align="center" valign="middle" >PEEK retina smartphone</td><td align="center" valign="middle" >≥0.7 VCDR &lt;0.7 VCDR</td><td align="center" valign="middle" >61 79</td><td align="center" valign="middle" >43.6 56.4</td></tr><tr><td align="center" valign="middle" >Slit lamp biomicroscopy</td><td align="center" valign="middle" >≥0.7 VCDR &lt;0.7 VCDR</td><td align="center" valign="middle" >62 78</td><td align="center" valign="middle" >44.29 55.71</td></tr><tr><td align="center" valign="middle" >Humphrey visual fieldanalyzer</td><td align="center" valign="middle" >Outside normal limits is abnormal Within normal limits is normal</td><td align="center" valign="middle" >67 73</td><td align="center" valign="middle" >47.86 52.14</td></tr><tr><td align="center" valign="middle" >Humphrey visual field analyzer 10 - 2 severity</td><td align="center" valign="middle" >Mild - no scotoma Moderate - one scotona in one quadrant Severe - scotoma in more than one quadrant</td><td align="center" valign="middle" >111 1 28</td><td align="center" valign="middle" >79.3 0.7 20</td></tr><tr><td align="center" valign="middle" >mean deviation</td><td align="center" valign="middle" >≤2 dB abnormal ≥2 dB normal</td><td align="center" valign="middle" >91 49</td><td align="center" valign="middle" >65.00 35.00</td></tr></tbody></table></table-wrap><p>CI: 38.34 - 59.56), specificity of 54.2% (95% CI: 39.17% - 68.63%), positive of 67.2% (95% CI: 54.60 - 78.15) and negative predictive value of 35.6% (95% CI: 24.75 - 47.69) between contrast sensitivity Humphrey visual field analyser (<xref ref-type="table" rid="table2">Table 2</xref>).</p></sec><sec id="s3_3"><title>3.3. Comparison between PEEK Smartphone Amsler Grid and Humphrey Visual Field Analyser</title><p>The agreement (k) between PEEK Smartphone Amsler grid and Humphrey Visual Field Analyser was 0.67with sensitivity and specificity were 33.3% (95% CI: 20.76 - 47.92) and 86.5% (95% CI: 77.63 - 92.83), respectively. Positive and negative predictive values were 58.6% (95% CI: 38.94 - 76.48) and 69.4% (95% CI: 59.91 - 77.77), respectively and p &lt; 0.005 (<xref ref-type="table" rid="table3">Table 3</xref>).</p></sec><sec id="s3_4"><title>3.4. Comparison between PEEK Retina Smartphone and Slit Lamp Biomicroscopy</title><p>The agreement (k) between Smartphone and Slit lamp biomicroscopy was 0.92 with sensitivity and specificity of 90.3% (95% CI: 80.12 - 96.37) and 93.6% (95% CI: 85.67 - 97.89), respectively with p &lt; 0.0001. Positive and negative predictive values were 91.8% (95%CI: 81.90 - 97.28) (<xref ref-type="table" rid="table4">Table 4</xref>).</p><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> PEEK Smartphone Contrast sensitivity and Humphrey visual field analyser (N = 140)</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Test</th><th align="center" valign="middle" >Measures</th><th align="center" valign="middle" >Estimate %</th><th align="center" valign="middle" >95%CI</th><th align="center" valign="middle" >Chi-square P value</th></tr></thead><tr><td align="center" valign="middle"  rowspan="4"  >Contrast sensitivity</td><td align="center" valign="middle" >Sensitivity</td><td align="center" valign="middle" >48.91</td><td align="center" valign="middle" >38.3 - 59.56</td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >Specificity</td><td align="center" valign="middle" >54.17</td><td align="center" valign="middle" >39.17 - 68.63</td><td align="center" valign="middle" >0.1199 &gt; 0.05</td></tr><tr><td align="center" valign="middle" >PPV</td><td align="center" valign="middle" >67.16</td><td align="center" valign="middle" >54.60 - 78.15</td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >NPV</td><td align="center" valign="middle" >35.62</td><td align="center" valign="middle" >24.75 - 47.69</td><td align="center" valign="middle" ></td></tr></tbody></table></table-wrap><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> PEEK Smartphone Amsler grid vs. Humphrey visual field analyzer</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Test</th><th align="center" valign="middle" >Measures</th><th align="center" valign="middle" >Estimate %</th><th align="center" valign="middle" >95%CI</th><th align="center" valign="middle" >Chi-square P value</th></tr></thead><tr><td align="center" valign="middle"  rowspan="4"  >Amsler grid</td><td align="center" valign="middle" >Sensitivity</td><td align="center" valign="middle" >33.33</td><td align="center" valign="middle" >20.76 - 47.92</td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >Specificity</td><td align="center" valign="middle" >86.52</td><td align="center" valign="middle" >77.63 - 92.83</td><td align="center" valign="middle" >7.7785 &lt; 0.005</td></tr><tr><td align="center" valign="middle" >PPV</td><td align="center" valign="middle" >58.62</td><td align="center" valign="middle" >38.94 - 76.48</td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >NPV</td><td align="center" valign="middle" >69.37</td><td align="center" valign="middle" >59.91 - 77.77</td><td align="center" valign="middle" ></td></tr></tbody></table></table-wrap><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> PEEK retina Smartphone f vs. Slit lamp Biomicroscopy</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Test</th><th align="center" valign="middle" >Measures</th><th align="center" valign="middle" >Estimate %</th><th align="center" valign="middle" >95%CI</th><th align="center" valign="middle" >Chi-square P value</th></tr></thead><tr><td align="center" valign="middle"  rowspan="4"  >PEEK Smartphone</td><td align="center" valign="middle" >Sensitivity</td><td align="center" valign="middle" >90.32</td><td align="center" valign="middle" >80.12 - 96.37</td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >Specificity</td><td align="center" valign="middle" >93.59</td><td align="center" valign="middle" >85.67 - 97.89</td><td align="center" valign="middle" >98.9256 &lt; 0.0001</td></tr><tr><td align="center" valign="middle" >PPV</td><td align="center" valign="middle" >91.80</td><td align="center" valign="middle" >81.90 - 97.28</td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >NPV</td><td align="center" valign="middle" >92.41</td><td align="center" valign="middle" >84.20 - 97.16</td><td align="center" valign="middle" ></td></tr></tbody></table></table-wrap></sec></sec><sec id="s4"><title>4. Discussion</title><p>In the present study PEEK Smartphone for vertical cup to disc ratio measurement showed a promising potential to be used for glaucoma screening in LMICs. Smartphone had a strong agreement (92%) with Slit lamp biomicroscopy, which is considered a standard screening tool for glaucoma when optic disc parameters were evaluated. Similar to the current studies, several studies, which implemented Smartphone’s for glaucoma screening, found strong agreement with standard screening tool [<xref ref-type="bibr" rid="scirp.102311-ref9">9</xref>].</p><p>In this study it was also noted that Smartphone agreement (92%) with Slit lamp biomicroscopy was almost the same with that recorded [<xref ref-type="bibr" rid="scirp.102311-ref10">10</xref>].</p><p>The almost same observed agreement between PEEK retinal Smartphone with Slit lamp biomicroscopy in the current study may be due to the quality of image and the almost same sample size.</p><p>This means that Smartphone fundus view can be used for glaucoma as sensitivity and specificity and due to its portability and easy to perform the test.</p><p>A moderate agreement of 0.51 was found in this study for PEEK Smartphone contrast sensitivity compared with the study done in United States of America, Spain and Turkey, respectively [<xref ref-type="bibr" rid="scirp.102311-ref11">11</xref>] [<xref ref-type="bibr" rid="scirp.102311-ref12">12</xref>] [<xref ref-type="bibr" rid="scirp.102311-ref13">13</xref>]. Those studies presented with the similar results due to refractive error and cataract. These results showed that contrast sensitivity may not be used alone to detect glaucoma because even those patients whereby they do not had glaucoma the contrast sensitivity scored more than 2.5%.</p><p>According to the comparison between PEEK Smartphone Amsler grid and Humphrey visual field analyzer (10 - 2), when related with areas of scotoma it was found an agreement of 0.67 which was similar with the study done in United States of America [<xref ref-type="bibr" rid="scirp.102311-ref14">14</xref>]. It was also found that PEEK Smartphone Amsler grid test had lower sensitivity compared with the study done in Switzerland, due to the sample size, severity of the disease and the fact that in the study were associated with wet-related macular generation was studied [<xref ref-type="bibr" rid="scirp.102311-ref15">15</xref>].</p><p>It may not be used to screen for glaucoma on the fact that it can miss to diagnose patients at the early stage of the disease.</p></sec><sec id="s5"><title>5. Limitations</title><p>Some of the pictures from PEEK retina were difficult to evaluate because was not so clear compared with Slit lamp and subjectively were given the results. The auto refractor was giving error for 30 patients.</p></sec><sec id="s6"><title>6. Conclusion</title><p>PEEK Smartphone fundus view image might be a good tool for screening of optic disc parameters of glaucoma. Its sensitivity and specificity in detecting optic disc damage and its low cost, portability and easy to use make it very more useful in LMICs.</p></sec><sec id="s7"><title>Acknowledgements</title><p>I would like to express my gratitude to my supervisors, Light-For-The-World, Sia Mbishi, Erasmo Mlay and Kelvin Mbuya to make this study and paper possible. Thank you for guiding me throughout the write-up of the dissertation manuscript.</p></sec><sec id="s8"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s9"><title>Cite this paper</title><p>Mulobuana, F.A., Sonda, T., Rwabilimbo, M.M. and Makupa, W. (2020) Evaluation of Mobile Electronic Devices in Detecting Optic Disc and Visual Field Parameters in Patients with Glaucoma at a Tertiary Hospital in Northeastern Tanzania. Open Journal of Ophthalmology, 10, 230-238. https://doi.org/10.4236/ojoph.2020.103024</p></sec></body><back><ref-list><title>References</title><ref id="scirp.102311-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Pascolini, D. and Mariotti, S.P.M. (2010) Global Estimates of Visual Impairment. British Journal Ophthalmology.</mixed-citation></ref><ref id="scirp.102311-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Kyari, F., et al. (2018) The Current Status of Glaucoma and Glaucoma Care in Sub-Saharan Africa. Asia-Pacific Journal of Ophthalmology, 7, 375-386.</mixed-citation></ref><ref id="scirp.102311-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Buhrmann, R.R., Quigley, H.A., Barron, Y., West, S.K., Oliva, M.S. and Mmbaga, B.B. (2000) Prevalence of Glaucoma in a Rural East African Population. Investigative Ophthalmology &amp; Visual Science, 41, 40-48.</mixed-citation></ref><ref id="scirp.102311-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Mohammadpour, M., et al. (2017) Smartphones, Tele-Ophthalmology, and Vision 2020. International Journal of Ophthalmology, 10, 1909-1918.</mixed-citation></ref><ref id="scirp.102311-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Medeiros, F. and Alencar, L. (2011) The Role of Standard Automated Perimetry and Newer Functional Methods for Glaucoma Diagnosis and Follow-Up. Indian Journal of Ophthalmology, 59, 53. https://doi.org/10.4103/0301-4738.73694</mixed-citation></ref><ref id="scirp.102311-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Hajian-Tilaki, K. (2014) Sample Size Estimation in Diagnostic Test Studies of Biomedical Informatics. Journal of Biomedical Informatics, 48, 193-204. https://doi.org/10.1016/j.jbi.2014.02.013</mixed-citation></ref><ref id="scirp.102311-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Fellman, R., et al. (2011) Know the New Glaucoma Codes. EyeNet Magazine, 65-66.http://www.aao.org/eyenet/article/know-new-glaucoma-staging-codes?october-2011</mixed-citation></ref><ref id="scirp.102311-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Susanna Jr., R. and Vessani, R.M. (2009) Staging Glaucoma Patient: Why and How? The Open Ophthalmology Journal, 3, 59-64. https://doi.org/10.2174/1874364100903020059</mixed-citation></ref><ref id="scirp.102311-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Russo, A., et al. (2016) Comparison of Smartphone Ophthalmoscopy with Slit-Lamp Biomicroscopy for Grading Vertical Cup-to-Disc Ratio. Journal of Glaucoma, 25, 777-781. https://doi.org/10.1097/IJG.0000000000000499</mixed-citation></ref><ref id="scirp.102311-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Boonarpha, N., et al. (2018) Comparison of Optic Disc Images from Two Smartphone-Based Imaging Systems in Glaucoma Patients and Suspects. Ophthalmology Journal, 1, 1-7.</mixed-citation></ref><ref id="scirp.102311-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Raza, A.S., Cho, J., de Moraes, C.G.V., et al. (2011) Retinal Ganglion Cell Layer Thickness and Local Visual Field Sensitivity in Glaucoma. Archives of Ophthalmology, 129, 1529-1536. https://doi.org/10.1001/archophthalmol.2011.352</mixed-citation></ref><ref id="scirp.102311-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Fuertes, I., et al. (2016) Evaluation of Contrast Sensitivity, Chromatic Vision, and Reading Ability in Patients with Primary Open Angle Glaucoma. Journal of Ophthalmology, 2016, Article ID: 7074016. https://doi.org/10.1155/2016/7074016</mixed-citation></ref><ref id="scirp.102311-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Temel, A. (2008) FACT Contrast Sensitivity as a Diagnostic Tool in Glaucoma FACT Contrast Sensitivity in Glaucoma. International Ophthalmology, 28, 407-412. https://doi.org/10.1007/s10792-007-9169-z</mixed-citation></ref><ref id="scirp.102311-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Su, D., et al. (2015) Efficacy of the Amsler Grid Test in Evaluating Glaucomatous Central Visual Field Defects. Ophthalmology, 123, 737-743.</mixed-citation></ref><ref id="scirp.102311-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Faes, L., et al. (2014) Diagnostic Accuracy of the Amsler Grid and the Preferential Hyperacuity Perimetry in the Screening of Patients with Age-Related Macular Degeneration: Systematic Review and Meta-Analysis. Eye, 28, 788-796. https://doi.org/10.1038/eye.2014.104</mixed-citation></ref></ref-list></back></article>